Outcomes of the Victo™ adjustable artificial urinary sphincter in the treatment of male incontinence.

IF 3.7 2区 医学 Q1 UROLOGY & NEPHROLOGY BJU International Pub Date : 2024-08-26 DOI:10.1111/bju.16511
Jan Krhut, Lucie Bartáková, Adéla Kondé, Radek Paus Sýkora, Tomáš Rychlý, Roman Zachoval
{"title":"Outcomes of the Victo™ adjustable artificial urinary sphincter in the treatment of male incontinence.","authors":"Jan Krhut, Lucie Bartáková, Adéla Kondé, Radek Paus Sýkora, Tomáš Rychlý, Roman Zachoval","doi":"10.1111/bju.16511","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To report the clinical outcomes of the Victo™ (Promedon, Cordoba, Argentina) adjustable artificial urinary sphincter (AUS) implantation in a cohort of patients with severe urinary incontinence (UI) after prostate surgery.</p><p><strong>Patients and methods: </strong>This study enrolled patients with UI following prostate surgery who underwent a Victo implantation between May 2018 and December 2023. Patients were prospectively evaluated at baseline, and at 3 and 12 months after device activation, and thereafter annually. The 24-h pad-weight test (24hPWT) was used to assess severity of UI, while the Patient Global Impression of Improvement (PGI-I) and patient satisfaction according to a Likert scale were used to measure patient-reported outcomes.</p><p><strong>Results: </strong>A total of 96 patients with a median (interquartile range [IQR]) age of 68 (65-72) years were included in the final analysis. The median (IQR) follow-up was 3 (1-4) years. In all, 10 patients completed the 5-year follow-up. After the treatment, we observed a significant reduction in 24hPWT by the median of 83% (P < 0.001) at 3 months and by a median of 79% (P < 0.001) at 3 years. According to the PGI-I, a total of 87%, 92%, 87%, 81%, 83%, and 50% (five of 10) of patients rated their condition/incontinence as 'very much improved', 'much improved' or 'little improved' at 3 months, 1-, 2-, 3-, 4-, and 5-year follow-up visits, respectively. The proportion of patients, who were 'very satisfied' or 'satisfied' with the treatment outcome was 79%, 80%, 75%, 69%, 80%, and 60% (six of 10) at 3 months, 1-, 2-, 3-, 4-, and 5-years, respectively. There were a total of 13 (14%) device failures during the follow-up period.</p><p><strong>Conclusion: </strong>In conclusion, our data suggest that Victo AUS significantly reduces the severity of UI after prostate surgery and provides a reasonably high patient-reported satisfaction with treatment outcomes at mid-term follow-up.</p>","PeriodicalId":8985,"journal":{"name":"BJU International","volume":null,"pages":null},"PeriodicalIF":3.7000,"publicationDate":"2024-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BJU International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/bju.16511","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To report the clinical outcomes of the Victo™ (Promedon, Cordoba, Argentina) adjustable artificial urinary sphincter (AUS) implantation in a cohort of patients with severe urinary incontinence (UI) after prostate surgery.

Patients and methods: This study enrolled patients with UI following prostate surgery who underwent a Victo implantation between May 2018 and December 2023. Patients were prospectively evaluated at baseline, and at 3 and 12 months after device activation, and thereafter annually. The 24-h pad-weight test (24hPWT) was used to assess severity of UI, while the Patient Global Impression of Improvement (PGI-I) and patient satisfaction according to a Likert scale were used to measure patient-reported outcomes.

Results: A total of 96 patients with a median (interquartile range [IQR]) age of 68 (65-72) years were included in the final analysis. The median (IQR) follow-up was 3 (1-4) years. In all, 10 patients completed the 5-year follow-up. After the treatment, we observed a significant reduction in 24hPWT by the median of 83% (P < 0.001) at 3 months and by a median of 79% (P < 0.001) at 3 years. According to the PGI-I, a total of 87%, 92%, 87%, 81%, 83%, and 50% (five of 10) of patients rated their condition/incontinence as 'very much improved', 'much improved' or 'little improved' at 3 months, 1-, 2-, 3-, 4-, and 5-year follow-up visits, respectively. The proportion of patients, who were 'very satisfied' or 'satisfied' with the treatment outcome was 79%, 80%, 75%, 69%, 80%, and 60% (six of 10) at 3 months, 1-, 2-, 3-, 4-, and 5-years, respectively. There were a total of 13 (14%) device failures during the follow-up period.

Conclusion: In conclusion, our data suggest that Victo AUS significantly reduces the severity of UI after prostate surgery and provides a reasonably high patient-reported satisfaction with treatment outcomes at mid-term follow-up.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Victo™ 可调节人工尿道括约肌治疗男性尿失禁的效果。
目的报告在前列腺手术后严重尿失禁(UI)患者队列中植入 Victo™(阿根廷科尔多瓦 Promedon 公司)可调式人工尿道括约肌(AUS)的临床效果:本研究招募了在 2018 年 5 月至 2023 年 12 月期间接受 Victo 植入手术的前列腺术后尿失禁患者。对患者进行了基线、设备激活后 3 个月和 12 个月的前瞻性评估,此后每年进行一次评估。24小时尿垫重量测试(24hPWT)用于评估尿失禁的严重程度,而患者全球改善印象(PGI-I)和患者满意度则根据李克特量表来衡量患者报告的结果:最终分析共纳入96名患者,中位数(四分位数间距[IQR])年龄为68(65-72)岁。随访时间中位数(IQR)为 3(1-4)年。共有 10 名患者完成了为期 5 年的随访。治疗后,我们观察到 24hPWT 显著降低,中位数降低了 83%(P 结论:治疗后,24hPWT 显著降低,中位数降低了 83%):总之,我们的数据表明,Victo AUS 能明显减轻前列腺手术后尿频尿急的严重程度,并且在中期随访中,患者对治疗结果的满意度相当高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BJU International
BJU International 医学-泌尿学与肾脏学
CiteScore
9.10
自引率
4.40%
发文量
262
审稿时长
1 months
期刊介绍: BJUI is one of the most highly respected medical journals in the world, with a truly international range of published papers and appeal. Every issue gives invaluable practical information in the form of original articles, reviews, comments, surgical education articles, and translational science articles in the field of urology. BJUI employs topical sections, and is in full colour, making it easier to browse or search for something specific.
期刊最新文献
A luminal non-coding RNA-based genomic classifier confirms favourable outcomes in patients with clinically organ-confined bladder cancer treated with radical cystectomy. Unravelling the evolution of medical scientific publishing to hold the promise of science for better patient care. An international multicentre randomised controlled trial of en bloc resection of bladder tumour vs conventional transurethral resection of bladder tumour: first results of the en bloc resection of urothelium carcinoma of the bladder (EBRUC) II trial Mortality rates in radical cystectomy patients with bladder cancer after radiation therapy for prostate cancer. Cumulative re‐operation rates during follow‐up after hypospadias repair
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1