Identifying the optimal measurement timing and hemodynamic targets of portal pressure gradient after TIPS in patients with cirrhosis and variceal bleeding.
Yong Lv, Qiuhe Wang, Bohan Luo, Wei Bai, Menghao Li, Kai Li, Zhengyu Wang, Dongdong Xia, Wengang Guo, Xiaomei Li, Jie Yuan, Na Zhang, Xing Wang, Huahong Xie, Yanglin Pan, Yongzhan Nie, Zhanxin Yin, Daiming Fan, Guohong Han
{"title":"Identifying the optimal measurement timing and hemodynamic targets of portal pressure gradient after TIPS in patients with cirrhosis and variceal bleeding.","authors":"Yong Lv, Qiuhe Wang, Bohan Luo, Wei Bai, Menghao Li, Kai Li, Zhengyu Wang, Dongdong Xia, Wengang Guo, Xiaomei Li, Jie Yuan, Na Zhang, Xing Wang, Huahong Xie, Yanglin Pan, Yongzhan Nie, Zhanxin Yin, Daiming Fan, Guohong Han","doi":"10.1016/j.jhep.2024.08.007","DOIUrl":null,"url":null,"abstract":"<p><strong>Background & aims: </strong>The optimal timing of measurement and hemodynamic targets of portacaval pressure gradient (PPG) after transjugular intrahepatic portosystemic shunt (TIPS) placement remain unclear. This study aimed to identify the ideal moment for hemodynamic measurements and the optimal target of PPG in patients undergoing covered TIPS for variceal bleeding.</p><p><strong>Methods: </strong>Between May 2018 and December 2021, 466 consecutive patients with recurrent variceal bleeding treated with covered TIPS were prospectively included. Post-TIPS PPG was measured immediately (immediate PPG), 24-72 hours (early PPG), and again 1 month (late PPG) after TIPS placement. The agreement among PPGs measured at different time points was assessed by intra-class correlation coefficient (ICC) and Bland-Altman method. The unadjusted and confounder-adjusted effects of PPGs on clinical outcomes (portal hypertensive complications [PHCs], overt hepatic encephalopathy [OHE], further decompensation, and death) were assessed using Fine and Gray competing risk regression models.</p><p><strong>Results: </strong>The agreement between early PPG and late PPG (ICC: 0.34) was better than that between immediate PPG and late PPG (ICC: 0.23, p <0.001). Early PPG revealed an excellent predictive value for PHCs (early PPG≥ vs. <12 mmHg: adjusted hazard ratio 2.17, 95% CI 1.33-3.55, p = 0.002) and OHE (0.40, 95% CI 0.17-0.91, p = 0.030), while immediate PPG did not. Late PPG showed a predictive value for PHC risk but not OHE. By targeting the lowest risk of further decompensation, we identified an optimal hemodynamic target with early PPG ranging from 11 to 14 mmHg that was associated with a decreased risk of OHE and effective prevention of PHC.</p><p><strong>Conclusions: </strong>PPG measured 24 to 72 hours after TIPS correlates with long-term PPG and clinical outcomes, and a hemodynamic target PPG of 11-14 mmHg is associated with reduced encephalopathy but not compromised clinical efficacy.</p><p><strong>Impact and implications: </strong>The optimal timing of measurement and hemodynamic targets of portacaval pressure gradient (PPG) after transjugular intrahepatic portosystemic shunt (TIPS) remain unclear. Here we show that post-TIPS PPG measured at least 24 hours but not immediately after the procedure correlated with long-term PPG and clinical events. Thus, PPG measurements taken at least 24 hours after TIPS should be used to guide decision making in order to improve clinical outcomes. Targeting a post-TIPS PPG of 11-14 mmHg or a 20%-50% relative reduction from pre-TIPS baseline measured 24-72 hours after the procedure was associated with reduced encephalopathy but not compromised clinical efficacy. Thus, these criteria could be used to guide TIPS creation and revision in patients with cirrhosis and variceal bleeding undergoing covered TIPS.</p><p><strong>Clinical trial registration number: </strong>ClinicalTrials.gov, ID: NCT03590288.</p>","PeriodicalId":15888,"journal":{"name":"Journal of Hepatology","volume":null,"pages":null},"PeriodicalIF":26.8000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hepatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jhep.2024.08.007","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background & aims: The optimal timing of measurement and hemodynamic targets of portacaval pressure gradient (PPG) after transjugular intrahepatic portosystemic shunt (TIPS) placement remain unclear. This study aimed to identify the ideal moment for hemodynamic measurements and the optimal target of PPG in patients undergoing covered TIPS for variceal bleeding.
Methods: Between May 2018 and December 2021, 466 consecutive patients with recurrent variceal bleeding treated with covered TIPS were prospectively included. Post-TIPS PPG was measured immediately (immediate PPG), 24-72 hours (early PPG), and again 1 month (late PPG) after TIPS placement. The agreement among PPGs measured at different time points was assessed by intra-class correlation coefficient (ICC) and Bland-Altman method. The unadjusted and confounder-adjusted effects of PPGs on clinical outcomes (portal hypertensive complications [PHCs], overt hepatic encephalopathy [OHE], further decompensation, and death) were assessed using Fine and Gray competing risk regression models.
Results: The agreement between early PPG and late PPG (ICC: 0.34) was better than that between immediate PPG and late PPG (ICC: 0.23, p <0.001). Early PPG revealed an excellent predictive value for PHCs (early PPG≥ vs. <12 mmHg: adjusted hazard ratio 2.17, 95% CI 1.33-3.55, p = 0.002) and OHE (0.40, 95% CI 0.17-0.91, p = 0.030), while immediate PPG did not. Late PPG showed a predictive value for PHC risk but not OHE. By targeting the lowest risk of further decompensation, we identified an optimal hemodynamic target with early PPG ranging from 11 to 14 mmHg that was associated with a decreased risk of OHE and effective prevention of PHC.
Conclusions: PPG measured 24 to 72 hours after TIPS correlates with long-term PPG and clinical outcomes, and a hemodynamic target PPG of 11-14 mmHg is associated with reduced encephalopathy but not compromised clinical efficacy.
Impact and implications: The optimal timing of measurement and hemodynamic targets of portacaval pressure gradient (PPG) after transjugular intrahepatic portosystemic shunt (TIPS) remain unclear. Here we show that post-TIPS PPG measured at least 24 hours but not immediately after the procedure correlated with long-term PPG and clinical events. Thus, PPG measurements taken at least 24 hours after TIPS should be used to guide decision making in order to improve clinical outcomes. Targeting a post-TIPS PPG of 11-14 mmHg or a 20%-50% relative reduction from pre-TIPS baseline measured 24-72 hours after the procedure was associated with reduced encephalopathy but not compromised clinical efficacy. Thus, these criteria could be used to guide TIPS creation and revision in patients with cirrhosis and variceal bleeding undergoing covered TIPS.
期刊介绍:
The Journal of Hepatology is the official publication of the European Association for the Study of the Liver (EASL). It is dedicated to presenting clinical and basic research in the field of hepatology through original papers, reviews, case reports, and letters to the Editor. The Journal is published in English and may consider supplements that pass an editorial review.