The association of P2 and lean % estimates from commercial measurement systems with computed tomography determined composition within Australian pork abattoirs
F. Anderson , M.T. Corlett , A. Williams , S. Sterndale , M. Trezona , G.E. Gardner
{"title":"The association of P2 and lean % estimates from commercial measurement systems with computed tomography determined composition within Australian pork abattoirs","authors":"F. Anderson , M.T. Corlett , A. Williams , S. Sterndale , M. Trezona , G.E. Gardner","doi":"10.1016/j.meatsci.2024.109612","DOIUrl":null,"url":null,"abstract":"<div><p>Pork carcasses were obtained from three abattoirs in Australia (<em>n</em> = 345) where technologies enabled collection of post slaughter measures of P2 fat depth (mm) (Hennessy Grading Probe (HGP), AutoFom III, PorkScan Lite) and estimates of carcass lean % (HGP, AutoFom III, PorkScan Plus). Computed tomography (CT) was used to scan carcasses and determine lean and fat %, with the strength of associations with abattoir measurement devices determined. The AutoFom III lean % demonstrated the strongest associations with whole carcass CT lean % (R<sup>2</sup> 0.63, RMSE 1.73) and fat % (R<sup>2</sup> 0.68, RMSE 1.80) and with section (fore, loin, belly and hind) CT composition. The association of P2 from AutoFom III was lower in comparison, however remained superior to other commercial devices (PorkScan Lite and HGP). Porkscan Plus lean % demonstrated moderate associations with whole carcass and section CT lean and fat %, with R<sup>2</sup> values generally less than half those of the AutoFom III. The HGP demonstrated weakest associations with CT lean and fat % using either lean % or P2 outputs, which is likely related to data being collected from only the P2 measurement site. This is the first experiment to compare the strength of associations between multiple pork abattoir measurement devices and CT lean and fat % in Australia. P2 is the current industry standard for the assessment of lean yield in pork, however demonstrates weaker associations with carcass CT composition than devices capable of capturing multiple measures across the carcass like AutoFom III and PorkScan Plus.</p></div>","PeriodicalId":389,"journal":{"name":"Meat Science","volume":"217 ","pages":"Article 109612"},"PeriodicalIF":7.1000,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S030917402400189X/pdfft?md5=8fc47337aac1a3ccf8a0a066fbc4defa&pid=1-s2.0-S030917402400189X-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Meat Science","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S030917402400189X","RegionNum":1,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
引用次数: 0
Abstract
Pork carcasses were obtained from three abattoirs in Australia (n = 345) where technologies enabled collection of post slaughter measures of P2 fat depth (mm) (Hennessy Grading Probe (HGP), AutoFom III, PorkScan Lite) and estimates of carcass lean % (HGP, AutoFom III, PorkScan Plus). Computed tomography (CT) was used to scan carcasses and determine lean and fat %, with the strength of associations with abattoir measurement devices determined. The AutoFom III lean % demonstrated the strongest associations with whole carcass CT lean % (R2 0.63, RMSE 1.73) and fat % (R2 0.68, RMSE 1.80) and with section (fore, loin, belly and hind) CT composition. The association of P2 from AutoFom III was lower in comparison, however remained superior to other commercial devices (PorkScan Lite and HGP). Porkscan Plus lean % demonstrated moderate associations with whole carcass and section CT lean and fat %, with R2 values generally less than half those of the AutoFom III. The HGP demonstrated weakest associations with CT lean and fat % using either lean % or P2 outputs, which is likely related to data being collected from only the P2 measurement site. This is the first experiment to compare the strength of associations between multiple pork abattoir measurement devices and CT lean and fat % in Australia. P2 is the current industry standard for the assessment of lean yield in pork, however demonstrates weaker associations with carcass CT composition than devices capable of capturing multiple measures across the carcass like AutoFom III and PorkScan Plus.
期刊介绍:
The aim of Meat Science is to serve as a suitable platform for the dissemination of interdisciplinary and international knowledge on all factors influencing the properties of meat. While the journal primarily focuses on the flesh of mammals, contributions related to poultry will be considered if they enhance the overall understanding of the relationship between muscle nature and meat quality post mortem. Additionally, papers on large birds (e.g., emus, ostriches) as well as wild-captured mammals and crocodiles will be welcomed.