Feasibility of 3D MRI fingerprinting for rapid knee cartilage T1, T2, and T mapping at 0.55T: Comparison with 3T.

IF 2.7 4区 医学 Q2 BIOPHYSICS NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-08-21 DOI:10.1002/nbm.5250
Hector L De Moura, Anmol Monga, Xiaoxia Zhang, Marcelo V W Zibetti, Mahesh B Keerthivasan, Ravinder R Regatte
{"title":"Feasibility of 3D MRI fingerprinting for rapid knee cartilage T<sub>1</sub>, T<sub>2,</sub> and T<sub>1ρ</sub> mapping at 0.55T: Comparison with 3T.","authors":"Hector L De Moura, Anmol Monga, Xiaoxia Zhang, Marcelo V W Zibetti, Mahesh B Keerthivasan, Ravinder R Regatte","doi":"10.1002/nbm.5250","DOIUrl":null,"url":null,"abstract":"<p><p>Low-field strength scanners present an opportunity for more inclusive imaging exams and bring several challenges including lower signal-to-noise ratio (SNR) and longer scan times. Magnetic resonance fingerprinting (MRF) is a rapid quantitative multiparametric method that can enable multiple quantitative maps simultaneously. To demonstrate the feasibility of an MRF sequence for knee cartilage evaluation in a 0.55T system we performed repeatability and accuracy experiments with agar-gel phantoms. Additionally, five healthy volunteers (age 32 ± 4 years old, 2 females) were scanned at 3T and 0.55T. The MRI acquisition protocols include a stack-of-stars T<sub>1ρ</sub>-enabled MRF sequence, a VIBE sequence with variable flip angles (VFA) for T<sub>1</sub> mapping, and fat-suppressed turbo flash (TFL) sequences for T<sub>2</sub> and T<sub>1ρ</sub> mappings. Double-Echo steady-state (DESS) sequence was also used for cartilage segmentation. Acquisitions were performed at two different field strengths, 0.55T and 3T, with the same sequences but protocols were slightly different to accommodate differences in signal-to-noise ratio and relaxation times. Cartilage segmentation was done using five compartments. T<sub>1</sub>, T<sub>2</sub>, and T<sub>1ρ</sub> values were measured in the knee cartilage using both MRF and conventional relaxometry sequences. The MRF sequence demonstrated excellent repeatability in a test-retest experiment with model agar-gel phantoms, as demonstrated with correlation and Bland-Altman plots. Underestimation of T<sub>1</sub> values was observed on both field strengths, with the average global difference between reference values and the MRF being 151 ms at 0.55T and 337 ms at 3T. At 0.55T, MRF measurements presented significant biases but strong correlations with the reference measurements. Although a larger error was present in T<sub>1</sub> measurements, MRF measurements trended similarly to the conventional measurements for human subjects and model agar-gel phantoms.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5250"},"PeriodicalIF":2.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NMR in Biomedicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/nbm.5250","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Low-field strength scanners present an opportunity for more inclusive imaging exams and bring several challenges including lower signal-to-noise ratio (SNR) and longer scan times. Magnetic resonance fingerprinting (MRF) is a rapid quantitative multiparametric method that can enable multiple quantitative maps simultaneously. To demonstrate the feasibility of an MRF sequence for knee cartilage evaluation in a 0.55T system we performed repeatability and accuracy experiments with agar-gel phantoms. Additionally, five healthy volunteers (age 32 ± 4 years old, 2 females) were scanned at 3T and 0.55T. The MRI acquisition protocols include a stack-of-stars T-enabled MRF sequence, a VIBE sequence with variable flip angles (VFA) for T1 mapping, and fat-suppressed turbo flash (TFL) sequences for T2 and T mappings. Double-Echo steady-state (DESS) sequence was also used for cartilage segmentation. Acquisitions were performed at two different field strengths, 0.55T and 3T, with the same sequences but protocols were slightly different to accommodate differences in signal-to-noise ratio and relaxation times. Cartilage segmentation was done using five compartments. T1, T2, and T values were measured in the knee cartilage using both MRF and conventional relaxometry sequences. The MRF sequence demonstrated excellent repeatability in a test-retest experiment with model agar-gel phantoms, as demonstrated with correlation and Bland-Altman plots. Underestimation of T1 values was observed on both field strengths, with the average global difference between reference values and the MRF being 151 ms at 0.55T and 337 ms at 3T. At 0.55T, MRF measurements presented significant biases but strong correlations with the reference measurements. Although a larger error was present in T1 measurements, MRF measurements trended similarly to the conventional measurements for human subjects and model agar-gel phantoms.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三维磁共振成像指纹识别技术在 0.55T 下快速绘制膝关节软骨 T1、T2 和 T1ρ 图的可行性:与 3T 的比较。
低场强扫描仪为更全面的成像检查提供了机会,同时也带来了一些挑战,包括较低的信噪比(SNR)和较长的扫描时间。磁共振指纹(MRF)是一种快速定量多参数方法,可同时绘制多张定量图。为了证明在 0.55T 系统中进行膝关节软骨评估的 MRF 序列的可行性,我们使用琼脂凝胶模型进行了可重复性和准确性实验。此外,我们还在 3T 和 0.55T 扫描了五名健康志愿者(年龄 32 ± 4 岁,两名女性)。磁共振成像采集方案包括支持 T1ρ 的堆叠星 MRF 序列、用于 T1 映射的可变翻转角 (VFA) VIBE 序列以及用于 T2 和 T1ρ 映射的脂肪抑制涡轮闪光 (TFL) 序列。双回波稳态(DESS)序列也用于软骨分割。采集在两种不同的场强(0.55T 和 3T)下进行,采用相同的序列,但程序略有不同,以适应信噪比和弛豫时间的差异。软骨分割采用五个区段。使用 MRF 和传统弛豫测量序列测量了膝关节软骨的 T1、T2 和 T1ρ 值。MRF 序列在使用模型琼脂凝胶假体进行的重复测试实验中表现出极佳的可重复性,相关性和 Bland-Altman 图也证明了这一点。在两种场强下都观察到了 T1 值的低估,在 0.55T 和 3T 下,参考值和 MRF 之间的平均总体差异分别为 151 毫秒和 337 毫秒。在 0.55T 时,MRF 测量值有明显偏差,但与参考测量值有很强的相关性。虽然 T1 测量误差较大,但 MRF 测量的趋势与人体和模型琼脂凝胶假体的常规测量相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
NMR in Biomedicine
NMR in Biomedicine 医学-光谱学
CiteScore
6.00
自引率
10.30%
发文量
209
审稿时长
3-8 weeks
期刊介绍: NMR in Biomedicine is a journal devoted to the publication of original full-length papers, rapid communications and review articles describing the development of magnetic resonance spectroscopy or imaging methods or their use to investigate physiological, biochemical, biophysical or medical problems. Topics for submitted papers should be in one of the following general categories: (a) development of methods and instrumentation for MR of biological systems; (b) studies of normal or diseased organs, tissues or cells; (c) diagnosis or treatment of disease. Reports may cover work on patients or healthy human subjects, in vivo animal experiments, studies of isolated organs or cultured cells, analysis of tissue extracts, NMR theory, experimental techniques, or instrumentation.
期刊最新文献
The effect of fat model variation on muscle fat fraction quantification in a cross-sectional cohort. Improvement of MRS at ultra-high field using a wireless RF array. Very-long T2-weighted imaging of the non-lesional brain tissue in multiple sclerosis patients. Simultaneous whole-liver water T 1 and T 2 mapping with isotropic resolution during free-breathing. Automatic pipeline for segmentation of LV myocardium on quantitative MR T1 maps using deep learning model and computation of radial T1 and ECV values.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1