Automated quantification of periodic discharges in human electroencephalogram.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Biomedical Physics & Engineering Express Pub Date : 2024-09-20 DOI:10.1088/2057-1976/ad6c53
Christopher M McGraw, Samvrit Rao, Shashank Manjunath, Jin Jing, M Brandon Westover
{"title":"Automated quantification of periodic discharges in human electroencephalogram.","authors":"Christopher M McGraw, Samvrit Rao, Shashank Manjunath, Jin Jing, M Brandon Westover","doi":"10.1088/2057-1976/ad6c53","DOIUrl":null,"url":null,"abstract":"<p><p>Periodic discharges (PDs) are pathologic patterns of epileptiform discharges repeating at regular intervals, commonly detected in the human electroencephalogram (EEG) signals in patients who are critically ill. The frequency and spatial extent of PDs are associated with the tendency of PDs to cause brain injury, existing automated algorithms do not quantify the frequency and spatial extent of PDs. The present study presents an algorithm for quantifying frequency and spatial extent of PDs. The algorithm quantifies the evolution of these parameters within a short (10-14 second) window, with a focus on lateralized and generalized periodic discharges. We test our algorithm on 300 'easy', 300 'medium', and 240 'hard' examples (840 total epochs) of periodic discharges as quantified by interrater consensus from human experts when analyzing the given EEG epochs. We observe 95.0% agreement with a 95% confidence interval (CI) of [94.9%, 95.1%] between algorithm outputs with reviewer clincal judgement for easy examples, 92.0% agreement (95% CI [91.9%, 92.2%]) for medium examples, and 90.4% agreement (95% CI [90.3%, 90.6%]) for hard examples. The algorithm is also computationally efficient and is able to run in 0.385 ± 0.038 seconds for a single epoch using our provided implementation of the algorithm. The results demonstrate the algorithm's effectiveness in quantifying these discharges and provide a standardized and efficient approach for PD quantification as compared to existing manual approaches.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11580140/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/ad6c53","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Periodic discharges (PDs) are pathologic patterns of epileptiform discharges repeating at regular intervals, commonly detected in the human electroencephalogram (EEG) signals in patients who are critically ill. The frequency and spatial extent of PDs are associated with the tendency of PDs to cause brain injury, existing automated algorithms do not quantify the frequency and spatial extent of PDs. The present study presents an algorithm for quantifying frequency and spatial extent of PDs. The algorithm quantifies the evolution of these parameters within a short (10-14 second) window, with a focus on lateralized and generalized periodic discharges. We test our algorithm on 300 'easy', 300 'medium', and 240 'hard' examples (840 total epochs) of periodic discharges as quantified by interrater consensus from human experts when analyzing the given EEG epochs. We observe 95.0% agreement with a 95% confidence interval (CI) of [94.9%, 95.1%] between algorithm outputs with reviewer clincal judgement for easy examples, 92.0% agreement (95% CI [91.9%, 92.2%]) for medium examples, and 90.4% agreement (95% CI [90.3%, 90.6%]) for hard examples. The algorithm is also computationally efficient and is able to run in 0.385 ± 0.038 seconds for a single epoch using our provided implementation of the algorithm. The results demonstrate the algorithm's effectiveness in quantifying these discharges and provide a standardized and efficient approach for PD quantification as compared to existing manual approaches.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自动量化人体脑电图中的周期性放电
周期性放电(PDs)是癫痫样放电每隔一定时间重复出现的病理模式,通常在危重病人的脑电图(EEG)信号中检测到。痫性放电的频率和空间范围与痫性放电导致脑损伤的倾向有关,现有的自动算法无法量化痫性放电的频率和空间范围。本研究提出了一种用于量化脑干畸形频率和空间范围的算法 。该算法可量化这些参数在短时间(10-14 秒)窗口内的变化,重点关注侧向和泛化周期性放电。我们在300个 "简单"、300个 "中等 "和240个 "困难 "的周期性放电实例(总计840个历时)上测试了我们的算法。我们观察到,对于简单的例子,算法输出与审查员的临床判断之间的一致性为95.0%$ ,95%置信区间(CI)为$[94.9%/%, 95.1%/%]$,而对于复杂的例子,算法输出与审查员的临床判断之间的一致性为92.0%$ 。0%$ 一致(95% CI $[91.9\%,92.2\%]$),90.4%$ 一致(95% CI $[90.3\%,90.6\%]$)。该算法的计算效率也很高,使用我们提供的算法实现,单个epoch的运行时间为0.385 \pm 0.038$秒 。结果证明了该算法在量化这些放电方面的有效性,与现有的人工方法相比,该算法提供了一种标准化、高效的PD 量化方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
期刊最新文献
Validation of the SIMIND simulation code using the myocardial phantom HL. Optimized scintillation imaging in low dose rate and bright room light conditions. Computer-aided diagnosis of early-stage Retinopathy of Prematurity in neonatal fundus images using artificial intelligence. Green hydrothermal synthesis of gallic acid carbon dots: characterization and cytotoxic effects on colorectal cancer cell line. Nanodosimetric investigation of the track structure of therapeutic carbon ion radiation part2: detailed simulation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1