Biological performance of a bioabsorbable magnesium-magnesium phosphate cement interbody fusion cage in a porcine lumbar interbody fusion model: a feasibility study.

IF 2.6 3区 医学 Q2 CLINICAL NEUROLOGY European Spine Journal Pub Date : 2024-09-01 Epub Date: 2024-07-22 DOI:10.1007/s00586-024-08387-3
Xuxuan Wang, Yabin Zhang, Yiguo Wang, Yihao Liu, Xiucan Li, Zhenchuan Han, Yongfei Zhao, Bo Wang, Jianheng Liu, Runsheng Wang, Keya Mao
{"title":"Biological performance of a bioabsorbable magnesium-magnesium phosphate cement interbody fusion cage in a porcine lumbar interbody fusion model: a feasibility study.","authors":"Xuxuan Wang, Yabin Zhang, Yiguo Wang, Yihao Liu, Xiucan Li, Zhenchuan Han, Yongfei Zhao, Bo Wang, Jianheng Liu, Runsheng Wang, Keya Mao","doi":"10.1007/s00586-024-08387-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of the study was to evaluate the feasibility of a bioabsorbable cage consisting of magnesium and magnesium phosphate cement (MPC) in a porcine lumbar interbody fusion model.</p><p><strong>Methods: </strong>Twelve male Ba-Ma mini pigs underwent lumbar discectomy and fusion with an Mg-MPC cage or a PEEK cage at the L3/L4 and L4/L5 level. Computed tomography (CT) scans were made to evaluate the distractive property by comparing average disc space height (DSH) before and at 6, 12, and 24 weeks after the operation. After the lumbar spines were harvested at 6 or 24 weeks after the operation, micro-CT examination was conducted to analyze the fusion rate, and stiffness of motion segments was investigated through mechanical tests. A histological study was performed to evaluate the tissue type, inflammation, and osteolysis in the intervertebral space.</p><p><strong>Results: </strong>CT scans showed no significant difference between the two groups in average DSH at each time point. Micro-CT scans revealed an equal fusion rate in both groups (0% at 6 weeks, 83.3% at 24 weeks). Both groups showed time-dependent increases in stability, the Mg-MPC cages achieved an inferior stiffness at 6 weeks and a comparable stiffness at 24 weeks. Histologic evaluation showed the presence of newly formed bone in both groups. However, empty spaces were observed at the interface or around the Mg-MPC cages.</p><p><strong>Conclusion: </strong>Compared with the PEEK cages, the Mg-MPC cages achieved comparable distraction, fusion rate, and spinal stability at 24 weeks after the operation. However, due to inferior stiffness at the early stage and fast degradation, further modification of material composition and design are necessary.</p>","PeriodicalId":12323,"journal":{"name":"European Spine Journal","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Spine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00586-024-08387-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of the study was to evaluate the feasibility of a bioabsorbable cage consisting of magnesium and magnesium phosphate cement (MPC) in a porcine lumbar interbody fusion model.

Methods: Twelve male Ba-Ma mini pigs underwent lumbar discectomy and fusion with an Mg-MPC cage or a PEEK cage at the L3/L4 and L4/L5 level. Computed tomography (CT) scans were made to evaluate the distractive property by comparing average disc space height (DSH) before and at 6, 12, and 24 weeks after the operation. After the lumbar spines were harvested at 6 or 24 weeks after the operation, micro-CT examination was conducted to analyze the fusion rate, and stiffness of motion segments was investigated through mechanical tests. A histological study was performed to evaluate the tissue type, inflammation, and osteolysis in the intervertebral space.

Results: CT scans showed no significant difference between the two groups in average DSH at each time point. Micro-CT scans revealed an equal fusion rate in both groups (0% at 6 weeks, 83.3% at 24 weeks). Both groups showed time-dependent increases in stability, the Mg-MPC cages achieved an inferior stiffness at 6 weeks and a comparable stiffness at 24 weeks. Histologic evaluation showed the presence of newly formed bone in both groups. However, empty spaces were observed at the interface or around the Mg-MPC cages.

Conclusion: Compared with the PEEK cages, the Mg-MPC cages achieved comparable distraction, fusion rate, and spinal stability at 24 weeks after the operation. However, due to inferior stiffness at the early stage and fast degradation, further modification of material composition and design are necessary.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
生物可吸收磷酸镁水泥椎间融合笼在猪腰椎椎间融合模型中的生物性能:一项可行性研究。
目的:该研究旨在评估由镁和磷酸镁水泥(MPC)组成的生物可吸收笼在猪腰椎椎间融合模型中的可行性:12头雄性Ba-Ma迷你猪接受了腰椎间盘切除术,并在L3/L4和L4/L5水平使用Mg-MPC骨水泥笼或PEEK骨水泥笼进行融合。通过比较手术前和手术后 6、12 和 24 周的平均椎间盘间隙高度 (DSH),进行计算机断层扫描 (CT) 以评估牵张特性。术后6周或24周摘取腰椎后,进行显微CT检查以分析融合率,并通过机械测试研究运动节段的硬度。组织学研究评估了椎间隙的组织类型、炎症和骨溶解情况:结果:CT 扫描显示,两组患者在每个时间点的平均 DSH 没有明显差异。显微 CT 扫描显示两组的融合率相同(6 周时为 0%,24 周时为 83.3%)。两组的稳定性均随时间而增加,Mg-MPC 骨架在 6 周时的硬度较低,在 24 周时的硬度相当。组织学评估显示,两组都有新形成的骨质。不过,在 Mg-MPC 骨架的界面或周围观察到了空隙:结论:与 PEEK 骨架相比,Mg-MPC 骨架在术后 24 周的牵引力、融合率和脊柱稳定性方面均具有可比性。然而,由于早期刚度较差且降解较快,有必要对材料成分和设计进行进一步修改。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Spine Journal
European Spine Journal 医学-临床神经学
CiteScore
4.80
自引率
10.70%
发文量
373
审稿时长
2-4 weeks
期刊介绍: "European Spine Journal" is a publication founded in response to the increasing trend toward specialization in spinal surgery and spinal pathology in general. The Journal is devoted to all spine related disciplines, including functional and surgical anatomy of the spine, biomechanics and pathophysiology, diagnostic procedures, and neurology, surgery and outcomes. The aim of "European Spine Journal" is to support the further development of highly innovative spine treatments including but not restricted to surgery and to provide an integrated and balanced view of diagnostic, research and treatment procedures as well as outcomes that will enhance effective collaboration among specialists worldwide. The “European Spine Journal” also participates in education by means of videos, interactive meetings and the endorsement of educative efforts. Official publication of EUROSPINE, The Spine Society of Europe
期刊最新文献
Impact of landmark crater creation on improving accuracy of pedicle screw insertion in robot-assisted scoliosis surgery. MRI-based endplate bone quality score independently predicts cage subsidence after anterior cervical corpectomy fusion. Letter to the editor Regarding 'Causal relationship between basal metabolic rate and intervertebral disc degeneration: a Mendelian randomization study' by Liu Z, et al. (Eur Spine J. 2024 Jun 24. Doi: 10.1007/s00586-024-08367-7). Announcements. Answer to the letter to the editor of Z. Feng, et al. concerning "Unilateral versus bilateral pedicle screw fixation with anterior lumbar interbody fusion: a comparison of postoperative outcomes" by Levy HA, et al. (Eur Spine J [2024]: https://doi.org/10.1007/s00586-024-08412-5).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1