Study on the Bearing Capacity of the Polyethylene Pipe–Cured-In-Place Pipe Liner Composite Structure under External Pressure

IF 4.7 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-07-22 DOI:10.3390/buildings14072253
Xinyi Wang, Cong Zeng, Xuefeng Yan, Peng Zhang
{"title":"Study on the Bearing Capacity of the Polyethylene Pipe–Cured-In-Place Pipe Liner Composite Structure under External Pressure","authors":"Xinyi Wang, Cong Zeng, Xuefeng Yan, Peng Zhang","doi":"10.3390/buildings14072253","DOIUrl":null,"url":null,"abstract":"Cured-in-place pipe (CIPP) technology is used to repair deformed municipal polyethylene (PE) pipes caused by design flaws, construction issues, or external loads. However, research on CIPP for PE pipes is limited, restricting its broader application. This research focuses on the mechanical response characteristics and failure modes of the composite PE pipe–CIPP liner structure under external loads. Using experimental setups involving comparative test groups with different diameters and wall thickness ratios (DR values, defined as the ratio of the pipe’s outer diameter to its wall thickness), this study evaluates the effects of the liner’s elastic modulus, the bonding effectiveness at the PE pipe–CIPP liner interface, and the initial ovality of the pipes on the load-bearing capacity. The experimental results reveal that CIPP liners substantially enhance the stiffness and load-bearing capacity of PE pipes, with improvements ranging from 200% to nearly 500% depending on the pipe’s DR value. A novel ring stiffness prediction model is also introduced and validated against the experimental data. This model provides a theoretical framework for understanding the complex interactions at the PE pipe–CIPP liner interface and aids in designing more resilient urban drainage systems.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"21 17","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/buildings14072253","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Cured-in-place pipe (CIPP) technology is used to repair deformed municipal polyethylene (PE) pipes caused by design flaws, construction issues, or external loads. However, research on CIPP for PE pipes is limited, restricting its broader application. This research focuses on the mechanical response characteristics and failure modes of the composite PE pipe–CIPP liner structure under external loads. Using experimental setups involving comparative test groups with different diameters and wall thickness ratios (DR values, defined as the ratio of the pipe’s outer diameter to its wall thickness), this study evaluates the effects of the liner’s elastic modulus, the bonding effectiveness at the PE pipe–CIPP liner interface, and the initial ovality of the pipes on the load-bearing capacity. The experimental results reveal that CIPP liners substantially enhance the stiffness and load-bearing capacity of PE pipes, with improvements ranging from 200% to nearly 500% depending on the pipe’s DR value. A novel ring stiffness prediction model is also introduced and validated against the experimental data. This model provides a theoretical framework for understanding the complex interactions at the PE pipe–CIPP liner interface and aids in designing more resilient urban drainage systems.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
外压下聚乙烯管道-就地固化管道内衬复合结构的承载能力研究
就地固化管道(CIPP)技术可用于修复因设计缺陷、施工问题或外部负载而导致变形的市政聚乙烯(PE)管道。然而,有关聚乙烯管材 CIPP 的研究十分有限,限制了其更广泛的应用。本研究的重点是聚乙烯管材-CIPP 复合内衬结构在外部荷载作用下的机械响应特性和失效模式。本研究利用不同直径和壁厚比(DR 值,定义为管材外径与壁厚之比)的对比试验组进行实验设置,评估了衬垫的弹性模量、聚乙烯管材-CIPP 衬垫界面的粘合效果以及管材的初始椭圆度对承载能力的影响。实验结果表明,CIPP 衬里可大幅提高聚乙烯管材的刚度和承载能力,根据管材的 DR 值,提高幅度从 200% 到近 500%。此外,还介绍了一种新型环刚度预测模型,并根据实验数据进行了验证。该模型为理解聚乙烯管材-CIPP 内衬管界面的复杂相互作用提供了一个理论框架,有助于设计更具弹性的城市排水系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊介绍: ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric. Indexed/​Abstracted: Web of Science SCIE Scopus CAS INSPEC Portico
期刊最新文献
Issue Publication Information Issue Editorial Masthead Corroborating the Monro-Kellie Principles. High-Performance Flexible Strain Sensor Enhanced by Functionally Partitioned Conductive Network for Intelligent Monitoring of Human Activities Carbon Nanotube-Enhanced Liquid Metal Composite Ink for Strain Sensing and Digital Recognition
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1