Guido Ascione, Giovanni Rossini, Davide Schiavi, Nicolò Azzola Guicciardi, Matteo Saccocci, Nicola Buzzatti, Cosmo Godino, Ottavio Alfieri, Eustachio Agricola, Francesco Maisano, Paolo Denti
{"title":"Remote proctoring during structural heart procedures: Toward a widespread diffusion of knowledge using mixed reality.","authors":"Guido Ascione, Giovanni Rossini, Davide Schiavi, Nicolò Azzola Guicciardi, Matteo Saccocci, Nicola Buzzatti, Cosmo Godino, Ottavio Alfieri, Eustachio Agricola, Francesco Maisano, Paolo Denti","doi":"10.1002/ccd.31187","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Despite its wide diffusion in surgical procedures, very few experiences are reported so far about the possible applications of remote proctoring (RP) in structural heart interventions.</p><p><strong>Aims: </strong>Our aim was to demonstrate the feasibility, safety, and efficacy of RP during transcatheter edge-to-edge repair using a mixed reality-based head-mounted display (HMD).</p><p><strong>Methods: </strong>Two users (a doctor and a proctor), wearing HMDs, were connected through a 5G network, allowing them to share audio and video signals. During the procedure, the proctor was located in a contiguous room, without any direct connection with the operator. The primary endpoint was noninferiority of HMD-mediated interaction if compared with direct in-person interaction. It was assessed using an operator-proctor interaction test based on six questions asked by the doctor to the proctor on six key procedural steps.</p><p><strong>Results: </strong>Between September 2021 and April 2022, nine patients were enrolled in the study (15 clips delivered). The primary endpoint was reached in 9/15 clips implanted (60%). The first three failures were due to a chat software problem, and the others were linked with a 5G network malfunction. However, the HMD and its mixed reality tools were well tolerated by the operators, and no interference with the procedure was registered in any of the cases.</p><p><strong>Conclusions: </strong>In our experience, RP during structural heart interventions is feasible and efficacious. Wearing the HMD is comfortable and does not affect safety and effectiveness of interventional procedures. However, especially if considering a wide geographic use of this tool, a stable internet connection is imperative.</p>","PeriodicalId":9650,"journal":{"name":"Catheterization and Cardiovascular Interventions","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and Cardiovascular Interventions","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ccd.31187","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Despite its wide diffusion in surgical procedures, very few experiences are reported so far about the possible applications of remote proctoring (RP) in structural heart interventions.
Aims: Our aim was to demonstrate the feasibility, safety, and efficacy of RP during transcatheter edge-to-edge repair using a mixed reality-based head-mounted display (HMD).
Methods: Two users (a doctor and a proctor), wearing HMDs, were connected through a 5G network, allowing them to share audio and video signals. During the procedure, the proctor was located in a contiguous room, without any direct connection with the operator. The primary endpoint was noninferiority of HMD-mediated interaction if compared with direct in-person interaction. It was assessed using an operator-proctor interaction test based on six questions asked by the doctor to the proctor on six key procedural steps.
Results: Between September 2021 and April 2022, nine patients were enrolled in the study (15 clips delivered). The primary endpoint was reached in 9/15 clips implanted (60%). The first three failures were due to a chat software problem, and the others were linked with a 5G network malfunction. However, the HMD and its mixed reality tools were well tolerated by the operators, and no interference with the procedure was registered in any of the cases.
Conclusions: In our experience, RP during structural heart interventions is feasible and efficacious. Wearing the HMD is comfortable and does not affect safety and effectiveness of interventional procedures. However, especially if considering a wide geographic use of this tool, a stable internet connection is imperative.
期刊介绍:
Catheterization and Cardiovascular Interventions is an international journal covering the broad field of cardiovascular diseases. Subject material includes basic and clinical information that is derived from or related to invasive and interventional coronary or peripheral vascular techniques. The journal focuses on material that will be of immediate practical value to physicians providing patient care in the clinical laboratory setting. To accomplish this, the journal publishes Preliminary Reports and Work In Progress articles that complement the traditional Original Studies, Case Reports, and Comprehensive Reviews. Perspective and insight concerning controversial subjects and evolving technologies are provided regularly through Editorial Commentaries furnished by members of the Editorial Board and other experts. Articles are subject to double-blind peer review and complete editorial evaluation prior to any decision regarding acceptability.