{"title":"Dynamic J-A model improved by waveform scale parameters and R-L type fractional derivatives","authors":"Long Chen, Zheyu Zhang, Ni An, Xin Wen, Tong Ben","doi":"10.1108/compel-01-2024-0027","DOIUrl":null,"url":null,"abstract":"<h3>Purpose</h3>\n<p>The purpose of this study is to model the global dynamic hysteresis properties with an improved Jiles–Atherton (J-A) model through a unified set of parameters.</p><!--/ Abstract__block -->\n<h3>Design/methodology/approach</h3>\n<p>First, the waveform scaling parameters <em>β</em>, <em>λ<sub>k</sub></em> and <em>λ<sub>c</sub></em> are used to improve the calculation accuracy of hysteresis loops at low magnetic flux density. Second, the Riemann–Liouville (R-L) type fractional derivatives technique is applied to modified static inverse J-A model to compute the dynamic magnetic field considering the skin effect in wideband frequency magnetization conditions.</p><!--/ Abstract__block -->\n<h3>Findings</h3>\n<p>The proposed model is identified and verified by modeling the hysteresis loops whose maximum magnetic flux densities vary from 0.3 to 1.4 T up to 800 Hz using B30P105 electrical steel. Compared with the conventional J-A model, the global simulation ability of the proposed dynamic model is much improved.</p><!--/ Abstract__block -->\n<h3>Originality/value</h3>\n<p>Accurate modeling of the hysteresis properties of electrical steels is essential for analyzing the loss behavior of electrical equipment in finite element analysis (FEA). Nevertheless, the existing inverse Jiles–Atherton (J-A) model can only guarantee the simulation accuracy with higher magnetic flux densities, which cannot guarantee the analysis requirements of considering both low magnetic flux density and high magnetic flux density in FEA. This paper modifies the dynamic J-A model by introducing waveform scaling parameters and the R-L fractional derivative to improve the hysteresis loops’ simulation accuracy from low to high magnetic flux densities with the same set of parameters in a wide frequency range.</p><!--/ Abstract__block -->","PeriodicalId":501376,"journal":{"name":"COMPEL","volume":"44 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"COMPEL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/compel-01-2024-0027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
The purpose of this study is to model the global dynamic hysteresis properties with an improved Jiles–Atherton (J-A) model through a unified set of parameters.
Design/methodology/approach
First, the waveform scaling parameters β, λk and λc are used to improve the calculation accuracy of hysteresis loops at low magnetic flux density. Second, the Riemann–Liouville (R-L) type fractional derivatives technique is applied to modified static inverse J-A model to compute the dynamic magnetic field considering the skin effect in wideband frequency magnetization conditions.
Findings
The proposed model is identified and verified by modeling the hysteresis loops whose maximum magnetic flux densities vary from 0.3 to 1.4 T up to 800 Hz using B30P105 electrical steel. Compared with the conventional J-A model, the global simulation ability of the proposed dynamic model is much improved.
Originality/value
Accurate modeling of the hysteresis properties of electrical steels is essential for analyzing the loss behavior of electrical equipment in finite element analysis (FEA). Nevertheless, the existing inverse Jiles–Atherton (J-A) model can only guarantee the simulation accuracy with higher magnetic flux densities, which cannot guarantee the analysis requirements of considering both low magnetic flux density and high magnetic flux density in FEA. This paper modifies the dynamic J-A model by introducing waveform scaling parameters and the R-L fractional derivative to improve the hysteresis loops’ simulation accuracy from low to high magnetic flux densities with the same set of parameters in a wide frequency range.