{"title":"Prosthetic Complications of Single Screw-Retained Implant-Supported Metal-Ceramic Fixed Prostheses: A Retrospective Observational Study.","authors":"Cristina Palma-Carrió, Andrea Macconi, Andrea Rubert-Aparici, Paula Vidal-Peiró, Isabel Menéndez-Nieto, Juan Antonio Blaya-Tárraga","doi":"10.1155/2024/9242928","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze prosthetic complications of single screw-retained implant-supported metal-ceramic fixed prostheses (SSIMCFPs).</p><p><strong>Materials and methods: </strong>A total of 457 medical records of patients treated with implants at the University Dental Clinic of the European University of Valencia from 2016 to 2022 were reviewed. Of the 335 SSIMCFPs evaluated, 222 were included. The following data were collected from medical records: age, sex, prosthesis location, implant diameter, type of antagonist, date of prosthesis placement, type of prosthetic complications, and the date of the occurrence of complications. Statistical analysis was estimated at the patient level with a simple binary logistic regression and at the prosthesis level, a simple logistic regression with generalized estimating equation models (<i>p</i>  < 0.05).</p><p><strong>Results: </strong>A total of 222 SSIMCFPs were placed in 159 patients. The prevalence of complications was 23.3% at the patient level, equivalent to 21.6% of SSIMCFPs. A total of 48 complications were collected; screw loosening was the most frequent complication (16.2%), followed by ceramic fracture (3.1%), screw fracture (1.8%), and implant fracture (0.5%). There were no cases of abutment fracture. The mean time of the loosening of the screw was 10.5 months and ceramic fractures at 6.9 months. The factors that most influenced the occurrence of prosthetic complications were posterior position (<i>p</i>  < 0.001), implant diameter from 3.5 to 4.8 mm (<i>p</i>  < 0.01), and lower arch position (<i>p</i>  < 0.05).</p><p><strong>Conclusions: </strong>The most frequent complication of SSIMCFP was loosening of the screw followed by ceramic fracture. The appearance of these complications usually occurred during the first year after SSIMCFP placement. Factors related to the occurrence of complications were mandibular posterior location and implant diameter from 3.5 to 4.8 mm.</p>","PeriodicalId":13947,"journal":{"name":"International Journal of Dentistry","volume":"2024 ","pages":"9242928"},"PeriodicalIF":1.9000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11335423/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/9242928","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To analyze prosthetic complications of single screw-retained implant-supported metal-ceramic fixed prostheses (SSIMCFPs).

Materials and methods: A total of 457 medical records of patients treated with implants at the University Dental Clinic of the European University of Valencia from 2016 to 2022 were reviewed. Of the 335 SSIMCFPs evaluated, 222 were included. The following data were collected from medical records: age, sex, prosthesis location, implant diameter, type of antagonist, date of prosthesis placement, type of prosthetic complications, and the date of the occurrence of complications. Statistical analysis was estimated at the patient level with a simple binary logistic regression and at the prosthesis level, a simple logistic regression with generalized estimating equation models (p  < 0.05).

Results: A total of 222 SSIMCFPs were placed in 159 patients. The prevalence of complications was 23.3% at the patient level, equivalent to 21.6% of SSIMCFPs. A total of 48 complications were collected; screw loosening was the most frequent complication (16.2%), followed by ceramic fracture (3.1%), screw fracture (1.8%), and implant fracture (0.5%). There were no cases of abutment fracture. The mean time of the loosening of the screw was 10.5 months and ceramic fractures at 6.9 months. The factors that most influenced the occurrence of prosthetic complications were posterior position (p  < 0.001), implant diameter from 3.5 to 4.8 mm (p  < 0.01), and lower arch position (p  < 0.05).

Conclusions: The most frequent complication of SSIMCFP was loosening of the screw followed by ceramic fracture. The appearance of these complications usually occurred during the first year after SSIMCFP placement. Factors related to the occurrence of complications were mandibular posterior location and implant diameter from 3.5 to 4.8 mm.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单螺钉固位种植体支持金属陶瓷固定义齿的修复并发症:回顾性观察研究
目的:分析单螺钉固位种植体支持金属陶瓷固定修复体(SSIMCFP)的修复并发症:对巴伦西亚欧洲大学大学牙科诊所 2016 年至 2022 年期间接受种植治疗的 457 名患者的病历进行了审查。在评估的 335 例 SSIMCFP 中,有 222 例被纳入其中。从医疗记录中收集了以下数据:年龄、性别、修复体位置、种植体直径、拮抗剂类型、修复体植入日期、修复体并发症类型以及并发症发生日期。统计分析在患者层面采用简单的二元逻辑回归,在假体层面采用简单的逻辑回归和广义估计方程模型(P < 0.05):159名患者共植入了222个SSIMCFP。患者并发症发生率为 23.3%,相当于 SSIMCFP 的 21.6%。共收集到 48 例并发症;最常见的并发症是螺钉松动(16.2%),其次是陶瓷断裂(3.1%)、螺钉断裂(1.8%)和种植体断裂(0.5%)。没有基台断裂的病例。螺钉松动的平均时间为 10.5 个月,陶瓷断裂的平均时间为 6.9 个月。对修复体并发症发生影响最大的因素是后牙位(p < 0.001)、种植体直径从3.5毫米到4.8毫米(p < 0.01)以及下牙弓位置(p < 0.05):结论:SSIMCFP最常见的并发症是螺钉松动,其次是陶瓷断裂。这些并发症通常发生在植入 SSIMCFP 后的第一年。与并发症发生有关的因素包括下颌后方位置和种植体直径(3.5 至 4.8 毫米)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Dentistry
International Journal of Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
4.80%
发文量
219
审稿时长
20 weeks
期刊最新文献
Influence of Ceramic Material Type and Cement Shade on the Translucency of Lithium Disilicate Ceramic Veneers. Enhancing pH Modulation and Calcium Ions Release in External Resorption Artificial Defects: A Comparative Analysis of Ultrasonic Activation Effects on Ca(OH)2, MTA, and CEM Cement. Understanding Parental Emotions: Children's Dental Visits and the Separation Experience. Prevalence and Severity of Sleep Bruxism in Edentulous Patients: A Cross-Sectional Study. Elementary Teacher's Perception of Oral Health Education in a City of the Brazilian Amazon: A Cross-Sectional Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1