Detecting Trace Amounts of Peroxides and Ammonium Nitrate in Fingerprints by Ion Mobility Spectrometry

IF 1 4区 化学 Q4 CHEMISTRY, ANALYTICAL Journal of Analytical Chemistry Pub Date : 2024-07-23 DOI:10.1134/s1061934824700357
T. I. Buryakov, I. A. Buryakov
{"title":"Detecting Trace Amounts of Peroxides and Ammonium Nitrate in Fingerprints by Ion Mobility Spectrometry","authors":"T. I. Buryakov, I. A. Buryakov","doi":"10.1134/s1061934824700357","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Abstract</h3><p>The effect of the sweat and grease deposits (SGD) from fingerprints on the detection efficiency of trace amounts of explosive substances—triacetone triperoxide (TATP), hexamethylene triperoxide diamine (HMTD), and ammonium nitrate (AN) by ion mobility spectrometry in air at atmospheric pressure was investigated. Among the main components of SGD, urea is identified as a positive mode influencer, while lactic acid (LA) affects in a negative mode. The presence of urea or SGD in the sample does not significantly affect the detection of TATP in the positive mode but decreases the efficiency of HMTD ion formation and leads to the appearance of adduct cations of HMTD and urea. The presence of lactic acid or SGD slightly decreases the efficiency of ammonium nitrate ion formation in the negative mode and significantly alters the qualitative composition of HMTD ions, leading to the appearance of HMTD and LA adduct anions. In the absence of any impurities in the sample, the best reduced limit of detection (signal-to-noise ratio = 3σ), estimated at 30–50 pg, was observed for HMTD. The lifetime of HMTD, TATP, and AN traces on aluminum foil under laboratory conditions was determined to be 1, 3, and 12 h for samples with masses of <i>m</i><sub>HMTD</sub> 1 × 10<sup>–9</sup>, 2 × 10<sup>–9</sup>, and 1 × 10<sup>–8</sup> g and surface densities <i>d</i><sub>s</sub> of 0.008, 0.016, and 0.08 μg/cm<sup>2</sup>, respectively; 10<sup>2</sup> and 10<sup>3</sup> s for <i>m</i><sub>TATP</sub> 1 × 10<sup>–5</sup> and 1 × 10<sup>–4</sup> g and <i>d</i><sub>s</sub> of 80 and 800 μg/cm<sup>2</sup>, respectively; 12 and 25 h for <i>m</i><sub>AN</sub> 3 × 10<sup>–8</sup> and 5 × 10<sup>–8</sup> g and <i>d</i><sub>s</sub> of 0.24 and 0.4 μg/cm<sup>2</sup>, respectively.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":"37 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1134/s1061934824700357","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The effect of the sweat and grease deposits (SGD) from fingerprints on the detection efficiency of trace amounts of explosive substances—triacetone triperoxide (TATP), hexamethylene triperoxide diamine (HMTD), and ammonium nitrate (AN) by ion mobility spectrometry in air at atmospheric pressure was investigated. Among the main components of SGD, urea is identified as a positive mode influencer, while lactic acid (LA) affects in a negative mode. The presence of urea or SGD in the sample does not significantly affect the detection of TATP in the positive mode but decreases the efficiency of HMTD ion formation and leads to the appearance of adduct cations of HMTD and urea. The presence of lactic acid or SGD slightly decreases the efficiency of ammonium nitrate ion formation in the negative mode and significantly alters the qualitative composition of HMTD ions, leading to the appearance of HMTD and LA adduct anions. In the absence of any impurities in the sample, the best reduced limit of detection (signal-to-noise ratio = 3σ), estimated at 30–50 pg, was observed for HMTD. The lifetime of HMTD, TATP, and AN traces on aluminum foil under laboratory conditions was determined to be 1, 3, and 12 h for samples with masses of mHMTD 1 × 10–9, 2 × 10–9, and 1 × 10–8 g and surface densities ds of 0.008, 0.016, and 0.08 μg/cm2, respectively; 102 and 103 s for mTATP 1 × 10–5 and 1 × 10–4 g and ds of 80 and 800 μg/cm2, respectively; 12 and 25 h for mAN 3 × 10–8 and 5 × 10–8 g and ds of 0.24 and 0.4 μg/cm2, respectively.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用离子迁移谱检测指纹中的微量过氧化物和硝酸铵
摘要 研究了指纹中的汗液和油脂沉积物(SGD)对常压空气中离子迁移谱法检测痕量爆炸性物质--三丙酮三过氧化物(TATP)、六亚甲基三过氧化二胺(HMTD)和硝酸铵(AN)效率的影响。在 SGD 的主要成分中,尿素被确定为正向影响因子,而乳酸(LA)则为负向影响因子。样品中尿素或 SGD 的存在不会明显影响正向模式下 TATP 的检测,但会降低 HMTD 离子形成的效率,并导致 HMTD 和尿素的加合物阳离子的出现。乳酸或 SGD 的存在会略微降低负模式下硝酸铵离子的形成效率,并明显改变 HMTD 离子的定性组成,导致出现 HMTD 和 LA 的加成阴离子。在样品中没有任何杂质的情况下,HMTD 的最佳降低检测限(信噪比 = 3σ)估计为 30-50 pg。在实验室条件下,对于 mHMTD 质量为 1 × 10-9、2 × 10-9 和 1 × 10-8 g 且表面密度 ds 为 0.008、0.016 和 0.08 μg/cm2 ;mTATP 1 × 10-5 和 1 × 10-4 g,ds 分别为 80 和 800 μg/cm2 时,分别为 102 和 103 秒;mAN 3 × 10-8 和 5 × 10-8 g,ds 分别为 0.24 和 0.4 μg/cm2 时,分别为 12 和 25 小时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Analytical Chemistry
Journal of Analytical Chemistry 化学-分析化学
CiteScore
2.10
自引率
9.10%
发文量
146
审稿时长
13 months
期刊介绍: The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.
期刊最新文献
Separation of Chlorogenic Acids and Caffeine on a Diasfer-110-C10CN Stationary Phase Development, Validation, and Quantification of Organic Impurities with Mass Balance in the Levodopa and Benserazide Hydrochloride Pharmaceutical Dosage Form Surface-Assisted Laser Desorption/Ionization of Metal Complexes with Dithizone Determination of Potassium, Neodymium, and Strontium in Solid Solutions in the KNd(SO4)2·H2O–SrSO4·0.5H2O System Using X-Ray Fluorescence Spectrometry Thin-Layer Chromatography of Methylated Derivatives of Linear Alkylbenzene Sulfonates in Water Analysis by Gas Chromatography–Mass Spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1