Calculation of relative luminescent efficiency of TL/OSL detectors to cosmic radiation spectrum in cis-lunar space

IF 1.6 3区 物理与天体物理 Q2 NUCLEAR SCIENCE & TECHNOLOGY Radiation Measurements Pub Date : 2024-08-02 DOI:10.1016/j.radmeas.2024.107264
P. Bilski , D. Matthiä , T. Berger , R. Gaza
{"title":"Calculation of relative luminescent efficiency of TL/OSL detectors to cosmic radiation spectrum in cis-lunar space","authors":"P. Bilski ,&nbsp;D. Matthiä ,&nbsp;T. Berger ,&nbsp;R. Gaza","doi":"10.1016/j.radmeas.2024.107264","DOIUrl":null,"url":null,"abstract":"<div><p>In the MARE experiment onboard the NASA Artemis 1 mission of the ORION spacecraft to lunar orbit, two anthropomorphic female phantoms, equipped with a large number of active and passive radiation detectors were flown. Among the detectors were both LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors as well as Al<sub>2</sub>O<sub>3</sub>:C OSL detectors. In order to correctly interpret the measured doses, the effective relative TL/OSL efficiency for cosmic radiation of these detectors was calculated by combining simulated radiation spectra for the cis-lunar space conditions with the efficiency functions based on experimental data for different ions and on a microdosimetric model.</p><p>The obtained results show that for the ORION shielding conditions, the relative efficiency of LiF:Mg,Ti is close to unity (0.95), while the remaining detectors show somewhat smaller efficiency: 0.90 for Al<sub>2</sub>O<sub>3</sub>:C and (0.81–0.86) for LiF:Mg,Cu,P. The analysis of the influence of the shielding thickness on the relative TL/OSL efficiency revealed, that for low shielding conditions, the relative efficiency may be more significantly decreased, reaching values between 0.71 (LiF:Mg,Cu,P) and 0.85 (LiF:Mg,Ti) for 1 g/cm<sup>2</sup>.</p></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"177 ","pages":"Article 107264"},"PeriodicalIF":1.6000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1350448724002129/pdfft?md5=a2d14bb97f950a5d64d2c8eecb57c5b2&pid=1-s2.0-S1350448724002129-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448724002129","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

In the MARE experiment onboard the NASA Artemis 1 mission of the ORION spacecraft to lunar orbit, two anthropomorphic female phantoms, equipped with a large number of active and passive radiation detectors were flown. Among the detectors were both LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors as well as Al2O3:C OSL detectors. In order to correctly interpret the measured doses, the effective relative TL/OSL efficiency for cosmic radiation of these detectors was calculated by combining simulated radiation spectra for the cis-lunar space conditions with the efficiency functions based on experimental data for different ions and on a microdosimetric model.

The obtained results show that for the ORION shielding conditions, the relative efficiency of LiF:Mg,Ti is close to unity (0.95), while the remaining detectors show somewhat smaller efficiency: 0.90 for Al2O3:C and (0.81–0.86) for LiF:Mg,Cu,P. The analysis of the influence of the shielding thickness on the relative TL/OSL efficiency revealed, that for low shielding conditions, the relative efficiency may be more significantly decreased, reaching values between 0.71 (LiF:Mg,Cu,P) and 0.85 (LiF:Mg,Ti) for 1 g/cm2.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
计算 TL/OSL 探测器对顺月空间宇宙辐射光谱的相对发光效率
在美国航天局 ORION 航天器的 Artemis 1 号月球轨道飞行任务上进行的 MARE 实验中,飞行了两个拟人化的女性模型,模型上装有大量主动和被动辐射探测器。其中包括 LiF:Mg,Ti 和 LiF:Mg,Cu,P TL 探测器以及 AlO:C OSL 探测器。为了正确解释测得的剂量,计算了这些探测器对宇宙辐射的有效相对 TL/OSL 效 率,方法是将顺月球空间条件下的模拟辐射光谱与根据不同离子的实验数据和微量测 量模型得出的效率函数结合起来。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiation Measurements
Radiation Measurements 工程技术-核科学技术
CiteScore
4.10
自引率
20.00%
发文量
116
审稿时长
48 days
期刊介绍: The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal. Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.
期刊最新文献
Editorial Board Development of A handheld pressurized ionization chamber for gamma monitoring Three-dimensional electron paramagnetic resonance (EPR) imaging of an X-ray-irradiated bovine tooth: A feasibility study Compton-camera-based radiopharmaceutical imaging with an attenuation-corrected LM-MLEM reconstruction strategy Feasibility study on dose conversion using a deep learning algorithm for retrospective dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1