[Effectiveness comparison of robot-assisted and traditional freehand technology in treatment of atlantoaxial dislocation].

Haiping Zhang, Dingjun Hao, Baorong He, Zhengwei Xu, Yongchao Duan, Wenlong Yang, Houkun Li, Changjiang Kou, Ke Wang
{"title":"[Effectiveness comparison of robot-assisted and traditional freehand technology in treatment of atlantoaxial dislocation].","authors":"Haiping Zhang, Dingjun Hao, Baorong He, Zhengwei Xu, Yongchao Duan, Wenlong Yang, Houkun Li, Changjiang Kou, Ke Wang","doi":"10.7507/1002-1892.202405006","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the effectiveness of robot-assisted and traditional freehand screw placement in the treatment of atlantoaxial dislocation.</p><p><strong>Methods: </strong>The clinical data of 55 patients with atlantoaxial dislocation who met the selection criteria between January 2021 and January 2024 were retrospectively analyzed. According to different screw placement methods, they were divided into the traditional group (using the traditional freedhand screw placement, 31 cases) and the robot group (using the Mazor X robot-assisted screw placement, 24 cases). There was no significant difference in gender, age, body mass index, etiology, and preoperative visual analogue scale (VAS) score, cervical spine Japanese Orthopaedic Association (JOA) score between the two groups ( <i>P</i>>0.05). The operation time, intraoperative blood loss, operation cost, and intraoperative complications were recorded and compared between the two groups. The VAS score and cervical spine JOA score were used to evaluate the improvement of pain and cervical spinal cord function before operation and at 1 month after operation. CT examination was performed at 3 days after operation, and the accuracy of screw placement was evaluated according to Neo grading criteria.</p><p><strong>Results: </strong>All the 55 patients successfully completed the operation. The operation time, intraoperative blood loss, and operation cost in the robot group were significantly higher than those in the traditional group ( <i>P</i><0.05). A total of 220 C <sub>1</sub> and C <sub>2</sub> pedicle screws were inserted in the two groups, and 94 were inserted in the robot group, with an accuracy rate of 95.7%, among them, 2 were inserted by traditional freehand screw placement due to bleeding caused by intraoperative slip. And 126 pedicle screws were inserted in the traditional group, with an accuracy rate of 87.3%, which was significantly lower than that in the robot group ( <i>P</i><0.05). There were 1 case of venous plexus injury in the robot group and 3 cases in the traditional group, which improved after pressure hemostasis treatment. No other intraoperative complication such as vertebral artery injury or spinal cord injury occurred in both groups. All patients were followed up 4-16 months with an average of 6.6 months, and there was no significant difference in the follow-up time between the two groups ( <i>P</i>>0.05). Postoperative neck pain significantly relieved in both groups, and neurological symptoms relieved to varying degrees. The VAS score and cervicle spine JOA score of both groups significantly improved at 1 month after operation when compared with preoperative scores ( <i>P</i><0.05), and there was no significant difference in the score change between the two groups ( <i>P</i>>0.05).</p><p><strong>Conclusion: </strong>In the treatment of atlantoaxial dislocation, the accuracy of robot-assisted screw placement is superior to the traditional freedhand screw placement.</p>","PeriodicalId":23979,"journal":{"name":"中国修复重建外科杂志","volume":"38 8","pages":"917-922"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11335588/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国修复重建外科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7507/1002-1892.202405006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare the effectiveness of robot-assisted and traditional freehand screw placement in the treatment of atlantoaxial dislocation.

Methods: The clinical data of 55 patients with atlantoaxial dislocation who met the selection criteria between January 2021 and January 2024 were retrospectively analyzed. According to different screw placement methods, they were divided into the traditional group (using the traditional freedhand screw placement, 31 cases) and the robot group (using the Mazor X robot-assisted screw placement, 24 cases). There was no significant difference in gender, age, body mass index, etiology, and preoperative visual analogue scale (VAS) score, cervical spine Japanese Orthopaedic Association (JOA) score between the two groups ( P>0.05). The operation time, intraoperative blood loss, operation cost, and intraoperative complications were recorded and compared between the two groups. The VAS score and cervical spine JOA score were used to evaluate the improvement of pain and cervical spinal cord function before operation and at 1 month after operation. CT examination was performed at 3 days after operation, and the accuracy of screw placement was evaluated according to Neo grading criteria.

Results: All the 55 patients successfully completed the operation. The operation time, intraoperative blood loss, and operation cost in the robot group were significantly higher than those in the traditional group ( P<0.05). A total of 220 C 1 and C 2 pedicle screws were inserted in the two groups, and 94 were inserted in the robot group, with an accuracy rate of 95.7%, among them, 2 were inserted by traditional freehand screw placement due to bleeding caused by intraoperative slip. And 126 pedicle screws were inserted in the traditional group, with an accuracy rate of 87.3%, which was significantly lower than that in the robot group ( P<0.05). There were 1 case of venous plexus injury in the robot group and 3 cases in the traditional group, which improved after pressure hemostasis treatment. No other intraoperative complication such as vertebral artery injury or spinal cord injury occurred in both groups. All patients were followed up 4-16 months with an average of 6.6 months, and there was no significant difference in the follow-up time between the two groups ( P>0.05). Postoperative neck pain significantly relieved in both groups, and neurological symptoms relieved to varying degrees. The VAS score and cervicle spine JOA score of both groups significantly improved at 1 month after operation when compared with preoperative scores ( P<0.05), and there was no significant difference in the score change between the two groups ( P>0.05).

Conclusion: In the treatment of atlantoaxial dislocation, the accuracy of robot-assisted screw placement is superior to the traditional freedhand screw placement.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[机器人辅助与传统徒手技术治疗寰枢椎脱位的疗效比较]。
目的:比较机器人辅助和传统徒手螺钉置入治疗寰枢椎脱位的效果:比较机器人辅助和传统徒手螺钉置入治疗寰枢椎脱位的效果:回顾性分析 2021 年 1 月至 2024 年 1 月期间符合入选标准的 55 例寰枢关节脱位患者的临床资料。根据螺钉置入方法的不同,将其分为传统组(使用传统自由手螺钉置入,31 例)和机器人组(使用 Mazor X 机器人辅助螺钉置入,24 例)。两组患者在性别、年龄、体重指数、病因、术前视觉模拟量表(VAS)评分、颈椎日本骨科协会(JOA)评分等方面均无明显差异(P>0.05)。记录并比较了两组患者的手术时间、术中失血量、手术费用和术中并发症。采用 VAS 评分和颈椎 JOA 评分来评估术前和术后 1 个月疼痛和颈脊髓功能的改善情况。术后 3 天进行 CT 检查,并根据 Neo 分级标准评估螺钉置入的准确性:结果:55 例患者均顺利完成手术。结果:55 例患者均顺利完成手术,机器人组的手术时间、术中失血量和手术费用明显高于传统组(两组患者均植入 P1 和 C 2 椎弓根螺钉,机器人组植入 94 颗,准确率 95.7%,其中 2 颗因术中滑脱导致出血而采用传统徒手螺钉置入。传统组植入椎弓根螺钉126枚,准确率为87.3%,明显低于机器人组(PP>0.05)。两组患者术后颈部疼痛均明显缓解,神经症状也有不同程度的缓解。两组患者术后1个月的VAS评分和颈椎JOA评分均较术前明显改善(PP>0.05):结论:在寰枢脱位的治疗中,机器人辅助螺钉置入术的准确性优于传统的徒手螺钉置入术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中国修复重建外科杂志
中国修复重建外科杂志 Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
11334
期刊介绍:
期刊最新文献
[Anatomical research of positional relationship between protective channel and sural nerve during Achilles tendon repair using channel assisted minimally invasive repair technique]. [Application and progress of bio-derived materials in bladder regeneration and repair]. [Clinical diagnostic study of Ramp lesion of medial meniscus based on knee MRI at 90° flexed position]. [Clinical study of percutaneous endoscopic thoracic spine surgery via trench technique for thoracic spinal cord ventral decompression]. [Early effectiveness of unilateral biportal endoscopy technique for migrated lumbar intervertebral disc herniation].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1