Farnoosh Ghorbani, Parisa Koohsari, Mehdi Yaseri, Nasim Tootoonchi, Zeinab Aryanian, Atefeh Vahedi, Ifa Etesami
{"title":"Laser hair removal complications and the associated risk factors at a tertiary dermatology center: a case-control study.","authors":"Farnoosh Ghorbani, Parisa Koohsari, Mehdi Yaseri, Nasim Tootoonchi, Zeinab Aryanian, Atefeh Vahedi, Ifa Etesami","doi":"10.1007/s10103-024-04169-x","DOIUrl":null,"url":null,"abstract":"<p><p>Laser hair removal (LHR) has been established as a safe and efficient method for eliminating unwanted hair. This study aimed to investigate the frequency of LHR complications and assess the contributing factors. During one year, 16,900 patients undergoing LHR therapy were evaluated for complications. For each case, two external controls were selected (matched based on age, sex, Fitzpatrick skin type (FST) III-IV, and the treated anatomical region). To assess the impact of anatomical region on complication occurrence, each patient was used as their internal control if another area was treated during the same session. GEE analysis was used for statistical analysis.The incidence of LHR complications was calculated to be 0.69%. The most common complications were petechia, purpura, and ecchymosis (31.66%) followed by pigmentation changes (20.0%). LHR complications were most commonly observed in the lower limbs (32.0%), face and neck (23.3%), and genitalia and thighs (22.3%), respectively. Possible risk factors were younger age (OR = 0.74, P-value ≤ 0.001), operating LHR in the head and neck (OR = 5.8, P-value = 0.022), utilization of the alexandrite laser (OR = 2.32, P-value = 0.011), and fluence in the Alexandrite laser (OR = 3.47, P-value = 0.003).Overall, the results of this study indicate that LHR is generally a safe method for removing unwanted hair. However, factors such as younger age, treatment of the facial area, and use of the alexandrite laser especially with higher fluence levels in patients with FST III-IV were identified as potential risk factors.</p>","PeriodicalId":17978,"journal":{"name":"Lasers in Medical Science","volume":"39 1","pages":"218"},"PeriodicalIF":2.1000,"publicationDate":"2024-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lasers in Medical Science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10103-024-04169-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Laser hair removal (LHR) has been established as a safe and efficient method for eliminating unwanted hair. This study aimed to investigate the frequency of LHR complications and assess the contributing factors. During one year, 16,900 patients undergoing LHR therapy were evaluated for complications. For each case, two external controls were selected (matched based on age, sex, Fitzpatrick skin type (FST) III-IV, and the treated anatomical region). To assess the impact of anatomical region on complication occurrence, each patient was used as their internal control if another area was treated during the same session. GEE analysis was used for statistical analysis.The incidence of LHR complications was calculated to be 0.69%. The most common complications were petechia, purpura, and ecchymosis (31.66%) followed by pigmentation changes (20.0%). LHR complications were most commonly observed in the lower limbs (32.0%), face and neck (23.3%), and genitalia and thighs (22.3%), respectively. Possible risk factors were younger age (OR = 0.74, P-value ≤ 0.001), operating LHR in the head and neck (OR = 5.8, P-value = 0.022), utilization of the alexandrite laser (OR = 2.32, P-value = 0.011), and fluence in the Alexandrite laser (OR = 3.47, P-value = 0.003).Overall, the results of this study indicate that LHR is generally a safe method for removing unwanted hair. However, factors such as younger age, treatment of the facial area, and use of the alexandrite laser especially with higher fluence levels in patients with FST III-IV were identified as potential risk factors.
期刊介绍:
Lasers in Medical Science (LIMS) has established itself as the leading international journal in the rapidly expanding field of medical and dental applications of lasers and light. It provides a forum for the publication of papers on the technical, experimental, and clinical aspects of the use of medical lasers, including lasers in surgery, endoscopy, angioplasty, hyperthermia of tumors, and photodynamic therapy. In addition to medical laser applications, LIMS presents high-quality manuscripts on a wide range of dental topics, including aesthetic dentistry, endodontics, orthodontics, and prosthodontics.
The journal publishes articles on the medical and dental applications of novel laser technologies, light delivery systems, sensors to monitor laser effects, basic laser-tissue interactions, and the modeling of laser-tissue interactions. Beyond laser applications, LIMS features articles relating to the use of non-laser light-tissue interactions.