Initial Experience of Robot-Assisted Nephroureterectomy without Intraoperative Repositioning Using a New Robotic Surgical System (KD-SR-01TM).

IF 1.3 Q3 SURGERY Minimally Invasive Surgery Pub Date : 2024-08-10 eCollection Date: 2024-01-01 DOI:10.1155/2024/2466828
Jie Dong, Weifeng Xu, Zhigang Ji
{"title":"Initial Experience of Robot-Assisted Nephroureterectomy without Intraoperative Repositioning Using a New Robotic Surgical System (KD-SR-01TM).","authors":"Jie Dong, Weifeng Xu, Zhigang Ji","doi":"10.1155/2024/2466828","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Robot-assisted nephroureterectomy (RANU) has been more and more applied since 21st century. However, the high cost limits the widespread use of robot system. A relatively low-cost new robotic surgical system (KD-SR-01™) has recently been developed in China.</p><p><strong>Objective: </strong>To assess the safety and efficacy of the KD-SR-01™ Surgical System in RANU.</p><p><strong>Methods: </strong>Patients with upper-tract urothelial tumor and undergoing RANU with the KD-SR-01™ Robotic System were prospectively included. Surgeries were all performed by a single surgeon. Patients' demographic and clinical characteristics, perioperative data, pathology findings, and follow-up data were collected. <i>Key Findings</i>. 9 patients were enrolled in this study, and the surgeries went smoothly with no conversion to open. The 1<sup>st</sup> docking time, the 2<sup>nd</sup> docking time, and the operation time were 222 s, 169 s, and 202 min respectively. No equipment-related adverse events occurred. All patients were followed up for at least 3 months, and one patient experienced bladder recurrences. <i>Conclusions and Clinical Implications</i>. This study is the first to verify that the KD-SR-01™ robot system is effective and safe in RANU and has advantages in terms of its rotation boom during redocking and its price. This trial is registered with ChiCTR2200056672.</p>","PeriodicalId":45110,"journal":{"name":"Minimally Invasive Surgery","volume":"2024 ","pages":"2466828"},"PeriodicalIF":1.3000,"publicationDate":"2024-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11330330/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minimally Invasive Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/2466828","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Robot-assisted nephroureterectomy (RANU) has been more and more applied since 21st century. However, the high cost limits the widespread use of robot system. A relatively low-cost new robotic surgical system (KD-SR-01™) has recently been developed in China.

Objective: To assess the safety and efficacy of the KD-SR-01™ Surgical System in RANU.

Methods: Patients with upper-tract urothelial tumor and undergoing RANU with the KD-SR-01™ Robotic System were prospectively included. Surgeries were all performed by a single surgeon. Patients' demographic and clinical characteristics, perioperative data, pathology findings, and follow-up data were collected. Key Findings. 9 patients were enrolled in this study, and the surgeries went smoothly with no conversion to open. The 1st docking time, the 2nd docking time, and the operation time were 222 s, 169 s, and 202 min respectively. No equipment-related adverse events occurred. All patients were followed up for at least 3 months, and one patient experienced bladder recurrences. Conclusions and Clinical Implications. This study is the first to verify that the KD-SR-01™ robot system is effective and safe in RANU and has advantages in terms of its rotation boom during redocking and its price. This trial is registered with ChiCTR2200056672.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用新型机器人手术系统(KD-SR-01TM)进行无术中复位的机器人辅助肾切除术的初步经验。
背景:机器人辅助肾切除术(RANU)自 21 世纪以来得到越来越多的应用。然而,高昂的费用限制了机器人系统的广泛应用。最近,中国开发出了一种成本相对较低的新型机器人手术系统(KD-SR-01™):评估KD-SR-01™手术系统在RANU中的安全性和有效性:方法:前瞻性纳入使用 KD-SR-01™ 机器人系统进行 RANU 手术的上尿路肿瘤患者。所有手术均由一名外科医生完成。收集了患者的人口统计学和临床特征、围手术期数据、病理结果和随访数据。主要研究结果。本研究共纳入了 9 名患者,手术进展顺利,没有患者转为开腹手术。第一次对接时间、第二次对接时间和手术时间分别为 222 秒、169 秒和 202 分钟。没有发生与设备相关的不良事件。所有患者均接受了至少 3 个月的随访,其中一名患者出现了膀胱复发。结论和临床意义。本研究首次验证了 KD-SR-01™ 机器人系统在 RANU 中的有效性和安全性,并在重新对接时的旋转臂和价格方面具有优势。本试验的注册号为 ChiCTR2200056672。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.00
自引率
0.00%
发文量
8
审稿时长
16 weeks
期刊最新文献
Comparison of Mortality and Postoperative Complications Between Open and Laparoscopic Repair of Perforated Peptic Ulcer: An Umbrella Review. Initial Experience of Robot-Assisted Nephroureterectomy without Intraoperative Repositioning Using a New Robotic Surgical System (KD-SR-01TM). Comparison of Perioperative, Functional, and Oncological Outcomes of Transperitoneal and Extraperitoneal Laparoscopic Radical Prostatectomy. Laparoscopic vs. Robotic Gastrectomy in Patients with Situs Inversus Totalis: A Systematic Review. Clinical Factors to Predict Difficult Ureter during Ureteroscopic Lithotripsy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1