A high rate and high timing photoelectric detector prototype with RPC structure

Yiding Zhao, D. Hu, M. Shao, Y. Zhou, S. Lv, Xiangqi Tian, Anqi Wang, Xueshen Lin, Hao Pang, Y. Suna
{"title":"A high rate and high timing photoelectric detector prototype with RPC structure","authors":"Yiding Zhao, D. Hu, M. Shao, Y. Zhou, S. Lv, Xiangqi Tian, Anqi Wang, Xueshen Lin, Hao Pang, Y. Suna","doi":"arxiv-2407.19720","DOIUrl":null,"url":null,"abstract":"To meet the need for a high counting rate and high time resolution in future\nhigh-energy physics experiments, a prototype of a gas photodetector with an RPC\nstructure was developed. Garfield++ simulated the detector's performance, and\nthe single photoelectron performance of different mixed gases was tested with\nan ultraviolet laser. The detector uses a low resistivity ($\\sim1.4\\cdot\n10^{10} \\Omega\\cdot cm$) float glass so that its rate capability is\nsignificantly higher than that of ordinary float glass($10^{12}\\sim10^{14}\n\\Omega\\cdot cm$), the laser test results show that in MRPC\ngas($R134a/iC_{4}H_{10}/SF_{6}(85/10/5)$), the single photoelectron time\nresolution is best to reach 20.3 ps at a gas gain of $7\\cdot 10^{6}$.\nIncreasing the proportion of $iC_{4}H_{10}$ can effectively reduce the\nprobability of photon feedback, without changing the time resolution and\nmaximum gain. In addition to being applied to high-precision time measurement\nscenarios (eg:T0, TOF), the detector can also quantitatively test the single\nphotoelectron performance of different gases and will be used to find\neco-friendly MRPC gases.","PeriodicalId":501374,"journal":{"name":"arXiv - PHYS - Instrumentation and Detectors","volume":"68 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Instrumentation and Detectors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2407.19720","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the single photoelectron performance of different mixed gases was tested with an ultraviolet laser. The detector uses a low resistivity ($\sim1.4\cdot 10^{10} \Omega\cdot cm$) float glass so that its rate capability is significantly higher than that of ordinary float glass($10^{12}\sim10^{14} \Omega\cdot cm$), the laser test results show that in MRPC gas($R134a/iC_{4}H_{10}/SF_{6}(85/10/5)$), the single photoelectron time resolution is best to reach 20.3 ps at a gas gain of $7\cdot 10^{6}$. Increasing the proportion of $iC_{4}H_{10}$ can effectively reduce the probability of photon feedback, without changing the time resolution and maximum gain. In addition to being applied to high-precision time measurement scenarios (eg:T0, TOF), the detector can also quantitatively test the single photoelectron performance of different gases and will be used to find eco-friendly MRPC gases.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用 RPC 结构的高速率、高定时光电探测器原型
为了满足未来高能物理实验对高计数率和高时间分辨率的需求,我们开发了一种具有 RPC 结构的气体光电探测器原型。Garfield++ 模拟了探测器的性能,并用紫外激光测试了不同混合气体的单光电子性能。探测器使用低电阻率($\sim1.激光测试结果表明,在 MRPC 气体($R134a/iC_{4}H_{10}/SF_{6}(85/10/5)$)中,单光电子时间分辨率最好能达到 20.增加 iC_{4}H_{10}$ 的比例可以有效降低光子反馈的概率,而不会改变时间分辨率和最大增益。除了应用于高精度时间测量场景(如:T0、TOF)之外,该探测器还可以定量测试不同气体的单光电子性能,并将用于寻找对环境友好的 MRPC 气体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Impedance Matching Networks for Scanning Microwave Microscopy Ultraviolet cross-luminescence in ternary chlorides of alkali and alkaline-earth metals Performance Evaluation of an RFSoC Operating in a 1.25 Tesla Magnetic Field Numerical Studies of Straw Tube Detectors Advanced Halide Scintillators: From the Bulk to Nano
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1