{"title":"Assessment of ganglion cell complex thickness and its correlation with retinal sensitivity using microperimetry 6 months after epiretinal membrane surgery.","authors":"Leonardo Provetti Cunha, Aline Mota Freitas Matos, Raphael Lucas Sampaio Defina, Luciana Virgínia Ferreira Costa-Cunha, Leandro Cabral Zacharias, Rony Carlos Preti, Mário Luiz Ribeiro Monteiro","doi":"10.1186/s40942-024-00576-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To verify the correlation between the full-macular and the ganglion cell complex (GCC) thickness measurements and retinal sensitivity (RS) assessed by microperimetry (MP) 6 months after surgical peeling for idiopathic epiretinal membrane (ERM).</p><p><strong>Methods: </strong>Forty-three were submitted to pars-plana posterior vitrectomy (PPV) with concomitant peeling of internal limiting membrane (ILM) for idiopathic ERM treatment. Best-corrected visual acuity (BCVA) and 3D volumetric high-definition optical coherence tomography (OCT) imaging were preoperatively acquired. Six months after the surgery, BCVA, OCT imaging, and RS measured by MP were assessed. For the OCT parameters, we analyzed both the full-macular and the ganglion cell layer complex (GCC) thicknesses. The MP parameters tested were 44 points covering 20 central degrees (6 mm), with direct correspondence with the nine sectors of the OCT-ETDRS map. This approach enables the direct topographic correlation between the structure and functional measurements. The OCT and MP exam measurements were also performed in 43 eyes of age-matched healthy controls. Correlations between BCVA, RS, and OCT parameters were examined.</p><p><strong>Results: </strong> All patients exhibited a substantial improvement in visual acuity following surgery. The RS parameters were significantly lower in patients compared to the controls. The full-macular thickness measurements were thicker than controls preoperatively and significantly reduced postoperatively; however, remaining significantly higher than controls, in the 4 inner sectors, at the fovea and for the average macular thickness. Preoperative GCC measurements were higher than those in controls. There was a significant reduction in GCC thickness in all sectors postoperatively, especially in the outer sectors, as well as in the average macular thickness. A positive correlation was found between full-macular and GCC thickness and RS postoperatively in several sectors.</p><p><strong>Conclusions: </strong>Our results demonstrate that ERM peeling can improve visual acuity in the postoperative period. However, RS may not fully restore, remaining significantly lower when compared to the controls. Both full-macular and GCC thickness measurements were reduced 6 months after surgery. However, significant thinning of the GCC thickness was observed when compared to the normal control eyes, indicating the occurrence of some degree of ganglion cell layer atrophy. We have demonstrated significant correlations among various OCT thickness parameters, particularly for GCC measurements. We believe that GCC integrity may play an important role in visual function after ERM surgery, and that MP may help better understand the correlations between structural and functional findings following ERM surgery.</p>","PeriodicalId":14289,"journal":{"name":"International Journal of Retina and Vitreous","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11344420/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Retina and Vitreous","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40942-024-00576-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To verify the correlation between the full-macular and the ganglion cell complex (GCC) thickness measurements and retinal sensitivity (RS) assessed by microperimetry (MP) 6 months after surgical peeling for idiopathic epiretinal membrane (ERM).

Methods: Forty-three were submitted to pars-plana posterior vitrectomy (PPV) with concomitant peeling of internal limiting membrane (ILM) for idiopathic ERM treatment. Best-corrected visual acuity (BCVA) and 3D volumetric high-definition optical coherence tomography (OCT) imaging were preoperatively acquired. Six months after the surgery, BCVA, OCT imaging, and RS measured by MP were assessed. For the OCT parameters, we analyzed both the full-macular and the ganglion cell layer complex (GCC) thicknesses. The MP parameters tested were 44 points covering 20 central degrees (6 mm), with direct correspondence with the nine sectors of the OCT-ETDRS map. This approach enables the direct topographic correlation between the structure and functional measurements. The OCT and MP exam measurements were also performed in 43 eyes of age-matched healthy controls. Correlations between BCVA, RS, and OCT parameters were examined.

Results:  All patients exhibited a substantial improvement in visual acuity following surgery. The RS parameters were significantly lower in patients compared to the controls. The full-macular thickness measurements were thicker than controls preoperatively and significantly reduced postoperatively; however, remaining significantly higher than controls, in the 4 inner sectors, at the fovea and for the average macular thickness. Preoperative GCC measurements were higher than those in controls. There was a significant reduction in GCC thickness in all sectors postoperatively, especially in the outer sectors, as well as in the average macular thickness. A positive correlation was found between full-macular and GCC thickness and RS postoperatively in several sectors.

Conclusions: Our results demonstrate that ERM peeling can improve visual acuity in the postoperative period. However, RS may not fully restore, remaining significantly lower when compared to the controls. Both full-macular and GCC thickness measurements were reduced 6 months after surgery. However, significant thinning of the GCC thickness was observed when compared to the normal control eyes, indicating the occurrence of some degree of ganglion cell layer atrophy. We have demonstrated significant correlations among various OCT thickness parameters, particularly for GCC measurements. We believe that GCC integrity may play an important role in visual function after ERM surgery, and that MP may help better understand the correlations between structural and functional findings following ERM surgery.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用显微视力计评估视网膜外膜手术 6 个月后神经节细胞复合体的厚度及其与视网膜灵敏度的相关性。
目的:验证特发性视网膜外膜(ERM)手术剥离6个月后全玻璃体和神经节细胞复合体(GCC)厚度测量值与显微视力计(MP)评估的视网膜灵敏度(RS)之间的相关性:方法:43 例特发性视网膜外膜(ERM)患者接受了副板后玻璃体切除术(PPV),并同时进行了内层限局膜(ILM)剥离术。术前采集了最佳矫正视力(BCVA)和三维容积高清光学相干断层扫描(OCT)成像。术后六个月,对最佳矫正视力(BCVA)、OCT 成像和 MP 测量的 RS 进行评估。对于 OCT 参数,我们分析了全黄斑和神经节细胞层复合体(GCC)的厚度。测试的 MP 参数为 44 个点,覆盖 20 个中心度(6 毫米),与 OCT-ETDRS 地图的 9 个扇区直接对应。这种方法可实现结构和功能测量之间的直接地形关联。此外,还对 43 名年龄匹配的健康对照者的眼睛进行了 OCT 和 MP 检查测量。对 BCVA、RS 和 OCT 参数之间的相关性进行了研究: 结果:所有患者术后视力均有显著改善。与对照组相比,患者的 RS 参数明显降低。全黄斑厚度测量值在术前比对照组厚,术后明显降低;但在4个内区、眼窝和平均黄斑厚度方面,仍明显高于对照组。术前的 GCC 测量值高于对照组。术后所有区段的 GCC 厚度都明显减少,尤其是外侧区段和黄斑平均厚度。在几个区段,术后全黄斑和 GCC 厚度与 RS 之间呈正相关:我们的研究结果表明,ERM 剥脱术可以提高术后视力。结论:我们的研究结果表明,ERM 剥脱术可提高术后视力,但 RS 可能无法完全恢复,与对照组相比仍明显较低。术后 6 个月,全玻璃体和 GCC 厚度测量值均有所下降。然而,与正常对照组相比,我们观察到 GCC 厚度明显变薄,这表明神经节细胞层出现了一定程度的萎缩。我们已经证明了各种 OCT 厚度参数之间的显著相关性,尤其是 GCC 测量值。我们认为,GCC 的完整性可能在 ERM 手术后的视觉功能中发挥重要作用,而 MP 可能有助于更好地理解 ERM 手术后结构和功能结果之间的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
4.30%
发文量
81
审稿时长
19 weeks
期刊介绍: International Journal of Retina and Vitreous focuses on the ophthalmic subspecialty of vitreoretinal disorders. The journal presents original articles on new approaches to diagnosis, outcomes of clinical trials, innovations in pharmacological therapy and surgical techniques, as well as basic science advances that impact clinical practice. Topical areas include, but are not limited to: -Imaging of the retina, choroid and vitreous -Innovations in optical coherence tomography (OCT) -Small-gauge vitrectomy, retinal detachment, chromovitrectomy -Electroretinography (ERG), microperimetry, other functional tests -Intraocular tumors -Retinal pharmacotherapy & drug delivery -Diabetic retinopathy & other vascular diseases -Age-related macular degeneration (AMD) & other macular entities
期刊最新文献
Intravitreal faricimab for treatment naïve patients with neovascular age-related macular degeneration: a real-world prospective study. Retinal vascular changes after Silicon Oil removal in the Eye with Rhegmatogenous Retinal detachment. Short pulse grid and subthreshold micropulse laser (the sandwich grid) plus intravitreal ranibizumab for the treatment of diabetic macular edema. The digital age in retinal practice. Retrolental cohesive ophthalmic viscoelastic injection for severe subluxated cataracts: a prospective study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1