The Sydney system for lymph node FNA biopsy cytopathology: A detailed analysis of recent publications and meta-analysis and a proposal for the components of an ideal prospective study of a cytopathology reporting system
Sharron Liang MB, BS, FRCPA, Immacolata Cozzolino MD, Pio Zeppa MD, Andrew S. Field MB, BS(Hons), FRCPA, FIAC
{"title":"The Sydney system for lymph node FNA biopsy cytopathology: A detailed analysis of recent publications and meta-analysis and a proposal for the components of an ideal prospective study of a cytopathology reporting system","authors":"Sharron Liang MB, BS, FRCPA, Immacolata Cozzolino MD, Pio Zeppa MD, Andrew S. Field MB, BS(Hons), FRCPA, FIAC","doi":"10.1002/cncy.22890","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>The Sydney system for fine-needle aspiration biopsy of lymph nodes has five categories, stressing the role of correlation of cytopathology with clinical, ultrasound, and ancillary findings to achieve diagnosis. The five categories constitute a hierarchical system with increasing risk of malignancy from benign to atypical, suspicious, and malignant categories, which informs recommendations for further workup to achieve a final diagnosis as possible. This article analyzes 10 publications using the Sydney system and a meta-analysis of nine of these studies. The primary goal of the analysis is to ascertain the causes of the large ranges in risk of malignancy for the “atypical” and “inadequate” compared to “benign,” “suspicious,” and “malignant” categories, which were comparable to well-established reporting systems. Research protocols are proposed to improve future studies.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>PubMed literature search from January 2021 to December 2023 identified studies evaluating performance of the Sydney system.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Ten studies showed heterogeneity with clinical setting, study design, ultrasound use and rapid on-site evaluation, operator, cutoff points for “positive” cases, with inherent partial verification biases, resulting in a wide range of risk of malignancy, specificity, and sensitivity values.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Analysis shows the large range is due to heterogeneity of the studies, which suffer from biases and variable statistical analysis that are ultimately included in any meta-analysis, detracting from the usefulness of the risk of malignancy derived by the meta-analysis. Components for ideal analyses of reporting systems are presented.</p>\n </section>\n </div>","PeriodicalId":9410,"journal":{"name":"Cancer Cytopathology","volume":"132 12","pages":"745-756"},"PeriodicalIF":2.6000,"publicationDate":"2024-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cncy.22890","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancer Cytopathology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cncy.22890","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The Sydney system for fine-needle aspiration biopsy of lymph nodes has five categories, stressing the role of correlation of cytopathology with clinical, ultrasound, and ancillary findings to achieve diagnosis. The five categories constitute a hierarchical system with increasing risk of malignancy from benign to atypical, suspicious, and malignant categories, which informs recommendations for further workup to achieve a final diagnosis as possible. This article analyzes 10 publications using the Sydney system and a meta-analysis of nine of these studies. The primary goal of the analysis is to ascertain the causes of the large ranges in risk of malignancy for the “atypical” and “inadequate” compared to “benign,” “suspicious,” and “malignant” categories, which were comparable to well-established reporting systems. Research protocols are proposed to improve future studies.
Methods
PubMed literature search from January 2021 to December 2023 identified studies evaluating performance of the Sydney system.
Results
Ten studies showed heterogeneity with clinical setting, study design, ultrasound use and rapid on-site evaluation, operator, cutoff points for “positive” cases, with inherent partial verification biases, resulting in a wide range of risk of malignancy, specificity, and sensitivity values.
Conclusion
Analysis shows the large range is due to heterogeneity of the studies, which suffer from biases and variable statistical analysis that are ultimately included in any meta-analysis, detracting from the usefulness of the risk of malignancy derived by the meta-analysis. Components for ideal analyses of reporting systems are presented.
期刊介绍:
Cancer Cytopathology provides a unique forum for interaction and dissemination of original research and educational information relevant to the practice of cytopathology and its related oncologic disciplines. The journal strives to have a positive effect on cancer prevention, early detection, diagnosis, and cure by the publication of high-quality content. The mission of Cancer Cytopathology is to present and inform readers of new applications, technological advances, cutting-edge research, novel applications of molecular techniques, and relevant review articles related to cytopathology.