Comparison of CT and MRI in diagnosing occult hip fracture: a systematic review and meta-analysis.

IF 1.7 4区 医学 Q3 MEDICINE, RESEARCH & EXPERIMENTAL American journal of translational research Pub Date : 2024-07-15 eCollection Date: 2024-01-01 DOI:10.62347/NUBB1946
Hongxue Qu, Lei Bian
{"title":"Comparison of CT and MRI in diagnosing occult hip fracture: a systematic review and meta-analysis.","authors":"Hongxue Qu, Lei Bian","doi":"10.62347/NUBB1946","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the diagnostic accuracy of computed tomography (CT) scans and magnetic resonance imaging (MRI) in detecting occult hip fractures.</p><p><strong>Methods: </strong>We conducted a systematic literature review and identified 12 articles involving 1,819 participants for inclusion. Data extraction and quality assessment were performed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Publication bias was assessed with the Deek funnel plot asymmetry test. We conducted a meta-analysis using a random-effects model to derive pooled estimates of sensitivity, specificity, positive and negative likelihood ratios, and the diagnostic odds ratio, along with their 95% confidence intervals. A summary receiver operating characteristic curve was generated to illustrate the overall diagnostic accuracy.</p><p><strong>Results: </strong>The methodological quality of the included studies was high, with minimal concerns about the applicability of the tests in clinical settings. Both CT and MRI showed good diagnostic efficacy for occult hip fractures. However, MRI consistently outperformed CT, exhibiting significantly higher sensitivity, specificity, and likelihood ratios, thereby providing superior accuracy in confirming or excluding occult fractures. Meta-regression analysis revealed that sequence parameters and sample size significantly influenced the differences in sensitivity and specificity between CT and MRI.</p><p><strong>Conclusion: </strong>Both CT and MRI are effective modalities for detecting occult hip fractures, with MRI demonstrating greater diagnostic accuracy. This meta-analysis supports the use of MRI when higher sensitivity and specificity are required in clinical practice.</p>","PeriodicalId":7731,"journal":{"name":"American journal of translational research","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11301482/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of translational research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.62347/NUBB1946","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare the diagnostic accuracy of computed tomography (CT) scans and magnetic resonance imaging (MRI) in detecting occult hip fractures.

Methods: We conducted a systematic literature review and identified 12 articles involving 1,819 participants for inclusion. Data extraction and quality assessment were performed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Publication bias was assessed with the Deek funnel plot asymmetry test. We conducted a meta-analysis using a random-effects model to derive pooled estimates of sensitivity, specificity, positive and negative likelihood ratios, and the diagnostic odds ratio, along with their 95% confidence intervals. A summary receiver operating characteristic curve was generated to illustrate the overall diagnostic accuracy.

Results: The methodological quality of the included studies was high, with minimal concerns about the applicability of the tests in clinical settings. Both CT and MRI showed good diagnostic efficacy for occult hip fractures. However, MRI consistently outperformed CT, exhibiting significantly higher sensitivity, specificity, and likelihood ratios, thereby providing superior accuracy in confirming or excluding occult fractures. Meta-regression analysis revealed that sequence parameters and sample size significantly influenced the differences in sensitivity and specificity between CT and MRI.

Conclusion: Both CT and MRI are effective modalities for detecting occult hip fractures, with MRI demonstrating greater diagnostic accuracy. This meta-analysis supports the use of MRI when higher sensitivity and specificity are required in clinical practice.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CT 和 MRI 在诊断隐性髋部骨折方面的比较:系统回顾和荟萃分析。
目的比较计算机断层扫描(CT)和磁共振成像(MRI)在检测隐匿性髋部骨折方面的诊断准确性:我们进行了系统性文献回顾,并确定了 12 篇涉及 1819 名参与者的文章作为研究对象。数据提取和质量评估采用诊断准确性研究质量评估-2工具进行。文献发表偏倚采用 Deek 漏斗图不对称检验进行评估。我们使用随机效应模型进行了荟萃分析,得出了灵敏度、特异性、正似然比、负似然比和诊断几率的集合估计值及其 95% 置信区间。研究还生成了接收者操作特征曲线,以说明总体诊断准确性:结果:纳入研究的方法学质量较高,对检测在临床环境中的适用性的担忧很小。CT 和 MRI 对隐匿性髋部骨折均有良好的诊断效果。不过,核磁共振成像的效果始终优于 CT,其敏感性、特异性和似然比都明显高于 CT,因此在确诊或排除隐匿性骨折方面具有更高的准确性。元回归分析表明,序列参数和样本大小对 CT 和 MRI 的敏感性和特异性差异有显著影响:结论:CT 和 MRI 都是检测隐匿性髋部骨折的有效方法,其中 MRI 的诊断准确性更高。这项荟萃分析支持在临床实践中需要更高灵敏度和特异性时使用核磁共振成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
American journal of translational research
American journal of translational research ONCOLOGY-MEDICINE, RESEARCH & EXPERIMENTAL
自引率
0.00%
发文量
552
期刊介绍: Information not localized
期刊最新文献
Comparison of the effectiveness of neoadjuvant chemotherapy and adjuvant chemotherapy for improving prognosis in triple-negative breast cancer patients. Comparison of the efficacy of phloroglucinol versus ritodrine hydrochloride in preventing miscarriage and adverse reactions. Comparison of the therapeutic efficacy of hip arthroplasty and proximal femoral nail antirotation internal fixation for unstable intertrochanteric femur fractures. A comparative study of the efficacy and safety of PD-1/L1 inhibitor and platinum-containing dual-agent chemotherapy in patients with advanced non-small cell lung cancer resistant to EGFR-TKIs. A dual analysis of bougie and stylet development trend and impact of Chinese regulations on medical devices innovation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1