The utility of temporal trends of blood biomarkers as predictors for bloodstream infections in left ventricular assist device recipients.

IF 2.2 3区 医学 Q3 ENGINEERING, BIOMEDICAL Artificial organs Pub Date : 2024-08-06 DOI:10.1111/aor.14839
Kamen Dimitrov, Alexandra Kaider, Christoph Gross, Selma Rizvanovic, Flogin Pepa, Marcus Granegger, Johanna Schlein, Philipp Angleitner, Dominik Wiedemann, Julia Riebandt, Thomas Schlöglhofer, Günther Laufer, Daniel Zimpfer
{"title":"The utility of temporal trends of blood biomarkers as predictors for bloodstream infections in left ventricular assist device recipients.","authors":"Kamen Dimitrov, Alexandra Kaider, Christoph Gross, Selma Rizvanovic, Flogin Pepa, Marcus Granegger, Johanna Schlein, Philipp Angleitner, Dominik Wiedemann, Julia Riebandt, Thomas Schlöglhofer, Günther Laufer, Daniel Zimpfer","doi":"10.1111/aor.14839","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Temporal trends of routinely obtained parameters may provide valuable information for predicting BSIs, but this association has not yet been established in LVAD patients.</p><p><strong>Methods: </strong>This retrospective analysis included data from 347 consecutive recipients of three rotary LVAD types. Study endpoints included the incidence of BSI, the association of temporal trends of routinely obtained blood biomarkers with the development of BSIs, the incidence of BSIs, and survival on LVAD support.</p><p><strong>Results: </strong>During follow-up, 47.8% (n = 166) of the patients developed BSI. In multivariate analyses, the development of BSI was a significant predictor of mortality (HR 5.78, 95% CI 4.08-8.19, p < 0.0001). In univariate analyses, after adjusting for potential confounders, albumin (SHR 0.94, 95% CI 0.91-0.97, p < 0.00010), creatinine (SHR 1.49, 95% CI 1.03-2.15, p = 0.033), and C-reactive protein (SHR 1.19, 95% CI 1.08-1.32, p = 0.0007) significantly predicted the development of BSIs during LVAD support. Notably, the strength of the association of parameter changes with the prediction of BSIs demonstrated a time-dependent correlation in the cases of albumin (p = 0.045) and creatinine (p = 0.003).</p><p><strong>Conclusion: </strong>Bloodstream infections are highly prevalent among LVAD recipients and are independent predictors of mortality. Temporal biomarker trends significantly predict the development of BSIs. These findings suggest opportunities for interventions aiming to reduce the incidence of BSIs.</p>","PeriodicalId":8450,"journal":{"name":"Artificial organs","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/aor.14839","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Temporal trends of routinely obtained parameters may provide valuable information for predicting BSIs, but this association has not yet been established in LVAD patients.

Methods: This retrospective analysis included data from 347 consecutive recipients of three rotary LVAD types. Study endpoints included the incidence of BSI, the association of temporal trends of routinely obtained blood biomarkers with the development of BSIs, the incidence of BSIs, and survival on LVAD support.

Results: During follow-up, 47.8% (n = 166) of the patients developed BSI. In multivariate analyses, the development of BSI was a significant predictor of mortality (HR 5.78, 95% CI 4.08-8.19, p < 0.0001). In univariate analyses, after adjusting for potential confounders, albumin (SHR 0.94, 95% CI 0.91-0.97, p < 0.00010), creatinine (SHR 1.49, 95% CI 1.03-2.15, p = 0.033), and C-reactive protein (SHR 1.19, 95% CI 1.08-1.32, p = 0.0007) significantly predicted the development of BSIs during LVAD support. Notably, the strength of the association of parameter changes with the prediction of BSIs demonstrated a time-dependent correlation in the cases of albumin (p = 0.045) and creatinine (p = 0.003).

Conclusion: Bloodstream infections are highly prevalent among LVAD recipients and are independent predictors of mortality. Temporal biomarker trends significantly predict the development of BSIs. These findings suggest opportunities for interventions aiming to reduce the incidence of BSIs.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血液生物标志物的时间趋势作为左心室辅助装置受术者血流感染预测指标的实用性。
背景:常规参数的时间趋势可为预测 BSI 提供有价值的信息,但这种关联尚未在 LVAD 患者中确立:这项回顾性分析包括三种旋转式 LVAD 的 347 名连续接受者的数据。研究终点包括 BSI 的发生率、常规获得的血液生物标志物的时间趋势与 BSI 发生的关联、BSI 的发生率以及 LVAD 支持的存活率:结果:在随访期间,47.8%(n = 166)的患者发生了 BSI。在多变量分析中,BSI的发生是死亡率的重要预测因素(HR 5.78,95% CI 4.08-8.19,P 结论:血流感染在 LVAD 患者中非常普遍:血流感染在 LVAD 受者中非常普遍,是死亡率的独立预测因素。生物标志物的时间趋势可显著预测 BSI 的发生。这些发现为旨在降低 BSI 发生率的干预措施提供了机会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Artificial organs
Artificial organs 工程技术-工程:生物医学
CiteScore
4.30
自引率
12.50%
发文量
303
审稿时长
4-8 weeks
期刊介绍: Artificial Organs is the official peer reviewed journal of The International Federation for Artificial Organs (Members of the Federation are: The American Society for Artificial Internal Organs, The European Society for Artificial Organs, and The Japanese Society for Artificial Organs), The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, The International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation. Artificial Organs publishes original research articles dealing with developments in artificial organs applications and treatment modalities and their clinical applications worldwide. Membership in the Societies listed above is not a prerequisite for publication. Articles are published without charge to the author except for color figures and excess page charges as noted.
期刊最新文献
Improving the hemocompatibility of centrifugal mechanical circulatory support devices at low flow rates. Early left ventricular unloading during extracorporeal membrane oxygenation in cardiogenic shock: A systematic review and meta-analysis. Safety and efficacy of surgical revascularization with percutaneous ventricular assist device for acute myocardial infarction complicated by cardiogenic shock: Japanese national registry study. Evaluation of extra-corporeal membrane oxygenator cannulae in pulsatile and non-pulsatile pediatric mock circuits. Stimulation of the withdrawal reflex in gait training after stroke: A systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1