Best evidence topic report: are portable handheld fundus cameras effective in diagnosing diabetic retinopathy in emergency settings?

IF 2.7 3区 医学 Q1 EMERGENCY MEDICINE Emergency Medicine Journal Pub Date : 2024-11-21 DOI:10.1136/emermed-2024-214236
Mohammadreza Arzaghi, Mostafa Alavi-Moghaddam
{"title":"Best evidence topic report: are portable handheld fundus cameras effective in diagnosing diabetic retinopathy in emergency settings?","authors":"Mohammadreza Arzaghi, Mostafa Alavi-Moghaddam","doi":"10.1136/emermed-2024-214236","DOIUrl":null,"url":null,"abstract":"<p><p>A short-cut systematic review was conducted using a described protocol. The three-part question addressed was: In adult patients presenting to the ED with diabetes-related visual symptoms, how effective is using a portable handheld fundus camera in diagnosing diabetic retinopathy?MEDLINE, Embase and Cochrane databases were searched for relevant evidence. Altogether, 237 papers were found using the search strategy developed. 12 provided the best evidence to answer the three-part question. The data on first author name, publication year, country of origin, study type, study sample size, participant's gender, reported effect sizes, main findings and limitations were extracted from the relevant studies and listed in a table.Following a thorough examination and review of the literature, our analysis identified 12 articles for detailed evaluation. Of these, three provided the most compelling evidence concerning the use of portable handheld fundus cameras for the diagnosis of diabetic retinopathy in emergency settings. Ruan <i>et al</i> (2022) reported superior image quality and a sensitivity of 82.1% (95% CI: 72.1% to 92.2%) with a specificity of 97.4% (95% CI: 95.4% to 99.5%) for a handheld camera combined with artificial intelligence interpretation. Jin <i>et al</i> (2017) demonstrated high-quality images with 63% rated as excellent, showing a comparable efficacy to a traditional tabletop camera. Das <i>et al</i> (2022) found that Remidio and Pictor handheld cameras had high success rates and image quality, with sensitivities of 77.5% (95% CI: 65.9% to 89.0%) and 78.1% (95% CI: 66.6% to 89.5%), respectively, comparable to the Zeiss tabletop camera's sensitivity of 84.9% (95% CI: 78.2% to 91.5%). The clinical bottom line is that the best available evidence supports the effectiveness of portable handheld fundus cameras for diagnosing diabetic retinopathy in emergency settings.</p>","PeriodicalId":11532,"journal":{"name":"Emergency Medicine Journal","volume":" ","pages":"764-766"},"PeriodicalIF":2.7000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emergency Medicine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/emermed-2024-214236","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

A short-cut systematic review was conducted using a described protocol. The three-part question addressed was: In adult patients presenting to the ED with diabetes-related visual symptoms, how effective is using a portable handheld fundus camera in diagnosing diabetic retinopathy?MEDLINE, Embase and Cochrane databases were searched for relevant evidence. Altogether, 237 papers were found using the search strategy developed. 12 provided the best evidence to answer the three-part question. The data on first author name, publication year, country of origin, study type, study sample size, participant's gender, reported effect sizes, main findings and limitations were extracted from the relevant studies and listed in a table.Following a thorough examination and review of the literature, our analysis identified 12 articles for detailed evaluation. Of these, three provided the most compelling evidence concerning the use of portable handheld fundus cameras for the diagnosis of diabetic retinopathy in emergency settings. Ruan et al (2022) reported superior image quality and a sensitivity of 82.1% (95% CI: 72.1% to 92.2%) with a specificity of 97.4% (95% CI: 95.4% to 99.5%) for a handheld camera combined with artificial intelligence interpretation. Jin et al (2017) demonstrated high-quality images with 63% rated as excellent, showing a comparable efficacy to a traditional tabletop camera. Das et al (2022) found that Remidio and Pictor handheld cameras had high success rates and image quality, with sensitivities of 77.5% (95% CI: 65.9% to 89.0%) and 78.1% (95% CI: 66.6% to 89.5%), respectively, comparable to the Zeiss tabletop camera's sensitivity of 84.9% (95% CI: 78.2% to 91.5%). The clinical bottom line is that the best available evidence supports the effectiveness of portable handheld fundus cameras for diagnosing diabetic retinopathy in emergency settings.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
最佳证据专题报告:便携式手持眼底照相机是否能在紧急情况下有效诊断糖尿病视网膜病变?
我们按照描述的方案进行了一次捷径式系统综述。所涉及的问题包括三个部分:在急诊室就诊并伴有糖尿病相关视力症状的成年患者中,使用便携式手持眼底照相机诊断糖尿病视网膜病变的效果如何?根据制定的检索策略,共找到 237 篇论文。其中 12 篇提供了回答三部分问题的最佳证据。我们从相关研究中提取了第一作者姓名、发表年份、原籍国、研究类型、研究样本量、参与者性别、报告的效应大小、主要发现和局限性等数据,并将其列于表格中。在这些文章中,有三篇提供了在紧急情况下使用便携式手持眼底照相机诊断糖尿病视网膜病变的最有力证据。Ruan 等人(2022 年)报告称,结合人工智能判读的手持式照相机图像质量上乘,灵敏度为 82.1%(95% CI:72.1% 至 92.2%),特异性为 97.4%(95% CI:95.4% 至 99.5%)。Jin 等人(2017 年)展示了高质量的图像,63% 的图像被评为优秀,显示出与传统台式照相机相当的功效。Das 等人(2022 年)发现,Remidio 和 Pictor 手持式相机具有较高的成功率和图像质量,灵敏度分别为 77.5%(95% CI:65.9% 至 89.0%)和 78.1%(95% CI:66.6% 至 89.5%),与蔡司台式相机 84.9%(95% CI:78.2% 至 91.5%)的灵敏度相当。临床结果表明,现有的最佳证据支持便携式手持眼底照相机在紧急情况下诊断糖尿病视网膜病变的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Emergency Medicine Journal
Emergency Medicine Journal 医学-急救医学
CiteScore
4.40
自引率
6.50%
发文量
262
审稿时长
3-8 weeks
期刊介绍: The Emergency Medicine Journal is a leading international journal reporting developments and advances in emergency medicine and acute care. It has relevance to all specialties involved in the management of emergencies in the hospital and prehospital environment. Each issue contains editorials, reviews, original research, evidence based reviews, letters and more.
期刊最新文献
Conservative management of traumatic haemothoraces: a UK single-centre trauma unit retrospective audit. Emerging technology solutions to support national emergency workforce capacity-building initiatives: lessons from Ugandan policy and practice. Objective capillary refill to rapidly detect haemorrhage at the bedside. Olanzapine postinjection delirium/sedation syndrome after long-acting olanzapine depot injection presenting to the emergency department: practical guidelines for diagnosis and management. Best evidence topic report: are portable handheld fundus cameras effective in diagnosing diabetic retinopathy in emergency settings?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1