Keith A Corl, Mitchell M Levy, Andre L Holder, Ivor S Douglas, Walter T Linde-Zwirble, Aftab Alam
{"title":"Moderate IV Fluid Resuscitation Is Associated With Decreased Sepsis Mortality.","authors":"Keith A Corl, Mitchell M Levy, Andre L Holder, Ivor S Douglas, Walter T Linde-Zwirble, Aftab Alam","doi":"10.1097/CCM.0000000000006394","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Significant practice variation exists in the amount of resuscitative IV fluid given to patients with sepsis. Current research suggests equipoise between a tightly restrictive or more liberal strategy but data is lacking on a wider range of resuscitation practices. We sought to examine the relationship between a wide range of fluid resuscitation practices and sepsis mortality and then identify the primary driver of this practice variation.</p><p><strong>Design: </strong>Retrospective analysis of the Premier Healthcare Database.</p><p><strong>Setting: </strong>Six hundred twelve U.S. hospitals.</p><p><strong>Patients: </strong>Patients with sepsis and septic shock admitted from the emergency department to the ICU from January 1, 2016, to December 31, 2019.</p><p><strong>Interventions: </strong>The volume of resuscitative IV fluid administered before the end of hospital day- 1 and mortality.</p><p><strong>Measurements and main results: </strong>In total, 190,682 patients with sepsis and septic shock were included in the analysis. Based upon patient characteristics and illness severity, we predicted that physicians should prescribe patients with sepsis a narrow mean range of IV fluid (95% range, 3.6-4.5 L). Instead, we observed wide variation in the mean IV fluids administered (95% range, 1.7-7.4 L). After splitting the patients into five groups based upon attending physician practice, we observed patients in the moderate group (4.0 L; interquartile range [IQR], 2.4-5.1 L) experienced a 2.5% reduction in risk-adjusted mortality compared with either the very low (1.6 L; IQR, 1.0-2.5 L) or very high (6.1 L; IQR, 4.0-9.0 L) fluid groups p < 0.01). An analysis of within- and between-hospital IV fluid resuscitation practices showed that physician variation within hospitals instead of practice differences between hospitals accounts for the observed variation.</p><p><strong>Conclusions: </strong>Individual physician practice drives excess variation in the amount of IV fluid given to patients with sepsis. A moderate approach to IV fluid resuscitation is associated with decreased sepsis mortality and should be tested in future randomized controlled trials.</p>","PeriodicalId":10765,"journal":{"name":"Critical Care Medicine","volume":" ","pages":"e557-e567"},"PeriodicalIF":7.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11469629/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical Care Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/CCM.0000000000006394","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/23 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Significant practice variation exists in the amount of resuscitative IV fluid given to patients with sepsis. Current research suggests equipoise between a tightly restrictive or more liberal strategy but data is lacking on a wider range of resuscitation practices. We sought to examine the relationship between a wide range of fluid resuscitation practices and sepsis mortality and then identify the primary driver of this practice variation.
Design: Retrospective analysis of the Premier Healthcare Database.
Setting: Six hundred twelve U.S. hospitals.
Patients: Patients with sepsis and septic shock admitted from the emergency department to the ICU from January 1, 2016, to December 31, 2019.
Interventions: The volume of resuscitative IV fluid administered before the end of hospital day- 1 and mortality.
Measurements and main results: In total, 190,682 patients with sepsis and septic shock were included in the analysis. Based upon patient characteristics and illness severity, we predicted that physicians should prescribe patients with sepsis a narrow mean range of IV fluid (95% range, 3.6-4.5 L). Instead, we observed wide variation in the mean IV fluids administered (95% range, 1.7-7.4 L). After splitting the patients into five groups based upon attending physician practice, we observed patients in the moderate group (4.0 L; interquartile range [IQR], 2.4-5.1 L) experienced a 2.5% reduction in risk-adjusted mortality compared with either the very low (1.6 L; IQR, 1.0-2.5 L) or very high (6.1 L; IQR, 4.0-9.0 L) fluid groups p < 0.01). An analysis of within- and between-hospital IV fluid resuscitation practices showed that physician variation within hospitals instead of practice differences between hospitals accounts for the observed variation.
Conclusions: Individual physician practice drives excess variation in the amount of IV fluid given to patients with sepsis. A moderate approach to IV fluid resuscitation is associated with decreased sepsis mortality and should be tested in future randomized controlled trials.
期刊介绍:
Critical Care Medicine is the premier peer-reviewed, scientific publication in critical care medicine. Directed to those specialists who treat patients in the ICU and CCU, including chest physicians, surgeons, pediatricians, pharmacists/pharmacologists, anesthesiologists, critical care nurses, and other healthcare professionals, Critical Care Medicine covers all aspects of acute and emergency care for the critically ill or injured patient.
Each issue presents critical care practitioners with clinical breakthroughs that lead to better patient care, the latest news on promising research, and advances in equipment and techniques.