{"title":"Increasing the Efficacy of an Air Conditioning Unit by Utilizing Phase Change Material With Cylindrical Configuration","authors":"Arun Kumar Sao,&nbsp;Arun Arora,&nbsp;Mukesh Kumar Sahu","doi":"10.1002/est2.70025","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The goal of the current study is to determine how the SST <span></span><math>\n <semantics>\n <mrow>\n <mi>k</mi>\n <mo>−</mo>\n <mi>ω</mi>\n </mrow>\n <annotation>$$ k-\\omega $$</annotation>\n </semantics></math> and the standard <span></span><math>\n <semantics>\n <mrow>\n <mi>k</mi>\n <mo>−</mo>\n <mi>ɛ</mi>\n </mrow>\n <annotation>$$ k-\\varepsilon $$</annotation>\n </semantics></math> turbulence models prediction on PCM with cylindrical configuration affect AC performance and PCM discharging when coupled with an AC unit. For simulation, 308.15 K and 318.15 K, the inflow air temperature has been considered with a fixed 33.6 L/s intake air flow rate. The low outside temperature charges the PCMs during the night. During the daytime, heated ambient air is cooled by the PCM heat exchanger before passing over the unit condenser. The present outcomes show that using the standard <span></span><math>\n <semantics>\n <mrow>\n <mi>k</mi>\n <mo>−</mo>\n <mi>ε</mi>\n </mrow>\n <annotation>$$ k-\\varepsilon $$</annotation>\n </semantics></math> model, the cylindrical PCM has the lowest time of complete melting. The temperature contours demonstrate that turbulence occurs, particularly at higher temperatures, in the PCM melting zone within the solid region. This implies that there is increased convection in this area. The maximum improved percentage in COP increases as the rising input air temperature for both turbulence models increases. The average power saving of AC at 308.15 K of an input air temperature for 83.33 min is predicted by both the standard <span></span><math>\n <semantics>\n <mrow>\n <mi>k</mi>\n <mo>−</mo>\n <mi>ɛ</mi>\n </mrow>\n <annotation>$$ k-\\varepsilon $$</annotation>\n </semantics></math> and the SST <span></span><math>\n <semantics>\n <mrow>\n <mi>k</mi>\n <mo>−</mo>\n <mi>ω</mi>\n </mrow>\n <annotation>$$ k-\\omega $$</annotation>\n </semantics></math> to be 14.0905 W and 14.1089 W, respectively.</p>\n </div>","PeriodicalId":11765,"journal":{"name":"Energy Storage","volume":"6 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Storage","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/est2.70025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The goal of the current study is to determine how the SST k ω $$ k-\omega $$ and the standard k ɛ $$ k-\varepsilon $$ turbulence models prediction on PCM with cylindrical configuration affect AC performance and PCM discharging when coupled with an AC unit. For simulation, 308.15 K and 318.15 K, the inflow air temperature has been considered with a fixed 33.6 L/s intake air flow rate. The low outside temperature charges the PCMs during the night. During the daytime, heated ambient air is cooled by the PCM heat exchanger before passing over the unit condenser. The present outcomes show that using the standard k ε $$ k-\varepsilon $$ model, the cylindrical PCM has the lowest time of complete melting. The temperature contours demonstrate that turbulence occurs, particularly at higher temperatures, in the PCM melting zone within the solid region. This implies that there is increased convection in this area. The maximum improved percentage in COP increases as the rising input air temperature for both turbulence models increases. The average power saving of AC at 308.15 K of an input air temperature for 83.33 min is predicted by both the standard k ɛ $$ k-\varepsilon $$ and the SST k ω $$ k-\omega $$ to be 14.0905 W and 14.1089 W, respectively.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用圆柱形结构的相变材料提高空调设备的效率
当前研究的目标是确定 SST k - ω $$ k-\omega $$ 和标准 k - ɛ $$ k-\varepsilon $$ 湍流模型对圆柱形结构 PCM 的预测如何影响空调性能以及与空调设备耦合时 PCM 的排出。在模拟时,考虑了 308.15 K 和 318.15 K 的进气温度和固定的 33.6 L/s 进气流速。较低的室外温度会在夜间对 PCM 进行充电。在白天,加热的环境空气在通过机组冷凝器之前被 PCM 热交换器冷却。本研究结果表明,使用标准 k - ε $$ k-\varepsilon $$ 模型,圆柱形 PCM 的完全熔化时间最短。温度等值线表明,在固体区域内的 PCM 熔化区出现了湍流,尤其是在较高温度下。这意味着该区域的对流增加。随着两种湍流模型输入空气温度的升高,COP 的最大改善百分比也在增加。根据标准 k - ɛ $$ k-\varepsilon $$ 和 SST k - ω $$ k-\omega $$ 预测,在输入空气温度为 308.15 K 时,交流电的平均节电时间为 83.33 分钟,分别为 14.0905 W 和 14.1089 W。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
0
期刊最新文献
A System to Store Waste Heat as Liquid Hydrogen Assisted by Organic Rankine Cycle, Proton Exchange Membrane Electrolyzer, and Mixed Refrigerant Hydrogen Liquefaction Cycle Sustainable Hydrogen Storage and Methanol Synthesis Through Solar-Powered Co-Electrolysis Using SOEC Strategic Patent Portfolio Management in the Sodium-Ion Battery Industry: Navigating Innovation and Competition Optimizing Wind and Solar Integration in a Hybrid Energy System for Enhanced Sustainability Exploration of Hydrogen Storage Exhibited by Rh-Decorated Pristine and Defective Graphenes: A First-Principles Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1