The influence of cathodic materials and optimization of the removal of the chromium (VI) from tannery wastewater by electrocoagulation

Romuald Teguia Doumbi , Jean Olivier Kowe , Domga , Djonga weldi Gnowe , Guy Bertrand Noumi
{"title":"The influence of cathodic materials and optimization of the removal of the chromium (VI) from tannery wastewater by electrocoagulation","authors":"Romuald Teguia Doumbi ,&nbsp;Jean Olivier Kowe ,&nbsp;Domga ,&nbsp;Djonga weldi Gnowe ,&nbsp;Guy Bertrand Noumi","doi":"10.1016/j.clwat.2024.100032","DOIUrl":null,"url":null,"abstract":"<div><p>The present work focuses on the optimization of the removal percentage of Chromium (VI) from a real tannery effluent by electrocoagulation process (EC). The influence of high efficiency cathodic materials (titanium and nickel) was also investigated in this work. The tannery effluent is from the town of Maroua in the Far North Region in Cameroon. The effectiveness of the main operational parameters such as current intensity, initial Cr (VI) concentration, initial pH as well as solution conductivity was examined. All experiments were carried out in an electrocoagulation cell with an effective volume of 400 mL using two electrode combinations as anode/cathode (Al/Ti and Al/Ni). It was found that the Al/Ti combination exhibits higher removal efficiency than Al/Ni under the same operational conditions. Cr (VI) removal efficiencies of 90.93 % and 84.30 % were respectively observed for the Al/Ti and Al/Ni electrodes with an optimal initial pH (pH=6). The maximum current intensity, the maximum initial Cr (VI) concentration as well as the NaCl concentration were 0.4 A, 10 mg/L Cr(VI) and 1.5 g/L respectively. Response surface methodology by the mean of central composite design was performed. The influence of current intensity (100–300 mA), electrolysis time (10–30 min) and interelectrode spacing (1–3 cm), the probability and the mathematical model were highly discussed. According to the experimental design results, the removal of Cr (VI) in the real tannery effluent was up to 99.58 %. For the aforementioned efficiency it requires the optimum values of 211.891 mA, 36.8179 min and 1.609 cm for current intensity, time and the interelectrode spacing, respectively. EC has shown to be easy to operate, to be economic by using cheaper electrodes and efficient for the treatment of real tannery effluent.</p></div>","PeriodicalId":100257,"journal":{"name":"Cleaner Water","volume":"2 ","pages":"Article 100032"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2950263224000309/pdfft?md5=5c4e074ba3ee71a2cb02dab3160f6f11&pid=1-s2.0-S2950263224000309-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cleaner Water","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2950263224000309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The present work focuses on the optimization of the removal percentage of Chromium (VI) from a real tannery effluent by electrocoagulation process (EC). The influence of high efficiency cathodic materials (titanium and nickel) was also investigated in this work. The tannery effluent is from the town of Maroua in the Far North Region in Cameroon. The effectiveness of the main operational parameters such as current intensity, initial Cr (VI) concentration, initial pH as well as solution conductivity was examined. All experiments were carried out in an electrocoagulation cell with an effective volume of 400 mL using two electrode combinations as anode/cathode (Al/Ti and Al/Ni). It was found that the Al/Ti combination exhibits higher removal efficiency than Al/Ni under the same operational conditions. Cr (VI) removal efficiencies of 90.93 % and 84.30 % were respectively observed for the Al/Ti and Al/Ni electrodes with an optimal initial pH (pH=6). The maximum current intensity, the maximum initial Cr (VI) concentration as well as the NaCl concentration were 0.4 A, 10 mg/L Cr(VI) and 1.5 g/L respectively. Response surface methodology by the mean of central composite design was performed. The influence of current intensity (100–300 mA), electrolysis time (10–30 min) and interelectrode spacing (1–3 cm), the probability and the mathematical model were highly discussed. According to the experimental design results, the removal of Cr (VI) in the real tannery effluent was up to 99.58 %. For the aforementioned efficiency it requires the optimum values of 211.891 mA, 36.8179 min and 1.609 cm for current intensity, time and the interelectrode spacing, respectively. EC has shown to be easy to operate, to be economic by using cheaper electrodes and efficient for the treatment of real tannery effluent.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
阴极材料的影响及电凝法去除制革废水中铬(VI)的优化方案
本研究的重点是通过电凝工艺(EC)优化实际制革厂废水中铬(VI)的去除率。这项工作还研究了高效阴极材料(钛和镍)的影响。制革废水来自喀麦隆远北地区的马鲁阿镇。研究了电流强度、初始 Cr (VI) 浓度、初始 pH 值以及溶液电导率等主要操作参数的有效性。所有实验均在一个有效容积为 400 毫升的电凝池中进行,使用两种电极组合作为阳极/阴极(Al/Ti 和 Al/Ni)。实验发现,在相同的操作条件下,Al/Ti 组合的去除效率高于 Al/Ni。在最佳初始 pH 值(pH=6)条件下,Al/Ti 和 Al/Ni 电极对六价铬的去除率分别为 90.93% 和 84.30%。最大电流强度、最大初始六价铬浓度和 NaCl 浓度分别为 0.4 A、10 mg/L 六价铬和 1.5 g/L。采用中心复合设计的响应面方法进行了研究。对电流强度(100-300 mA)、电解时间(10-30 min)和电极间距(1-3 cm)、概率和数学模型的影响进行了高度讨论。根据实验设计结果,实际制革废水中六价铬的去除率高达 99.58%。要达到上述效率,电流强度、时间和电极间距的最佳值分别为 211.891 mA、36.8179 min 和 1.609 cm。事实证明,电解槽操作简便,使用较便宜的电极,经济实惠,而且在处理实际制革废水时效率很高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The incorporation of activated carbon as a substrate in a constructed wetland. A review Long-term AI prediction of ammonium levels in rivers using transformer and ensemble models Groundwater salinization challenges in agriculturally valuable low-lying North Sea region: A review Sequential novel use of Moringa oleifera Lam., biochar, and sand to remove turbidity, E. coli, and heavy metals from drinking water Waste biomass-based graphene oxide decorated with ternary metal oxide (MnO-NiO-ZnO) composite for adsorption of methylene blue dye
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1