{"title":"A new calibration method for radon detector in seismic systems","authors":"Hongwei Ren , Yaowei Liu","doi":"10.1016/j.eqs.2024.06.001","DOIUrl":null,"url":null,"abstract":"<div><p>Radon observation is an important measurement item of seismic precursor network observation. The radon detector calibration is a key technical link for ensuring radon observation accuracy. At present, the radon detector calibration in seismic systems in China is faced with a series of bottleneck problems, such as aging and scrap, acquisition difficulties, high supervision costs, and transportation limitations of radon sources. As a result, a large number of radon detectors cannot be accurately calibrated regularly, seriously affecting the accuracy and reliability of radon observation data in China. To solve this problem, a new calibration method for radon detectors was established. The advantage of this method is that the dangerous radioactive substance, i.e., the radon source, can be avoided, but only “standard instruments” and water samples with certain dissolved radon concentrations can be used to realize radon detector calibration. This method avoids the risk of radioactive leakage and solves the current widespread difficulties and bottleneck of radon detector calibration in seismic systems in China. The comparison experiment with the traditional calibration method shows that the error of the calibration coefficient obtained by the new method is less than 5% compared with that by the traditional method, which meets the requirements of seismic observation systems, confirming the reliability of the new method. This new method can completely replace the traditional calibration method of using a radon source in seismic systems.</p></div>","PeriodicalId":46333,"journal":{"name":"Earthquake Science","volume":"37 5","pages":"Pages 445-458"},"PeriodicalIF":1.2000,"publicationDate":"2024-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1674451924000612/pdfft?md5=57db9f4e2947e9ef8657cdc44b9359c2&pid=1-s2.0-S1674451924000612-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Earthquake Science","FirstCategoryId":"89","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1674451924000612","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Earth and Planetary Sciences","Score":null,"Total":0}
引用次数: 0
Abstract
Radon observation is an important measurement item of seismic precursor network observation. The radon detector calibration is a key technical link for ensuring radon observation accuracy. At present, the radon detector calibration in seismic systems in China is faced with a series of bottleneck problems, such as aging and scrap, acquisition difficulties, high supervision costs, and transportation limitations of radon sources. As a result, a large number of radon detectors cannot be accurately calibrated regularly, seriously affecting the accuracy and reliability of radon observation data in China. To solve this problem, a new calibration method for radon detectors was established. The advantage of this method is that the dangerous radioactive substance, i.e., the radon source, can be avoided, but only “standard instruments” and water samples with certain dissolved radon concentrations can be used to realize radon detector calibration. This method avoids the risk of radioactive leakage and solves the current widespread difficulties and bottleneck of radon detector calibration in seismic systems in China. The comparison experiment with the traditional calibration method shows that the error of the calibration coefficient obtained by the new method is less than 5% compared with that by the traditional method, which meets the requirements of seismic observation systems, confirming the reliability of the new method. This new method can completely replace the traditional calibration method of using a radon source in seismic systems.
期刊介绍:
Earthquake Science (EQS) aims to publish high-quality, original, peer-reviewed articles on earthquake-related research subjects. It is an English international journal sponsored by the Seismological Society of China and the Institute of Geophysics, China Earthquake Administration.
The topics include, but not limited to, the following
● Seismic sources of all kinds.
● Earth structure at all scales.
● Seismotectonics.
● New methods and theoretical seismology.
● Strong ground motion.
● Seismic phenomena of all kinds.
● Seismic hazards, earthquake forecasting and prediction.
● Seismic instrumentation.
● Significant recent or past seismic events.
● Documentation of recent seismic events or important observations.
● Descriptions of field deployments, new methods, and available software tools.
The types of manuscripts include the following. There is no length requirement, except for the Short Notes.
【Articles】 Original contributions that have not been published elsewhere.
【Short Notes】 Short papers of recent events or topics that warrant rapid peer reviews and publications. Limited to 4 publication pages.
【Rapid Communications】 Significant contributions that warrant rapid peer reviews and publications.
【Review Articles】Review articles are by invitation only. Please contact the editorial office and editors for possible proposals.
【Toolboxes】 Descriptions of novel numerical methods and associated computer codes.
【Data Products】 Documentation of datasets of various kinds that are interested to the community and available for open access (field data, processed data, synthetic data, or models).
【Opinions】Views on important topics and future directions in earthquake science.
【Comments and Replies】Commentaries on a recently published EQS paper is welcome. The authors of the paper commented will be invited to reply. Both the Comment and the Reply are subject to peer review.