{"title":"Experimental Investigation of Evaporation of Methanol and n-Pentane on a Submerged Capillary Structure","authors":"M.Sc. Hendrik Margraf, Univ.-Prof. Dr.-Ing. habil. Andrea Luke","doi":"10.1002/cite.202300205","DOIUrl":null,"url":null,"abstract":"<p>The heat transfer limit of heat pipes is investigated by pool boiling experiments in a standard apparatus with a capillary layer placed on a copper tube. The capillary layer is a hollow cylinder made of bronze with a wall thickness of 2 mm and the test fluids are methanol and <i>n</i>-pentane. The setting is comparable to high-flux tubes already investigated in the literature. In dependence on the heat flux, three to four sections with different characteristics are identified. Compared to plain copper tubes, the heat transfer is partially increased by a factor of 12 until the limit is reached at around 70 kW m<sup>−2</sup>.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cite.202300205","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cite.202300205","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
The heat transfer limit of heat pipes is investigated by pool boiling experiments in a standard apparatus with a capillary layer placed on a copper tube. The capillary layer is a hollow cylinder made of bronze with a wall thickness of 2 mm and the test fluids are methanol and n-pentane. The setting is comparable to high-flux tubes already investigated in the literature. In dependence on the heat flux, three to four sections with different characteristics are identified. Compared to plain copper tubes, the heat transfer is partially increased by a factor of 12 until the limit is reached at around 70 kW m−2.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.