Stability‐Indicating HPLC Method Development and Validation for the Quantification of Tofacitinib Citrate and Its Related Substances Using Hydrophilic Liquid Interaction Chromatography

IF 1.3 Q4 CHEMISTRY, ANALYTICAL SEPARATION SCIENCE PLUS Pub Date : 2024-07-16 DOI:10.1002/sscp.202400048
G. Sivaprasadu, Muralidhar Pamerla, Podilapu Atchutha Rao, Adapa Venkateswara Rao, Suresh Salakolusu, Harihara Padhy, Ravikumar Ganta
{"title":"Stability‐Indicating HPLC Method Development and Validation for the Quantification of Tofacitinib Citrate and Its Related Substances Using Hydrophilic Liquid Interaction Chromatography","authors":"G. Sivaprasadu, Muralidhar Pamerla, Podilapu Atchutha Rao, Adapa Venkateswara Rao, Suresh Salakolusu, Harihara Padhy, Ravikumar Ganta","doi":"10.1002/sscp.202400048","DOIUrl":null,"url":null,"abstract":"A new stability‐indicating RPHPLC method with short run time has been developed and validated for tofacitinib citrate and its related substances. The novel HPLC method integrates hydrophilic interaction liquid chromatography (HILIC) technology as the stationary phase and employs a mobile phase composed of phosphate buffer (pH 7.0) and acetonitrile (45:55, %v/v) at a flow rate of 0.5 mL/min under isocratic elution. Analytes were monitored via a UV detector at 210 nm and with the column oven temperature at 30°C for a 20‐min analysis. Precision (%RSD) for Impurity‐A and Impurity‐B and tofacitinib met specifications at 2.4%, 0.8%, and 0.0%, respectively. Accuracy ranged from 86% to 100% for impurities, with LOD at 0.03% and LOQ at 0.05%–0.06%. Correlation coefficients exceeded 0.999 for impurities and tofacitinib citrate. Solution stability was confirmed for 24 h at room temperature. The method range was extended from LOQ to ∼1.5% for impurities and LOQ to ∼150% for tofacitinib citrate. The method's stability was evaluated under acid and base hydrolysis, oxidative and water hydrolysis, and thermal and photolytic degradation. Introducing HILIC as the stationary phase for this work proved effective, eliminating the need of ion pair reagents, reducing analysis time, and ensuring consistent results.","PeriodicalId":21639,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202400048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A new stability‐indicating RPHPLC method with short run time has been developed and validated for tofacitinib citrate and its related substances. The novel HPLC method integrates hydrophilic interaction liquid chromatography (HILIC) technology as the stationary phase and employs a mobile phase composed of phosphate buffer (pH 7.0) and acetonitrile (45:55, %v/v) at a flow rate of 0.5 mL/min under isocratic elution. Analytes were monitored via a UV detector at 210 nm and with the column oven temperature at 30°C for a 20‐min analysis. Precision (%RSD) for Impurity‐A and Impurity‐B and tofacitinib met specifications at 2.4%, 0.8%, and 0.0%, respectively. Accuracy ranged from 86% to 100% for impurities, with LOD at 0.03% and LOQ at 0.05%–0.06%. Correlation coefficients exceeded 0.999 for impurities and tofacitinib citrate. Solution stability was confirmed for 24 h at room temperature. The method range was extended from LOQ to ∼1.5% for impurities and LOQ to ∼150% for tofacitinib citrate. The method's stability was evaluated under acid and base hydrolysis, oxidative and water hydrolysis, and thermal and photolytic degradation. Introducing HILIC as the stationary phase for this work proved effective, eliminating the need of ion pair reagents, reducing analysis time, and ensuring consistent results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
亲水液体相互作用色谱法定量枸橼酸托法替尼及其相关物质的稳定性指示高效液相色谱法的开发与验证
针对枸橼酸托法替尼及其相关物质开发并验证了一种运行时间短的新型稳定性指示RPHPLC方法。该新型高效液相色谱法采用亲水相互作用液相色谱(HILIC)技术作为固定相,以磷酸盐缓冲液(pH 7.0)和乙腈(45:55, %v/v)为流动相,流速为0.5 mL/min,等度洗脱。通过 210 nm 波长的紫外检测器对分析物进行监测,柱温为 30°C,分析时间为 20 分钟。杂质-A、杂质-B 和托法替尼的精密度(%RSD)分别为 2.4%、0.8% 和 0.0%,符合规范要求。杂质的准确度从 86% 到 100% 不等,LOD 为 0.03%,LOQ 为 0.05%-0.06%。杂质与枸橼酸托法替尼的相关系数超过 0.999。室温下 24 小时的溶液稳定性得到确认。杂质的方法定量范围为LOQ~1.5%,枸橼酸托法替尼的方法定量范围为LOQ~150%。在酸和碱水解、氧化和水分解、热降解和光降解条件下对该方法的稳定性进行了评价。在这项工作中采用 HILIC 作为固定相证明是有效的,无需离子对试剂,缩短了分析时间,并确保了结果的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
SEPARATION SCIENCE PLUS
SEPARATION SCIENCE PLUS CHEMISTRY, ANALYTICAL-
CiteScore
1.90
自引率
9.10%
发文量
111
期刊最新文献
Removal of Residual DNA and Host Cell Proteins for the Purification of Recombinant Staphylokinase Expressed in Escherichia coli Green Analytical Approach for HPLC Method Development for Quantification of Sorafenib and Its Pharmacopeia Impurities: LC–MS/MS Characterization and Toxicity Prediction of Stress Degradation Products A Cartridge Structure Facilitates Clinical Mass Spectrometry Pretreatment and Can be Integrated Into a High‐Throughput Instrument Comparison of Polysaccharide Profiles of Different Seaweeds Based on Ion Chromatography and Ultrahigh‐Performance Liquid Chromatography Quantification of Recycled Polypropylene Stabilizers for Quality Control by Liquid Chromatography–Tandem Mass Spectrometry Using Simple, Fast and Efficient Ultrasonic Extraction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1