Enhanced Outcomes and Safety of Reverse Shoulder Arthroplasty in Rotator Cuff Deficiency and Proximal Humerus Fractures: A 22-Patient Retrospective Analysis.
{"title":"Enhanced Outcomes and Safety of Reverse Shoulder Arthroplasty in Rotator Cuff Deficiency and Proximal Humerus Fractures: A 22-Patient Retrospective Analysis.","authors":"Yılmaz Tutak, Bilal Gök","doi":"10.12659/MSM.945241","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND Reverse shoulder arthroplasty (RSA) is an accepted treatment that provides reproducible results in the treatment of rotator cuff deficiency and proximal humerus fractures. This single-center study aimed to evaluate the outcomes from reverse shoulder arthroplasty for rotator cuff ınsufficiency and proximal humerus fractures in 22 patients from a single center. MATERIAL AND METHODS Twenty-two patients were included in the study. The median age of the patients was 66 years (Range: 58-95). Proximal humerus fractures were diagnosed using X-ray and CT, while rotator cuff tears were diagnosed using MRI. For the assessment of joint function, the Constant-Murley score, the American Shoulder and Elbow Surgeons (ASES), and the Disabilities of Arm, Shoulder, and Hand (DASH) scores were used as patient-reported outcome measures. Kaplan-Meier analysis was conducted to evaluate implant survival. RESULTS The mean follow-up duration was 4.05±1.2 years. Significant improvements were observed: ASES Score: Increased from 35.8±2.8 to 81.3±5.4 (p<0.001). VAS Pain Score: Decreased from 7.3±1 to 2.9±0.9 (p<0.001). DASH Score: Improved from 66.3±4.3 to 32.5±3.6 (p<0.001). Constant-Murley Score: Increased from 48.3±3.5 to 74.6±7.7 (p<0.001). Kaplan-Meier analysis estimated implant survival at 6.7 years (95% CI, 6.3-7.2). CONCLUSIONS When performed with appropriate indications, RSA yields positive results, as seen in the literature and our study. Interscalene block anesthesia, advancements in implant technology, and adherence to surgical procedures can reduce RSA complications and ensure its safe application.</p>","PeriodicalId":48888,"journal":{"name":"Medical Science Monitor","volume":"30 ","pages":"e945241"},"PeriodicalIF":3.1000,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11360653/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Science Monitor","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12659/MSM.945241","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) is an accepted treatment that provides reproducible results in the treatment of rotator cuff deficiency and proximal humerus fractures. This single-center study aimed to evaluate the outcomes from reverse shoulder arthroplasty for rotator cuff ınsufficiency and proximal humerus fractures in 22 patients from a single center. MATERIAL AND METHODS Twenty-two patients were included in the study. The median age of the patients was 66 years (Range: 58-95). Proximal humerus fractures were diagnosed using X-ray and CT, while rotator cuff tears were diagnosed using MRI. For the assessment of joint function, the Constant-Murley score, the American Shoulder and Elbow Surgeons (ASES), and the Disabilities of Arm, Shoulder, and Hand (DASH) scores were used as patient-reported outcome measures. Kaplan-Meier analysis was conducted to evaluate implant survival. RESULTS The mean follow-up duration was 4.05±1.2 years. Significant improvements were observed: ASES Score: Increased from 35.8±2.8 to 81.3±5.4 (p<0.001). VAS Pain Score: Decreased from 7.3±1 to 2.9±0.9 (p<0.001). DASH Score: Improved from 66.3±4.3 to 32.5±3.6 (p<0.001). Constant-Murley Score: Increased from 48.3±3.5 to 74.6±7.7 (p<0.001). Kaplan-Meier analysis estimated implant survival at 6.7 years (95% CI, 6.3-7.2). CONCLUSIONS When performed with appropriate indications, RSA yields positive results, as seen in the literature and our study. Interscalene block anesthesia, advancements in implant technology, and adherence to surgical procedures can reduce RSA complications and ensure its safe application.
期刊介绍:
Medical Science Monitor (MSM) established in 1995 is an international, peer-reviewed scientific journal which publishes original articles in Clinical Medicine and related disciplines such as Epidemiology and Population Studies, Product Investigations, Development of Laboratory Techniques :: Diagnostics and Medical Technology which enable presentation of research or review works in overlapping areas of medicine and technology such us (but not limited to): medical diagnostics, medical imaging systems, computer simulation of health and disease processes, new medical devices, etc. Reviews and Special Reports - papers may be accepted on the basis that they provide a systematic, critical and up-to-date overview of literature pertaining to research or clinical topics. Meta-analyses are considered as reviews. A special attention will be paid to a teaching value of a review paper.
Medical Science Monitor is internationally indexed in Thomson-Reuters Web of Science, Journals Citation Report (JCR), Science Citation Index Expanded (SCI), Index Medicus MEDLINE, PubMed, PMC, EMBASE/Excerpta Medica, Chemical Abstracts CAS and Index Copernicus.