A. M. Bucher, Adrian Koppold, Mattias Kettner, Sarah Kölzer, Julia Dietz, Eric Frodl, Alexey Surov, Daniel Pinto dos Santos, Thomas J. Vogl, M. A. Verhoff, M. Beeres, Constantin Lux, Sara Heinbuch
{"title":"Enhancing Forensic Diagnostics: Structured Reporting of Post-Mortem CT versus Autopsy for Laryngohyoid Complex Fractures in Strangulation","authors":"A. M. Bucher, Adrian Koppold, Mattias Kettner, Sarah Kölzer, Julia Dietz, Eric Frodl, Alexey Surov, Daniel Pinto dos Santos, Thomas J. Vogl, M. A. Verhoff, M. Beeres, Constantin Lux, Sara Heinbuch","doi":"10.3390/bioengineering11080807","DOIUrl":null,"url":null,"abstract":"Background: The purpose of this study was to establish a standardized structured workflow to compare findings from high-resolution, optimized reconstructions from post-mortem computed tomography (pmCT) with autopsy results in the detection of fractures of the laryngohyoid complex in strangulation victims. Method: Forty-two strangulation cases were selected, and pmCT scans of the laryngohyoid complex were obtained. Both pmCT scans and autopsy reports were analyzed using a structured template and compared using Cohen’s kappa coefficient (κ) and the McNemar test. The study also compared the prevalence of ossa sesamoidea and non-fusion of the major and minor horns of the hyoid bone between both diagnostic methods. Results: The detection of fractures showed a very good correlation between autopsy and pmCT results (κ = 0.905), with the McNemar test showing no statistically significant difference between the two methods. PmCT identified 28 sesamoid bones, 45 non-fusions of the major horns, and 47 non-fusions of the minor horns of the hyoid bone, compared to four, six, and zero, respectively, identified by autopsy (p < 0.0001). Conclusions: Autopsy and pmCT findings correlate well and can be used in a complementary manner. PmCT is superior to autopsy in identifying dislocations and detecting anatomical variations in the laryngohyoid complex, which can lead to misinterpretations during autopsy. Therefore, we do not advocate replacing autopsy with pmCT but propose using a structured workflow, including our standardized reporting template, for evaluating lesions in the laryngohyoid complex.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"20 5","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11080807","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The purpose of this study was to establish a standardized structured workflow to compare findings from high-resolution, optimized reconstructions from post-mortem computed tomography (pmCT) with autopsy results in the detection of fractures of the laryngohyoid complex in strangulation victims. Method: Forty-two strangulation cases were selected, and pmCT scans of the laryngohyoid complex were obtained. Both pmCT scans and autopsy reports were analyzed using a structured template and compared using Cohen’s kappa coefficient (κ) and the McNemar test. The study also compared the prevalence of ossa sesamoidea and non-fusion of the major and minor horns of the hyoid bone between both diagnostic methods. Results: The detection of fractures showed a very good correlation between autopsy and pmCT results (κ = 0.905), with the McNemar test showing no statistically significant difference between the two methods. PmCT identified 28 sesamoid bones, 45 non-fusions of the major horns, and 47 non-fusions of the minor horns of the hyoid bone, compared to four, six, and zero, respectively, identified by autopsy (p < 0.0001). Conclusions: Autopsy and pmCT findings correlate well and can be used in a complementary manner. PmCT is superior to autopsy in identifying dislocations and detecting anatomical variations in the laryngohyoid complex, which can lead to misinterpretations during autopsy. Therefore, we do not advocate replacing autopsy with pmCT but propose using a structured workflow, including our standardized reporting template, for evaluating lesions in the laryngohyoid complex.
期刊介绍:
ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric.
Indexed/Abstracted:
Web of Science SCIE
Scopus
CAS
INSPEC
Portico