LNG density measurement by gravimetric method

IF 1.8 3区 工程技术 Q3 PHYSICS, APPLIED Cryogenics Pub Date : 2024-08-16 DOI:10.1016/j.cryogenics.2024.103925
Huadong Zhu , Li Zhou , Denghua He , Zixun Chen , Jintao Liu
{"title":"LNG density measurement by gravimetric method","authors":"Huadong Zhu ,&nbsp;Li Zhou ,&nbsp;Denghua He ,&nbsp;Zixun Chen ,&nbsp;Jintao Liu","doi":"10.1016/j.cryogenics.2024.103925","DOIUrl":null,"url":null,"abstract":"<div><p>Density is a critical parameter in the liquefied natural gas (LNG) industry, which necessitates the study of measurement methods. Standard methods for calculating LNG density are employed in downstream LNG custody transfer, but it still faces challenges in density measurement in the upstream, such as in LNG plants and LNG refueling station. In this paper, a gravimetric density measurement method was established for LNG plants, which is SI-traceable as it relies on volume and mass. A home-made sampling device was developed and employed to obtain the LNG volume and mass. The principle involves trapping LNG in a known-volume quantitative tube within the sampling device. The LNG is then transferred to a vacuum sampling cylinder and weighed using a mass compactor. This approach not only provides representative samples but also enables compositional analysis while performing density calculations according to ISO 6578. Feasibility and practicality tests of this novel method were conducted in an LNG plant. The test results indicate that the reproducibility is 0.6 %(RSD), and the relative expanded uncertainty is 2.0 % (<em>k</em> = 2). Compared to the revised Klosek and McKinley method (RKM), it shows a relative difference of −0.3 % to 1.5 %, demonstrating the applicability to LNG plants.</p></div>","PeriodicalId":10812,"journal":{"name":"Cryogenics","volume":"142 ","pages":"Article 103925"},"PeriodicalIF":1.8000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cryogenics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0011227524001450","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

Density is a critical parameter in the liquefied natural gas (LNG) industry, which necessitates the study of measurement methods. Standard methods for calculating LNG density are employed in downstream LNG custody transfer, but it still faces challenges in density measurement in the upstream, such as in LNG plants and LNG refueling station. In this paper, a gravimetric density measurement method was established for LNG plants, which is SI-traceable as it relies on volume and mass. A home-made sampling device was developed and employed to obtain the LNG volume and mass. The principle involves trapping LNG in a known-volume quantitative tube within the sampling device. The LNG is then transferred to a vacuum sampling cylinder and weighed using a mass compactor. This approach not only provides representative samples but also enables compositional analysis while performing density calculations according to ISO 6578. Feasibility and practicality tests of this novel method were conducted in an LNG plant. The test results indicate that the reproducibility is 0.6 %(RSD), and the relative expanded uncertainty is 2.0 % (k = 2). Compared to the revised Klosek and McKinley method (RKM), it shows a relative difference of −0.3 % to 1.5 %, demonstrating the applicability to LNG plants.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用重量法测定液化天然气密度
密度是液化天然气(LNG)行业的一个关键参数,因此有必要对测量方法进行研究。液化天然气密度的标准计算方法被应用于下游的液化天然气监管转移,但在上游的密度测量中,如液化天然气工厂和液化天然气加气站,仍然面临着挑战。本文为液化天然气工厂建立了一种重力密度测量方法,由于该方法依赖于体积和质量,因此具有 SI 可追溯性。为获得液化天然气的体积和质量,开发并使用了一种自制的采样装置。其原理是在取样装置内的已知体积定量管中捕获液化天然气。然后,将液化天然气转移到真空采样瓶中,并使用质量压缩器进行称重。这种方法不仅能提供具有代表性的样品,还能进行成分分析,同时根据 ISO 6578 标准进行密度计算。在液化天然气工厂对这种新方法进行了可行性和实用性测试。测试结果表明,重现性为 0.6%(RSD),相对扩展不确定性为 2.0%(k = 2)。与修订后的 Klosek 和 McKinley 方法 (RKM) 相比,其相对差值在 -0.3 % 到 1.5 % 之间,这表明该方法适用于液化天然气工厂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Cryogenics
Cryogenics 物理-热力学
CiteScore
3.80
自引率
9.50%
发文量
0
审稿时长
2.1 months
期刊介绍: Cryogenics is the world''s leading journal focusing on all aspects of cryoengineering and cryogenics. Papers published in Cryogenics cover a wide variety of subjects in low temperature engineering and research. Among the areas covered are: - Applications of superconductivity: magnets, electronics, devices - Superconductors and their properties - Properties of materials: metals, alloys, composites, polymers, insulations - New applications of cryogenic technology to processes, devices, machinery - Refrigeration and liquefaction technology - Thermodynamics - Fluid properties and fluid mechanics - Heat transfer - Thermometry and measurement science - Cryogenics in medicine - Cryoelectronics
期刊最新文献
Effect of carbon ion implantation on the superconducting properties of MgB2 bulks prepared by powder-in-sealed-tube method A study on the potential of cryogenic cooling and cutting technique in reducing the decommissioning cost of offshore monopiles Simulation and experimental investigation on kinetic and thermodynamic characteristics of liquid nitrogen droplets impacting superheated wall A helium isotope separation cryostat with an entropy filter cooled by a G-M cryocooler Capacitance-based mass flow rate measurement of two-phase hydrogen in a 0.5 in. tube
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1