{"title":"Research on the Performance and Computational Fluid Dynamics Numerical Simulation of Plate Air Gap Membrane Distillation Module","authors":"Haojie Bi, Hongying Yuan, Zhiyuan Xu, Zhuobin Liang, Yongliang Du","doi":"10.3390/membranes14080162","DOIUrl":null,"url":null,"abstract":"Membrane distillation (MD) is widely used in the field of seawater desalination. Among its various sub-categories, air gap membrane distillation (AGMD) stands out due to its high thermal efficiency and compatibility with low-grade heat sources. This study delves into the impact of varying operating conditions on AGMD performance, employing numerical simulations which are grounded in experimental validation. The objective was to enhance the performance of AGMD, mitigate polarization phenomena, and provide a reference for optimizing membrane component design. The results show that the agreements between the simulated and the experimental values were high. When increasing the feed temperature and decreasing the coolant temperature, the impact of polarization phenomena on the performance of AGMD was reduced. The mass flux, Total Permeate Concentration (TPC), and heat flux increased by 81.69%, 36.89%, and 118.01%, respectively, when the feed temperature was increased from 50 °C to 75 °C. When the coolant temperature decreased from 22 °C to 7 °C, the mass flux increased by 37.06%. The response surface analysis revealed that the feed temperature has significant influence on AGMD performance, and there is a noticeable interaction between the feed temperature and coolant temperature. These findings will play key roles in practical applications.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"21 4","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/membranes14080162","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Membrane distillation (MD) is widely used in the field of seawater desalination. Among its various sub-categories, air gap membrane distillation (AGMD) stands out due to its high thermal efficiency and compatibility with low-grade heat sources. This study delves into the impact of varying operating conditions on AGMD performance, employing numerical simulations which are grounded in experimental validation. The objective was to enhance the performance of AGMD, mitigate polarization phenomena, and provide a reference for optimizing membrane component design. The results show that the agreements between the simulated and the experimental values were high. When increasing the feed temperature and decreasing the coolant temperature, the impact of polarization phenomena on the performance of AGMD was reduced. The mass flux, Total Permeate Concentration (TPC), and heat flux increased by 81.69%, 36.89%, and 118.01%, respectively, when the feed temperature was increased from 50 °C to 75 °C. When the coolant temperature decreased from 22 °C to 7 °C, the mass flux increased by 37.06%. The response surface analysis revealed that the feed temperature has significant influence on AGMD performance, and there is a noticeable interaction between the feed temperature and coolant temperature. These findings will play key roles in practical applications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
板式气隙膜蒸馏组件的性能与计算流体力学数值模拟研究
膜蒸馏(MD)广泛应用于海水淡化领域。在其各个子类别中,气隙膜蒸馏(AGMD)因其热效率高且与低品位热源兼容而脱颖而出。本研究通过以实验验证为基础的数值模拟,深入探讨了不同操作条件对 AGMD 性能的影响。目的是提高 AGMD 的性能,缓解极化现象,并为优化膜组件设计提供参考。结果表明,模拟值与实验值的一致性很高。当提高进料温度和降低冷却剂温度时,极化现象对 AGMD 性能的影响减小。当进料温度从 50 °C 升至 75 °C 时,质量通量、总渗透浓度(TPC)和热通量分别增加了 81.69%、36.89% 和 118.01%。当冷却剂温度从 22 °C 降至 7 °C 时,质量通量增加了 37.06%。响应面分析表明,进料温度对 AGMD 性能有显著影响,而且进料温度与冷却剂温度之间存在明显的交互作用。这些发现将在实际应用中发挥关键作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊介绍: ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric. Indexed/​Abstracted: Web of Science SCIE Scopus CAS INSPEC Portico
期刊最新文献
Issue Editorial Masthead Issue Publication Information Marking the 100th Issue of ACS Applied Electronic Materials Pushing down the Limit of Ammonia Detection of ZnO-Based Chemiresistive Sensors with Exposed Hexagonal Facets at Room Temperature Direct-Printed Mn–Ni–Cu–O/Poly(vinyl butyral) Composites for Sintering-Free, Flexible Thermistors with High Sensitivity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1