Cameron W Leafloor, Andrew D McRae, Eric Mercier, Justin W Yan, Paul Huang, Muhammad Mukarram, Brian H Rowe, Aline C Ishimwe, Mona Hegdekar, Marco L A Sivilotti, Monica Taljaard, Marie-Joe Nemnom, Venkatesh Thiruganasambandamoorthy
{"title":"Utility of serial troponin testing for emergency department patients with syncope.","authors":"Cameron W Leafloor, Andrew D McRae, Eric Mercier, Justin W Yan, Paul Huang, Muhammad Mukarram, Brian H Rowe, Aline C Ishimwe, Mona Hegdekar, Marco L A Sivilotti, Monica Taljaard, Marie-Joe Nemnom, Venkatesh Thiruganasambandamoorthy","doi":"10.1007/s43678-024-00740-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>For emergency department (ED) patients with syncope, cardiac troponin can identify acute coronary syndrome (ACS) and prognosticate for 30-day serious adverse events. However, it is unclear if serial testing improves diagnostic yield and prognostication.</p><p><strong>Methods: </strong>This was a secondary analysis of data from two prospective studies conducted to develop the Canadian Syncope Risk Score. Adults (age ≥ 16 years) with syncope were enrolled, and patient characteristics, vital signs, physician diagnostic impression, electrocardiogram and troponin results, and adjudicated 30-day serious adverse event were collected. The primary outcome was the detection of a serious adverse event within 30 days of ED disposition. The secondary outcome was comparison of ED length of stay among patients with single versus serial troponin measurements.</p><p><strong>Results: </strong>4996 patients [mean age 64.5 (SD 18.8) years, 52.2% male] were included: 4397 (89.8%) with single troponin [232 (5.3%) with serious adverse event in the ED and 203 (4.6%) after ED disposition]; 499 (10.2%) patients with > 1 troponin measurement [39 (7.8%) with serious adverse event in ED and 60 (12.0%) after ED disposition]. Among those with serial measurements, 10 patients (2.0%) had a rise from below to above the 99th percentile threshold, of whom 4 patients (0.8%) suffered serious adverse event: two with arrhythmias diagnosed on electrocardiogram, one with ACS and one suffered respiratory failure. Nine patients (1.8%) had Canadian Syncope Risk Score risk reclassification based on serial measurement, and none suffered 30-day serious adverse event. Median ED length of stay was significantly longer for patients with serial testing (5.6 vs. 3.8 h, p < 0.001).</p><p><strong>Conclusions: </strong>The initial troponin measurement was sufficient for serious adverse event detection and in-ED risk stratification. Serial troponin testing does not improve the diagnostic yield or prognostication and should be reserved for patients with ongoing symptoms or electrocardiogram findings suggestive of cardiac ischemia.</p>","PeriodicalId":93937,"journal":{"name":"CJEM","volume":" ","pages":"535-542"},"PeriodicalIF":2.4000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CJEM","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s43678-024-00740-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/2 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: For emergency department (ED) patients with syncope, cardiac troponin can identify acute coronary syndrome (ACS) and prognosticate for 30-day serious adverse events. However, it is unclear if serial testing improves diagnostic yield and prognostication.
Methods: This was a secondary analysis of data from two prospective studies conducted to develop the Canadian Syncope Risk Score. Adults (age ≥ 16 years) with syncope were enrolled, and patient characteristics, vital signs, physician diagnostic impression, electrocardiogram and troponin results, and adjudicated 30-day serious adverse event were collected. The primary outcome was the detection of a serious adverse event within 30 days of ED disposition. The secondary outcome was comparison of ED length of stay among patients with single versus serial troponin measurements.
Results: 4996 patients [mean age 64.5 (SD 18.8) years, 52.2% male] were included: 4397 (89.8%) with single troponin [232 (5.3%) with serious adverse event in the ED and 203 (4.6%) after ED disposition]; 499 (10.2%) patients with > 1 troponin measurement [39 (7.8%) with serious adverse event in ED and 60 (12.0%) after ED disposition]. Among those with serial measurements, 10 patients (2.0%) had a rise from below to above the 99th percentile threshold, of whom 4 patients (0.8%) suffered serious adverse event: two with arrhythmias diagnosed on electrocardiogram, one with ACS and one suffered respiratory failure. Nine patients (1.8%) had Canadian Syncope Risk Score risk reclassification based on serial measurement, and none suffered 30-day serious adverse event. Median ED length of stay was significantly longer for patients with serial testing (5.6 vs. 3.8 h, p < 0.001).
Conclusions: The initial troponin measurement was sufficient for serious adverse event detection and in-ED risk stratification. Serial troponin testing does not improve the diagnostic yield or prognostication and should be reserved for patients with ongoing symptoms or electrocardiogram findings suggestive of cardiac ischemia.