A novel chemical purification method for accurate Sn isotope measurement by MC-ICP-MS†

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL Journal of Analytical Atomic Spectrometry Pub Date : 2024-07-25 DOI:10.1039/D4JA00015C
Qinyuan Qu, Wengang Liu, Wang Zheng, Benjamin Chetelat, Qingchuan Liu and Jiubin Chen
{"title":"A novel chemical purification method for accurate Sn isotope measurement by MC-ICP-MS†","authors":"Qinyuan Qu, Wengang Liu, Wang Zheng, Benjamin Chetelat, Qingchuan Liu and Jiubin Chen","doi":"10.1039/D4JA00015C","DOIUrl":null,"url":null,"abstract":"<p >The geological and environmental applications of tin (Sn) isotopes have been hindered by the shortcomings of chemical purification, as severe loss of Sn would occur during sample preparation (evaporation and re-dissolution) and column separation, triggering isotope measurement bias. In this study, we develop a novel and robust separation method to purify Sn from natural samples for accurate isotope measurements. The protocol is established by combining two chromatographic columns loaded with AG 1-X8 and AG 50W-X12 resins, and optimizing the sample evaporation and re-dissolution procedures. The method is proven to efficiently eliminate the main interferents such as Ag, Zn, Mo, Cd and Sb and results in low procedural blank (0.54 ± 0.21 ng, <em>n</em> = 3), quantitative recovery (95–102%, <em>n</em> = 32) and good external precision (<em>δ</em><small><sup>120</sup></small>Sn of 0.02–0.04‰, in 55 measurements) for isotope measurement. The protocol is further applied to seven geological and environmental reference materials (BCR-2, BHVO-2, AGV-2, JG-2, AC-E, PACs-2 and GSS 7) and new values are reported for both odd (<em>δ</em><small><sup>119</sup></small>Sn and <em>δ</em><small><sup>117</sup></small>Sn) and even (<em>δ</em><small><sup>120</sup></small>Sn and <em>δ</em><small><sup>122</sup></small>Sn) Sn isotope ratios. This study demonstrates clearly the potential application of our method for studying the geochemical behaviors of Sn and its isotopes in various aspects.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 9","pages":" 2258-2269"},"PeriodicalIF":3.1000,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00015c","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The geological and environmental applications of tin (Sn) isotopes have been hindered by the shortcomings of chemical purification, as severe loss of Sn would occur during sample preparation (evaporation and re-dissolution) and column separation, triggering isotope measurement bias. In this study, we develop a novel and robust separation method to purify Sn from natural samples for accurate isotope measurements. The protocol is established by combining two chromatographic columns loaded with AG 1-X8 and AG 50W-X12 resins, and optimizing the sample evaporation and re-dissolution procedures. The method is proven to efficiently eliminate the main interferents such as Ag, Zn, Mo, Cd and Sb and results in low procedural blank (0.54 ± 0.21 ng, n = 3), quantitative recovery (95–102%, n = 32) and good external precision (δ120Sn of 0.02–0.04‰, in 55 measurements) for isotope measurement. The protocol is further applied to seven geological and environmental reference materials (BCR-2, BHVO-2, AGV-2, JG-2, AC-E, PACs-2 and GSS 7) and new values are reported for both odd (δ119Sn and δ117Sn) and even (δ120Sn and δ122Sn) Sn isotope ratios. This study demonstrates clearly the potential application of our method for studying the geochemical behaviors of Sn and its isotopes in various aspects.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用 MC-ICP-MS 精确测量 Sn 同位素的新型化学纯化方法
长期以来,锡(Sn)同位素的地质和环境应用一直受到化学纯化缺点的阻碍,因为在样品制备(蒸发和再溶解)和色谱柱分离过程中会发生严重的锡损失,从而引发同位素测量偏差。在本研究中,我们开发了一种新颖、稳健的分离方法,从地质样品中提纯硒,以进行精确的同位素测量。通过将装载 AG 1-X8 和 AG 50W-X12 树脂的两个色谱柱结合起来,并优化样品蒸发和再溶解程序,精心制定了分离方案。实践证明,该方法能有效消除主要干扰,如银、锌、钼、镉、锑和有机杂质,并能获得较低的程序空白(0.54ng,n=3)、定量回收率(95-102%,n=32)和良好的同位素测量外部精度(δ120Sn 为 0.03‰,n=64)。该方案成功应用于七种地质和环境标准(BCR-2、BHVO-2、AGV-2、JG-2、AC-E、PACs-2 和 GSS 7),并报告了奇数(δ119Sn 和 δ117Sn)和偶数(δ120Sn 和 δ122Sn)锡同位素比值的新值。这项研究清楚地表明,我们的方法在研究硒及其同位素的生物地球化学行为的各个方面都具有潜在的应用价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
期刊最新文献
Quantitative sizing of microplastics up to 20 µm using ICP-TOFMS. Back cover High-precision Sm isotope analysis by thermal ionisation mass spectrometry for large meteorite samples (>1 g). Laser-induced breakdown spectroscopy (LIBS): calibration challenges, combination with other techniques, and spectral analysis using data science High-precision MC-ICP-MS measurements of Cd isotopes using a novel double spike method without Sn isobaric interference†
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1