Daisy Guamán-Pilco, Elvira Chocano, Elena Palà, Marcel Lamana-Vallverdú, Anna Penalba, Paula García-Rodríguez, Marta Rubiera, Alejandro Bustamante, Àlex Rovira, Soledad Pérez-Sánchez, Leire Azurmendi, Sandrine Reymond, Jean-Charles Sánchez, Joan Montaner
{"title":"H-FABP as a Biomarker in Transient Ischemic Attack.","authors":"Daisy Guamán-Pilco, Elvira Chocano, Elena Palà, Marcel Lamana-Vallverdú, Anna Penalba, Paula García-Rodríguez, Marta Rubiera, Alejandro Bustamante, Àlex Rovira, Soledad Pérez-Sánchez, Leire Azurmendi, Sandrine Reymond, Jean-Charles Sánchez, Joan Montaner","doi":"10.1007/s12265-024-10552-4","DOIUrl":null,"url":null,"abstract":"<p><p>The study investigates the utility of heart fatty-acid binding protein (H-FABP) in distinguishing TIA from mimics. Data from 175 patients from the StrokeChip multicenter study was retrospectively analyzed. H-FABP level was measured using a rapid point-of-care test. Findings revealed that H-FABP levels were higher in individuals with TIA compared to mimics [3.10 ng/mL (IQR 2.13-4.78) vs. 1.70 ng/mL (IQR 1.23-2.38)] (p < 0.001). The diagnostic performance of H-FABP, assessed using the area under the curve operating characteristic curve (AUC) was 0. 83 (95% CI = 0.76-0.90) for the final model, indicating good discriminative ability. The PanelomiX determined that a combined cutoff of > 1.85 ng/ml for H-FABP, age > 42.5 years, and baseline NIHSS > 3.5 had a 100% of sensitivity and 23.30% of specificity. The study suggests that H-FABP has potential as a TIA diagnostic biomarker. The rapid application of POCT's for H-FABP measurement supports its potential use in emergency departments and primary care settings.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12265-024-10552-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
The study investigates the utility of heart fatty-acid binding protein (H-FABP) in distinguishing TIA from mimics. Data from 175 patients from the StrokeChip multicenter study was retrospectively analyzed. H-FABP level was measured using a rapid point-of-care test. Findings revealed that H-FABP levels were higher in individuals with TIA compared to mimics [3.10 ng/mL (IQR 2.13-4.78) vs. 1.70 ng/mL (IQR 1.23-2.38)] (p < 0.001). The diagnostic performance of H-FABP, assessed using the area under the curve operating characteristic curve (AUC) was 0. 83 (95% CI = 0.76-0.90) for the final model, indicating good discriminative ability. The PanelomiX determined that a combined cutoff of > 1.85 ng/ml for H-FABP, age > 42.5 years, and baseline NIHSS > 3.5 had a 100% of sensitivity and 23.30% of specificity. The study suggests that H-FABP has potential as a TIA diagnostic biomarker. The rapid application of POCT's for H-FABP measurement supports its potential use in emergency departments and primary care settings.