{"title":"Is a Pre-Existent Cone-Beam Computed Tomography Able to Detect Metal Dental Posts?","authors":"Michael Solomonov, Avi Hadad, Joe Ben Itzhak, Alex Lvovsky, Hadas Azizi","doi":"10.3390/dj12070229","DOIUrl":null,"url":null,"abstract":"<p><p>(1) Background: In this study, the efficacy of cone-beam computed tomography (CBCT) in detecting dental posts was compared to periapical radiography. (2) Methods: A retrospective evaluation of 53 patients' periapical radiographs and CBCT images was performed. The presence and type of the intra-canal dental post were initially determined on the periapical images (PA) radiographs' examination and were then compared to the observer's ability to detect the dental post on a CBCT image. The effect of the post's type (metal cast or prefabricated) on its detection on CBCT images was determined. (3) Results: 10.5% of teeth that were identified as having a post on a PA radiograph were not identified as having a post on the CBCT examination (<i>p</i> < 0.05). Approximately 17.6% of teeth that were identified as not having a post on a PA radiograph were identified as having a post on the CBCT examination (<i>p</i> < 0.05). Moreover, 16.3% and 50% of teeth with a prefabricated or cast posts on PA radiographs were falsely identified on the CBCT examination, respectively (<i>p</i> < 0.05). (4) Conclusions: A CBCT image is an insufficient tool for the identification of metal prefabricated and cast posts. A PA image is the recommended radiographic tool for achieving information about the post-endodontic restoration status of teeth candidates for endodontic retreatment in patients with a former CBCT scan.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"12 7","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11276458/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj12070229","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
(1) Background: In this study, the efficacy of cone-beam computed tomography (CBCT) in detecting dental posts was compared to periapical radiography. (2) Methods: A retrospective evaluation of 53 patients' periapical radiographs and CBCT images was performed. The presence and type of the intra-canal dental post were initially determined on the periapical images (PA) radiographs' examination and were then compared to the observer's ability to detect the dental post on a CBCT image. The effect of the post's type (metal cast or prefabricated) on its detection on CBCT images was determined. (3) Results: 10.5% of teeth that were identified as having a post on a PA radiograph were not identified as having a post on the CBCT examination (p < 0.05). Approximately 17.6% of teeth that were identified as not having a post on a PA radiograph were identified as having a post on the CBCT examination (p < 0.05). Moreover, 16.3% and 50% of teeth with a prefabricated or cast posts on PA radiographs were falsely identified on the CBCT examination, respectively (p < 0.05). (4) Conclusions: A CBCT image is an insufficient tool for the identification of metal prefabricated and cast posts. A PA image is the recommended radiographic tool for achieving information about the post-endodontic restoration status of teeth candidates for endodontic retreatment in patients with a former CBCT scan.