{"title":"[Radiation Dose Considerations for Breast Sonographers Following <sup>99m</sup>Tc-HMDP Bone Scan Administration].","authors":"Ryota Tsukada, Kei Wagatsuma, Hiroaki Suzuki","doi":"10.6009/jjrt.2024-1434","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Patients who were administered radiopharmaceuticals can be a source of radiation exposure to sonographers. This study aimed to identify factors associated with radiation exposure to breast sonographers from patients administered radiopharmaceuticals for bone scanning.</p><p><strong>Methods: </strong>The exposure dose of six sonographers was measured during breast sonography in 59 patients administered <sup>99m</sup>Tc-HMDP. We predicted the following factors to be related to exposure dose: time interval between administration and sonography, sonography examination time, estimated radioactivity at sonography, sonographer's years of experience, and patients' clinical data (age, renal function and surgical procedure). Spearman's rank correlation coefficient was used to examine the relationship between radiation dose and the aforementioned factors.</p><p><strong>Results: </strong>The mean±standard deviation of the exposure dose for the sonographers was 9.3±3.8 µSv. The time interval between administering the radiopharmaceutical agent and sonography, the sonography examination time and estimated radioactivity at sonography were found to be factors related to the exposure of the sonographer. The exposure dose increased as a function of the shorter time interval, longer examination time and higher estimated radioactivity at sonography.</p><p><strong>Conclusion: </strong>The time interval between drug administration and sonography, sonography examination time and estimated radioactivity at sonography contributed to the increased dose to breast sonographers. Although we considered that the exposure dose of sonographers would not possibly exceed the dose limit in the present study, we suggested that radiological technologists need to educate the physicians requesting sonography, and the sonographers about the radiation exposure in nuclear medicine.</p>","PeriodicalId":74309,"journal":{"name":"Nihon Hoshasen Gijutsu Gakkai zasshi","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Hoshasen Gijutsu Gakkai zasshi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6009/jjrt.2024-1434","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Patients who were administered radiopharmaceuticals can be a source of radiation exposure to sonographers. This study aimed to identify factors associated with radiation exposure to breast sonographers from patients administered radiopharmaceuticals for bone scanning.
Methods: The exposure dose of six sonographers was measured during breast sonography in 59 patients administered 99mTc-HMDP. We predicted the following factors to be related to exposure dose: time interval between administration and sonography, sonography examination time, estimated radioactivity at sonography, sonographer's years of experience, and patients' clinical data (age, renal function and surgical procedure). Spearman's rank correlation coefficient was used to examine the relationship between radiation dose and the aforementioned factors.
Results: The mean±standard deviation of the exposure dose for the sonographers was 9.3±3.8 µSv. The time interval between administering the radiopharmaceutical agent and sonography, the sonography examination time and estimated radioactivity at sonography were found to be factors related to the exposure of the sonographer. The exposure dose increased as a function of the shorter time interval, longer examination time and higher estimated radioactivity at sonography.
Conclusion: The time interval between drug administration and sonography, sonography examination time and estimated radioactivity at sonography contributed to the increased dose to breast sonographers. Although we considered that the exposure dose of sonographers would not possibly exceed the dose limit in the present study, we suggested that radiological technologists need to educate the physicians requesting sonography, and the sonographers about the radiation exposure in nuclear medicine.