An accelerated PETALUTE MRI sequence for in vivo quantification of sodium content in human articular cartilage at 3T.

IF 1.9 3区 医学 Q2 ORTHOPEDICS Skeletal Radiology Pub Date : 2024-08-17 DOI:10.1007/s00256-024-04774-5
Cameron X Villarreal, Xin Shen, Ahmad A Alhulail, Nicholas M Buffo, Xiaopeng Zhou, Evan Pogue, Ali Caglar Özen, Mark Chiew, Stephen Sawiak, Uzay Emir, Deva D Chan
{"title":"An accelerated PETALUTE MRI sequence for in vivo quantification of sodium content in human articular cartilage at 3T.","authors":"Cameron X Villarreal, Xin Shen, Ahmad A Alhulail, Nicholas M Buffo, Xiaopeng Zhou, Evan Pogue, Ali Caglar Özen, Mark Chiew, Stephen Sawiak, Uzay Emir, Deva D Chan","doi":"10.1007/s00256-024-04774-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In this work, we evaluate the sodium magnetic resonance imaging (MRI) capabilities of a three-dimensional (3D) dual-echo ultrashort echo time (UTE) sequence with a novel rosette petal trajectory (PETALUTE), in comparison to the 3D density-adapted (DA) radial spokes UTE sequence in human articular cartilage in the knee.</p><p><strong>Materials and methods: </strong>We scanned five healthy subjects using a 3D dual-echo PETALUTE acquisition and two comparable implementations of 3D DA-radial spokes acquisitions, one matching the number of k-space projections (Radial - Matched Spokes) and the other matching the total number of samples (Radial - Matched Samples) acquired in k-space.</p><p><strong>Results: </strong>The PETALUTE acquisition enabled equivalent sodium quantification in articular cartilage volumes of interest (168.8 ± 29.9 mM, mean ± standard deviation) to those derived from the 3D radial acquisitions (171.62 ± 28.7 mM and 149.8 ± 22.2 mM, respectively). We achieved a 41% shorter scan time of 2:06 for 3D PETALUTE, compared to 3:36 for 3D radial acquisitions. We also evaluated the feasibility of further acceleration of the PETALUTE sequence through retrospective compressed sensing with 2 × and 4 × acceleration of the first echo and showed structural similarity of 0.89 ± 0.03 and 0.87 ± 0.03 when compared to non-retrospectively accelerated reconstruction.</p><p><strong>Conclusion: </strong>We demonstrate improved scan time with equivalent performance using a 3D dual-echo PETALUTE sequence compared to the 3D DA-radial sequence for sodium MRI of articular cartilage.</p>","PeriodicalId":21783,"journal":{"name":"Skeletal Radiology","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Skeletal Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00256-024-04774-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In this work, we evaluate the sodium magnetic resonance imaging (MRI) capabilities of a three-dimensional (3D) dual-echo ultrashort echo time (UTE) sequence with a novel rosette petal trajectory (PETALUTE), in comparison to the 3D density-adapted (DA) radial spokes UTE sequence in human articular cartilage in the knee.

Materials and methods: We scanned five healthy subjects using a 3D dual-echo PETALUTE acquisition and two comparable implementations of 3D DA-radial spokes acquisitions, one matching the number of k-space projections (Radial - Matched Spokes) and the other matching the total number of samples (Radial - Matched Samples) acquired in k-space.

Results: The PETALUTE acquisition enabled equivalent sodium quantification in articular cartilage volumes of interest (168.8 ± 29.9 mM, mean ± standard deviation) to those derived from the 3D radial acquisitions (171.62 ± 28.7 mM and 149.8 ± 22.2 mM, respectively). We achieved a 41% shorter scan time of 2:06 for 3D PETALUTE, compared to 3:36 for 3D radial acquisitions. We also evaluated the feasibility of further acceleration of the PETALUTE sequence through retrospective compressed sensing with 2 × and 4 × acceleration of the first echo and showed structural similarity of 0.89 ± 0.03 and 0.87 ± 0.03 when compared to non-retrospectively accelerated reconstruction.

Conclusion: We demonstrate improved scan time with equivalent performance using a 3D dual-echo PETALUTE sequence compared to the 3D DA-radial sequence for sodium MRI of articular cartilage.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
加速 PETALUTE 核磁共振成像序列,用于在 3T 下活体量化人体关节软骨中的钠含量。
目的:在这项工作中,我们评估了具有新型花瓣轨迹(PETALUTE)的三维(3D)双回波超短回波时间(UTE)序列与三维密度适应(DA)径向辐条UTE序列在人体膝关节软骨中的钠磁共振成像(MRI)能力:我们使用三维双回波PETALUTE采集和两种可比较的三维DA-径向辐条采集方法对五名健康受试者进行了扫描,其中一种方法与k空间投影数(径向-匹配辐条)相匹配,另一种方法与k空间采集的样本总数(径向-匹配样本)相匹配:结果:PETALUTE 采集的相关关节软骨体积中的钠含量(168.8 ± 29.9 mM,平均值 ± 标准偏差)与三维径向采集的钠含量(分别为 171.62 ± 28.7 mM 和 149.8 ± 22.2 mM)相当。三维 PETALUTE 扫描时间为 2:06,比三维径向采集的 3:36 扫描时间缩短了 41%。我们还评估了通过回溯压缩传感进一步加速 PETALUTE 序列的可行性,对第一次回波进行了 2 倍和 4 倍加速,结果显示,与非回溯加速重建相比,结构相似度分别为 0.89 ± 0.03 和 0.87 ± 0.03:我们证明,在关节软骨钠核磁共振成像中,使用三维双回波 PETALUTE 序列与三维 DA-radial 序列相比,扫描时间更短,性能相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Skeletal Radiology
Skeletal Radiology 医学-核医学
CiteScore
4.40
自引率
9.50%
发文量
253
审稿时长
3-8 weeks
期刊介绍: Skeletal Radiology provides a forum for the dissemination of current knowledge and information dealing with disorders of the musculoskeletal system including the spine. While emphasizing the radiological aspects of the many varied skeletal abnormalities, the journal also adopts an interdisciplinary approach, reflecting the membership of the International Skeletal Society. Thus, the anatomical, pathological, physiological, clinical, metabolic and epidemiological aspects of the many entities affecting the skeleton receive appropriate consideration. This is the Journal of the International Skeletal Society and the Official Journal of the Society of Skeletal Radiology and the Australasian Musculoskelelal Imaging Group.
期刊最新文献
Annual scientific meeting of the Australasian Musculoskeletal Imaging Group (AMSIG) 2024, Queensland, Australia. Severe metallosis following catastrophic failure of total shoulder arthroplasty - a case report. Phalangeal microgeodic syndrome: a paediatric case series. Rare presentation of a primary intraosseous glomus tumor in the humerus of a teenager. Extremity radiographs derived from low-dose ultra-high-resolution CT: a phantom study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1