Experimental and Numerical Study on Air Cooling System Dedicated to Photovoltaic Panels

IF 4.7 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-08-09 DOI:10.3390/en17163949
Maksymilian Homa, K. Sornek, W. Goryl
{"title":"Experimental and Numerical Study on Air Cooling System Dedicated to Photovoltaic Panels","authors":"Maksymilian Homa, K. Sornek, W. Goryl","doi":"10.3390/en17163949","DOIUrl":null,"url":null,"abstract":"The efficiency of solar systems, in particular photovoltaic panels, is typically low. Various environmental parameters affect solar panels, including sunlight, the ambient and module surface temperatures, the wind speed, humidity, shading, dust, the installation height, etc. Among others, the key players are indeed solar irradiance and temperature. The higher the temperature is, the higher the short-circuit current is, and the lower the open-circuit voltage is. The negative effect of lowering the open-circuit voltage is dominant, consequently lowering the power of the photovoltaic panels. Passive or active cooling systems can be provided to avoid the negative effect of temperature. This paper presents a prototype of an active cooling system dedicated to photovoltaics. The prototype of such a system was developed at the AGH University of Kraków and tested under laboratory conditions. The proposed system is equipped with air fans mounted on a plate connected to the rear part of a 70 Wp photovoltaic panel. Different configurations of the system were tested, including different numbers of fans and different locations of the fans. The artificial light source generated a irradiation value of 770 W/m2. This value was present for every variant tested in the experiment. As observed, the maximum power generated in the photovoltaic panel under laboratory conditions was approx. 47.31 W. Due to the temperature increase, this power was reduced to 40.09 W (when the temperature of the uncooled panel surface reached 60 °C). On the other hand, the power generated in the photovoltaic panel equipped with the developed cooling system was approx. 44.37 W in the same conditions (i.e., it was higher by 10.7% compared to that of the uncooled one). A mathematical model was developed based on the results obtained, and simulations were carried out using the ANSYS Workbench software. After the validation procedure, several configurations of the air cooling system were developed and analyzed. The most prominent case was chosen for additional parametrical analysis. The optimum fan orientation was recognized: a vertical tilt of 7° and a horizontal tilt of 10°. For the tested module, this modification resulted in a cost-effective system (a net power increase of ~3.1%).","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"30 51","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/en17163949","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The efficiency of solar systems, in particular photovoltaic panels, is typically low. Various environmental parameters affect solar panels, including sunlight, the ambient and module surface temperatures, the wind speed, humidity, shading, dust, the installation height, etc. Among others, the key players are indeed solar irradiance and temperature. The higher the temperature is, the higher the short-circuit current is, and the lower the open-circuit voltage is. The negative effect of lowering the open-circuit voltage is dominant, consequently lowering the power of the photovoltaic panels. Passive or active cooling systems can be provided to avoid the negative effect of temperature. This paper presents a prototype of an active cooling system dedicated to photovoltaics. The prototype of such a system was developed at the AGH University of Kraków and tested under laboratory conditions. The proposed system is equipped with air fans mounted on a plate connected to the rear part of a 70 Wp photovoltaic panel. Different configurations of the system were tested, including different numbers of fans and different locations of the fans. The artificial light source generated a irradiation value of 770 W/m2. This value was present for every variant tested in the experiment. As observed, the maximum power generated in the photovoltaic panel under laboratory conditions was approx. 47.31 W. Due to the temperature increase, this power was reduced to 40.09 W (when the temperature of the uncooled panel surface reached 60 °C). On the other hand, the power generated in the photovoltaic panel equipped with the developed cooling system was approx. 44.37 W in the same conditions (i.e., it was higher by 10.7% compared to that of the uncooled one). A mathematical model was developed based on the results obtained, and simulations were carried out using the ANSYS Workbench software. After the validation procedure, several configurations of the air cooling system were developed and analyzed. The most prominent case was chosen for additional parametrical analysis. The optimum fan orientation was recognized: a vertical tilt of 7° and a horizontal tilt of 10°. For the tested module, this modification resulted in a cost-effective system (a net power increase of ~3.1%).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
光伏电池板专用空气冷却系统的实验和数值研究
太阳能系统,尤其是光伏电池板的效率通常很低。影响太阳能电池板的环境参数多种多样,包括阳光、环境温度和组件表面温度、风速、湿度、遮阳、灰尘、安装高度等。其中,太阳辐照度和温度是影响太阳能电池板的关键因素。温度越高,短路电流越大,开路电压越低。降低开路电压的负面影响最大,因此会降低光伏电池板的功率。可提供被动或主动冷却系统来避免温度的负面影响。本文介绍了光伏专用主动冷却系统的原型。这种系统的原型是在克拉科夫 AGH 大学开发的,并在实验室条件下进行了测试。建议的系统配备了风扇,风扇安装在与 70 Wp 光伏板后部相连的板上。测试了该系统的不同配置,包括不同数量的风扇和不同位置的风扇。人工光源产生的辐照值为 770 瓦/平方米。实验中测试的每种变体都达到了这个值。据观察,在实验室条件下,光电板产生的最大功率约为 47.31 W。由于温度升高,功率下降到 40.09 W(当未冷却的光电板表面温度达到 60 °C 时)。另一方面,在相同条件下,配备了所开发冷却系统的光伏电池板的发电功率约为 44.37 W(即比未冷却电池板的发电功率高 10.7%)。根据获得的结果建立了数学模型,并使用 ANSYS Workbench 软件进行了模拟。验证程序结束后,对空气冷却系统的几种配置进行了开发和分析。选择了最突出的情况进行额外的参数分析。确定了最佳风扇方向:垂直倾斜 7°,水平倾斜 10°。对于测试的模块而言,这一修改带来了经济高效的系统(净功率增加约 3.1%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊介绍: ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric. Indexed/​Abstracted: Web of Science SCIE Scopus CAS INSPEC Portico
期刊最新文献
Issue Editorial Masthead Issue Publication Information Celebrating the 90th Birthday of Professor Alan Jay Heeger Bidirectional Magnetization Switching in a Ferrimagnetic Insulator by a Monochiral Cu(II)–Leucine Complex Performance Improvement of the Triboelectric-Electromagnetic Hybrid Generator with a Differential Mechanism by Wind Driving
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1