Transapical off-pump implantation of artificial mitral neochords in a patient after Bentall procedure - case report

Bogumił Bocianiak, Paulina Krzemińska, Kacper Kranc, Dominika Munzberger, Damian Ruta, Laura Hamerska, Julia Hamerska, Joanna Antczak, Julia Lipska, Urszula Fenrych, Karolina Wojtczak, Olga Skupińska, Anna Kajka
{"title":"Transapical off-pump implantation of artificial mitral neochords in a patient after Bentall procedure - case report","authors":"Bogumił Bocianiak, Paulina Krzemińska, Kacper Kranc, Dominika Munzberger, Damian Ruta, Laura Hamerska, Julia Hamerska, Joanna Antczak, Julia Lipska, Urszula Fenrych, Karolina Wojtczak, Olga Skupińska, Anna Kajka","doi":"10.12775/qs.2024.17.53148","DOIUrl":null,"url":null,"abstract":"The NeoChord DS 1000 system offers a minimally invasive alternative for treating degenerative mitral regurgitation (MR), particularly in high-risk patients with previous aortic surgery. A 74-year-old male with a history of Bentall procedure presented with severe MR and dyspnea (NYHA III). Transapical mitral valve repair was performed using the NeoChord DS 1000 system. Three artificial chordae were implanted, significantly reducing MR. The patient had an uneventful recovery and was discharged in good condition after 8 days. \nThis case demonstrates the NeoChord system's potential in high-risk patients where traditional MVR poses high risks. Transapical access avoids sternotomy and extracorporeal circulation, offering a safer alternative. The NeoChord DS 1000 system shows promise for high-risk patients and those with complex surgical histories, though further research is needed to confirm its long-term efficacy and durability.","PeriodicalId":431915,"journal":{"name":"Quality in Sport","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quality in Sport","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12775/qs.2024.17.53148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The NeoChord DS 1000 system offers a minimally invasive alternative for treating degenerative mitral regurgitation (MR), particularly in high-risk patients with previous aortic surgery. A 74-year-old male with a history of Bentall procedure presented with severe MR and dyspnea (NYHA III). Transapical mitral valve repair was performed using the NeoChord DS 1000 system. Three artificial chordae were implanted, significantly reducing MR. The patient had an uneventful recovery and was discharged in good condition after 8 days. This case demonstrates the NeoChord system's potential in high-risk patients where traditional MVR poses high risks. Transapical access avoids sternotomy and extracorporeal circulation, offering a safer alternative. The NeoChord DS 1000 system shows promise for high-risk patients and those with complex surgical histories, though further research is needed to confirm its long-term efficacy and durability.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
为一名 Bentall 手术后的患者实施经皮腔外人工二尖瓣新骨植入术 - 病例报告
NeoChord DS 1000 系统是治疗退行性二尖瓣反流(MR)的微创替代方案,尤其适用于曾接受过主动脉手术的高危患者。一位 74 岁的男性患者曾接受过 Bentall 手术,并伴有严重的二尖瓣反流和呼吸困难(NYHA III)。使用 NeoChord DS 1000 系统进行了经心尖二尖瓣修复术。植入了三个人工腱膜,大大减少了 MR。患者恢复顺利,8 天后康复出院。该病例证明了 NeoChord 系统在传统 MVR 存在高风险的高危患者中的潜力。经心尖入路避免了胸骨切开术和体外循环,提供了更安全的选择。NeoChord DS 1000 系统为高风险患者和有复杂手术史的患者带来了希望,尽管还需要进一步的研究来确认其长期疗效和耐用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The influence of air pollution on asthma in athletes – a brief review of the literature Beyond Pills: Synergizing Pharmacological and Physical Activity Interventions in Fibromyalgia Treatment. A review influence of physical activity on the health and treatment of schizophrenia patients Dangers in the use of systemic and local drugs expressed in eye disorders – a literature review High-Intensity Interval Training - health benefits and risks - literature review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1