J. Becker, M. Le Saux, P. Charrier, W. Hervouet, V. Le Saux, L. Maheo, Y. Marco
{"title":"The SFIR Test: An Innovative Hydrostatic Compression Test to Characterize the Volumetric Behavior of Polymeric Foams","authors":"J. Becker, M. Le Saux, P. Charrier, W. Hervouet, V. Le Saux, L. Maheo, Y. Marco","doi":"10.1007/s11340-024-01099-1","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Polymeric foam materials can show a strongly non linear compressible elastic response. For certain applications, it is necessary to know the volumetric behavior of the material under hydrostatic compression. Existing devices for hydrostatic compression testing use a multiaxial testing machine or a fluid to transmit pressure to the foam. They are either complex to set up, or do not allow for hydrostatic pressures of several MPa to be applied or for volume variations of several tens of percent to be achieved. Besides, when pressure is applied to the sample via a fluid, it is difficult to prevent penetration of the fluid into the foam, particularly when it is open-cell.</p><h3>Objective</h3><p>This paper presents a hydrostatic compression test for polymeric foams that does not present these limitations.</p><h3>Methods</h3><p>A cylinder of a nearly incompressible material (silicone) is molded around a spherical sample of the polymeric foam of interest. The whole set is subjected to confined compression in a rigid chamber. Post-processing is developed, based on finite element analysis, to determine the hydrostatic stress in the foam and its volume ratio from the axial load and displacement data.</p><h3>Results</h3><p>Finite element simulations show that the foam sample is subjected to a state close to hydrostatic compression. The test was applied to several samples of elastomeric microcellular polyurethane foams of different densities. The results are in line with expectations, with limited scattering.</p><h3>Conclusions</h3><p>The Sphere Foam In Rubber (SFIR) test allows to reach volume reductions of several tens of percents and hydrostatic stress levels of several MPa, on any kind of polymeric foams, provided that its bulk modulus is at least 100 times lower than that of the surrounding nearly incompressible material used. It can be easily implemented with very standard equipment.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"64 9","pages":"1407 - 1422"},"PeriodicalIF":2.0000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental Mechanics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s11340-024-01099-1","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Polymeric foam materials can show a strongly non linear compressible elastic response. For certain applications, it is necessary to know the volumetric behavior of the material under hydrostatic compression. Existing devices for hydrostatic compression testing use a multiaxial testing machine or a fluid to transmit pressure to the foam. They are either complex to set up, or do not allow for hydrostatic pressures of several MPa to be applied or for volume variations of several tens of percent to be achieved. Besides, when pressure is applied to the sample via a fluid, it is difficult to prevent penetration of the fluid into the foam, particularly when it is open-cell.
Objective
This paper presents a hydrostatic compression test for polymeric foams that does not present these limitations.
Methods
A cylinder of a nearly incompressible material (silicone) is molded around a spherical sample of the polymeric foam of interest. The whole set is subjected to confined compression in a rigid chamber. Post-processing is developed, based on finite element analysis, to determine the hydrostatic stress in the foam and its volume ratio from the axial load and displacement data.
Results
Finite element simulations show that the foam sample is subjected to a state close to hydrostatic compression. The test was applied to several samples of elastomeric microcellular polyurethane foams of different densities. The results are in line with expectations, with limited scattering.
Conclusions
The Sphere Foam In Rubber (SFIR) test allows to reach volume reductions of several tens of percents and hydrostatic stress levels of several MPa, on any kind of polymeric foams, provided that its bulk modulus is at least 100 times lower than that of the surrounding nearly incompressible material used. It can be easily implemented with very standard equipment.
期刊介绍:
Experimental Mechanics is the official journal of the Society for Experimental Mechanics that publishes papers in all areas of experimentation including its theoretical and computational analysis. The journal covers research in design and implementation of novel or improved experiments to characterize materials, structures and systems. Articles extending the frontiers of experimental mechanics at large and small scales are particularly welcome.
Coverage extends from research in solid and fluids mechanics to fields at the intersection of disciplines including physics, chemistry and biology. Development of new devices and technologies for metrology applications in a wide range of industrial sectors (e.g., manufacturing, high-performance materials, aerospace, information technology, medicine, energy and environmental technologies) is also covered.