{"title":"Energy Performance Indicators for Air-Conditioned Museums in Tropical Climates","authors":"Elena Lucchi","doi":"10.3390/buildings14082301","DOIUrl":null,"url":null,"abstract":"The energy design of museums in developing countries is a subject that has been poorly studied, despite its significant implications for heritage preservation, human comfort, energy efficiency, and environmental sustainability. This study introduces a comprehensive framework of Energy Performance Indicators tailored to air-conditioned museums in tropical regions, which represent the most prevalent museum type. These indicators are particularly important as international standards may not be applicable in these contexts. A comprehensive review of the factors and their design implications is provided at the building, system, and component levels. Efficient integration of lighting and air conditioning systems can optimize energy use while maintaining appropriate conditions for both artefact preservation and visitor comfort. Parameters such as average illuminance, uniformity of lighting, lighting power density and lighting energy use intensity are critical in balancing visual quality and energy efficiency. Recommended values and strategies, such as the use of LED lighting and daylight harvesting, help to minimize energy consumption. In addition, parameters such as power density and energy use intensity of air conditioning systems are essential for assessing their efficiency. Techniques such as the integration of solar-assisted, optimized performance indices can effectively reduce energy consumption. Synthetic indicators for assessing lighting quality and overall energy performance are (i) Average Illuminance Ratio, which assesses the adequacy of lighting in a space by comparing the average measured illuminance with the recommended illuminance levels for that space, and (ii) Energy Use Intensity, which represents the total annual energy consumption per unit area of conditioned space. By adopting these indicators, tropical museums can advance energy efficiency and broader sustainability objectives, taking a significant step towards a more energy-conscious and sustainable future.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Buildings","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/buildings14082301","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The energy design of museums in developing countries is a subject that has been poorly studied, despite its significant implications for heritage preservation, human comfort, energy efficiency, and environmental sustainability. This study introduces a comprehensive framework of Energy Performance Indicators tailored to air-conditioned museums in tropical regions, which represent the most prevalent museum type. These indicators are particularly important as international standards may not be applicable in these contexts. A comprehensive review of the factors and their design implications is provided at the building, system, and component levels. Efficient integration of lighting and air conditioning systems can optimize energy use while maintaining appropriate conditions for both artefact preservation and visitor comfort. Parameters such as average illuminance, uniformity of lighting, lighting power density and lighting energy use intensity are critical in balancing visual quality and energy efficiency. Recommended values and strategies, such as the use of LED lighting and daylight harvesting, help to minimize energy consumption. In addition, parameters such as power density and energy use intensity of air conditioning systems are essential for assessing their efficiency. Techniques such as the integration of solar-assisted, optimized performance indices can effectively reduce energy consumption. Synthetic indicators for assessing lighting quality and overall energy performance are (i) Average Illuminance Ratio, which assesses the adequacy of lighting in a space by comparing the average measured illuminance with the recommended illuminance levels for that space, and (ii) Energy Use Intensity, which represents the total annual energy consumption per unit area of conditioned space. By adopting these indicators, tropical museums can advance energy efficiency and broader sustainability objectives, taking a significant step towards a more energy-conscious and sustainable future.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
热带气候下空调博物馆的能效指标
尽管发展中国家博物馆的能源设计对遗产保护、人类舒适度、能源效率和环境可持续性有着重要影响,但对这一问题的研究却很少。本研究针对热带地区最常见的空调型博物馆,提出了一套全面的能源性能指标框架。这些指标尤为重要,因为国际标准可能不适用于这些情况。本文从建筑、系统和组件三个层面对这些因素及其对设计的影响进行了全面评述。照明和空调系统的有效整合可以优化能源使用,同时保持文物保护和游客舒适度的适当条件。平均照度、照明均匀度、照明功率密度和照明能源使用强度等参数对于平衡视觉质量和能源效率至关重要。推荐的数值和策略,如使用 LED 照明和日光采集,有助于最大限度地降低能耗。此外,空调系统的功率密度和能源使用强度等参数对于评估其效率也至关重要。整合太阳能辅助优化性能指标等技术可以有效降低能耗。用于评估照明质量和整体能效的合成指标有:(i) 平均照度比,通过比较测量的平均照度和建议的空间照度水平,评估空间照明的充足程度;(ii) 能源使用强度,表示空调空间单位面积的年度总能耗。通过采用这些指标,热带博物馆可以提高能源效率,实现更广泛的可持续发展目标,向更具能源意识和可持续发展的未来迈出重要一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Buildings
Buildings Multiple-
CiteScore
3.40
自引率
26.30%
发文量
1883
审稿时长
11 weeks
期刊介绍: BUILDINGS content is primarily staff-written and submitted information is evaluated by the editors for its value to the audience. Such information may be used in articles with appropriate attribution to the source. The editorial staff considers information on the following topics: -Issues directed at building owners and facility managers in North America -Issues relevant to existing buildings, including retrofits, maintenance and modernization -Solution-based content, such as tips and tricks -New construction but only with an eye to issues involving maintenance and operation We generally do not review the following topics because these are not relevant to our readers: -Information on the residential market with the exception of multifamily buildings -International news unrelated to the North American market -Real estate market updates or construction updates
期刊最新文献
Behavior of Lightweight Self-Compacting Concrete with Recycled Tire Steel Fibers Examination of the Release of Heavy Metals from Self-Hardening Slurries with Fly Ash from Municipal Sewage Sludge Incineration, Considering the Character of Its Operation in a Cut-Off Wall Evaluating the Impact of CO2 on Calcium SulphoAluminate (CSA) Concrete Exploring the Readiness of Organisations to Adopt Artificial Intelligence Impact of Night Ventilation on Indoor Thermal Environment of Residential Buildings under the Dual Carbon Target: A Case Study of Xi’an
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1