3D printing and CBCT anatomical reproducibility assessment in forensic scenarios

IF 1.2 4区 医学 Q3 MEDICINE, LEGAL Journal of forensic and legal medicine Pub Date : 2024-08-01 DOI:10.1016/j.jflm.2024.102719
{"title":"3D printing and CBCT anatomical reproducibility assessment in forensic scenarios","authors":"","doi":"10.1016/j.jflm.2024.102719","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>The scientific community highlighted the relevance of 3D physical models since the beginning of the XXI century, complementary to three-dimensional(3D) digital volume by computer tomography, to support court discussions on medico-legal issues. The recreation of 3D evidence can be an important tool for investigators and experts, providing a better understanding of the causes and circumstances of the events involved in a crime.</p></div><div><h3>Objective</h3><p>The present study aims to assess the reproducibility of 3D printed and 3D tomographic volumes generated from mandibles following simulated forensic injuries, highlighting the recreation of crime tools.</p></div><div><h3>Material and methods</h3><p>Concerning the study design presented, data collection was performed in three phases. Nine simulated injuries of forensic interest were selected (phase1) and all the mandibles were scanned tomographically, individually, by Cone Beam Computed Tomography CBCT (phase 2). Then, in phase 3, the DICOM images were used for 3D printing with the Ender 3® printer by the Fused Deposition Modeling (FDM) technique. The data analysis followed two procedures: the comparison between the artificial mandible and 3D tomographic volume (AT) and the comparison between the artificial mandible and 3D printed volume, or the copy (AC). Data were analyzed using T-Student and ICC tests and presented in Bland-Altman plots.</p></div><div><h3>Conclusion</h3><p>The analogic technique applied in 3D printed volume, when compared with computerized technique, using 3D digital images and measurement, showed to be accurate and reproducible. Further studies are needed in search of standardization for three-dimensional measurements in digitized and printed volumes.</p></div>","PeriodicalId":16098,"journal":{"name":"Journal of forensic and legal medicine","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of forensic and legal medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1752928X24000817","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

The scientific community highlighted the relevance of 3D physical models since the beginning of the XXI century, complementary to three-dimensional(3D) digital volume by computer tomography, to support court discussions on medico-legal issues. The recreation of 3D evidence can be an important tool for investigators and experts, providing a better understanding of the causes and circumstances of the events involved in a crime.

Objective

The present study aims to assess the reproducibility of 3D printed and 3D tomographic volumes generated from mandibles following simulated forensic injuries, highlighting the recreation of crime tools.

Material and methods

Concerning the study design presented, data collection was performed in three phases. Nine simulated injuries of forensic interest were selected (phase1) and all the mandibles were scanned tomographically, individually, by Cone Beam Computed Tomography CBCT (phase 2). Then, in phase 3, the DICOM images were used for 3D printing with the Ender 3® printer by the Fused Deposition Modeling (FDM) technique. The data analysis followed two procedures: the comparison between the artificial mandible and 3D tomographic volume (AT) and the comparison between the artificial mandible and 3D printed volume, or the copy (AC). Data were analyzed using T-Student and ICC tests and presented in Bland-Altman plots.

Conclusion

The analogic technique applied in 3D printed volume, when compared with computerized technique, using 3D digital images and measurement, showed to be accurate and reproducible. Further studies are needed in search of standardization for three-dimensional measurements in digitized and printed volumes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
法医场景中的 3D 打印和 CBCT 解剖再现性评估
导言自二十一世纪初以来,科学界就强调了三维物理模型的相关性,它是计算机断层扫描技术对三维(3D)数字体积的补充,可支持法庭对医学法律问题的讨论。本研究旨在评估模拟法医损伤后从下颌骨生成的三维打印体积和三维断层扫描体积的再现性,突出强调犯罪工具的再现。选取了九个法医感兴趣的模拟损伤(第一阶段),并通过锥形束计算机断层扫描 CBCT 对所有下颌骨进行单独断层扫描(第二阶段)。然后,在第 3 阶段,利用 DICOM 图像通过熔融沉积建模(FDM)技术,使用 Ender 3® 打印机进行 3D 打印。数据分析遵循两个程序:人工下颌骨与三维断层扫描体积(AT)的比较,以及人工下颌骨与三维打印体积或副本(AC)的比较。使用 T-Student 和 ICC 检验对数据进行分析,并以 Bland-Altman 图的形式显示。结论三维打印体积中应用的模拟技术与使用三维数字图像和测量的计算机技术相比,显示出其准确性和可重复性。需要进一步研究数字化和打印体积的三维测量标准化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.70
自引率
6.70%
发文量
106
审稿时长
57 days
期刊介绍: The Journal of Forensic and Legal Medicine publishes topical articles on aspects of forensic and legal medicine. Specifically the Journal supports research that explores the medical principles of care and forensic assessment of individuals, whether adult or child, in contact with the judicial system. It is a fully peer-review hybrid journal with a broad international perspective. The Journal accepts submissions of original research, review articles, and pertinent case studies, editorials, and commentaries in relevant areas of Forensic and Legal Medicine, Context of Practice, and Education and Training. The Journal adheres to strict publication ethical guidelines, and actively supports a culture of inclusive and representative publication.
期刊最新文献
Ethyl alcohol consumption characteristics of deceased individuals in Lithuania Biochemical analysis of vitreous humor and synovial fluid in the estimation of early postmortem interval: A meta-analytical approach Review of nine malpractice cases with allegations of causation of cervical artery dissection by cervical spine manipulation: No evidence for causation Xylazine abuse, the growing risk: A review of its effects, upsurge use and associated fatalities in the USA and Puerto Rico Common errors in the completion of death certificates in teaching hospitals in northern Iran: A legal challenge
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1