Accuracy of Implant Placement Based on Three-Dimensional Preoperative Planning in Total Elbow Arthroplasty.

IF 0.5 Q4 SURGERY Journal of Hand Surgery-Asian-Pacific Volume Pub Date : 2024-10-01 Epub Date: 2024-08-30 DOI:10.1142/S2424835524500450
Tomoki Matsuo, Takuji Iwamoto, Yasuhiro Kiyota, Taku Suzuki, Noboru Matsumura, Kazuki Sato
{"title":"Accuracy of Implant Placement Based on Three-Dimensional Preoperative Planning in Total Elbow Arthroplasty.","authors":"Tomoki Matsuo, Takuji Iwamoto, Yasuhiro Kiyota, Taku Suzuki, Noboru Matsumura, Kazuki Sato","doi":"10.1142/S2424835524500450","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Accurate implant placement in the optimal position is important to obtain favourable clinical outcomes and prevent complications in total joint arthroplasty. We aimed to assess the accuracy of implant placement based on three-dimensional (3D) preoperative planning for unlinked total elbow arthroplasty (TEA) and to clarify the effect of implant placement on clinical outcomes. <b>Methods:</b> This study included 20 patients (22 elbows, 17 with rheumatoid arthritis and 5 with osteoarthritis, with a mean follow-up period of 47 months) who underwent TEA with an unlinked-type implant after computed tomography (CT)-based 3D preoperative planning. Implant placement was planned preoperatively and several parameters were set to reflect it intraoperatively. TEA was performed based on the plan, and postoperative CT was conducted to evaluate differences in implant placement by comparing the preoperative plan and postoperative implant placement. Furthermore, we evaluated the relationship between implant placement differences and postoperative clinical outcomes, including range of motion, Visual Analogue Scale, Mayo Elbow Performance Score 1 year after surgery and complications at the last follow-up. <b>Results:</b> The mean absolute translation was within 2 mm, the mean absolute tilt was within 4°, the mean absolute rotation of the humeral component was within 4° and the mean absolute rotation of the ulnar component was 10.2° ± 6.8°. In the ulnar components, 15/22 (68%) cases were externally rotated, and the mean external rotation was 7.1° ± 10.2°. We defined the absolute ulnar component's rotational difference of more than 10° as a 'malrotation' group (<i>n</i> = 8) and 10° or less as a 'control' group (<i>n</i> = 14). We compared the clinical outcomes between both groups, however, no significant differences were observed in clinical outcomes and complications. <b>Conclusions:</b> We observed notable malrotation in the postoperative positioning of the ulnar component. Intraoperative support devices may be necessary to accurately reproduce the preoperative plan in the surgical field. <b>Level of Evidence:</b> Level IV (Therapeutic).</p>","PeriodicalId":51689,"journal":{"name":"Journal of Hand Surgery-Asian-Pacific Volume","volume":" ","pages":"397-407"},"PeriodicalIF":0.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery-Asian-Pacific Volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S2424835524500450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/30 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Accurate implant placement in the optimal position is important to obtain favourable clinical outcomes and prevent complications in total joint arthroplasty. We aimed to assess the accuracy of implant placement based on three-dimensional (3D) preoperative planning for unlinked total elbow arthroplasty (TEA) and to clarify the effect of implant placement on clinical outcomes. Methods: This study included 20 patients (22 elbows, 17 with rheumatoid arthritis and 5 with osteoarthritis, with a mean follow-up period of 47 months) who underwent TEA with an unlinked-type implant after computed tomography (CT)-based 3D preoperative planning. Implant placement was planned preoperatively and several parameters were set to reflect it intraoperatively. TEA was performed based on the plan, and postoperative CT was conducted to evaluate differences in implant placement by comparing the preoperative plan and postoperative implant placement. Furthermore, we evaluated the relationship between implant placement differences and postoperative clinical outcomes, including range of motion, Visual Analogue Scale, Mayo Elbow Performance Score 1 year after surgery and complications at the last follow-up. Results: The mean absolute translation was within 2 mm, the mean absolute tilt was within 4°, the mean absolute rotation of the humeral component was within 4° and the mean absolute rotation of the ulnar component was 10.2° ± 6.8°. In the ulnar components, 15/22 (68%) cases were externally rotated, and the mean external rotation was 7.1° ± 10.2°. We defined the absolute ulnar component's rotational difference of more than 10° as a 'malrotation' group (n = 8) and 10° or less as a 'control' group (n = 14). We compared the clinical outcomes between both groups, however, no significant differences were observed in clinical outcomes and complications. Conclusions: We observed notable malrotation in the postoperative positioning of the ulnar component. Intraoperative support devices may be necessary to accurately reproduce the preoperative plan in the surgical field. Level of Evidence: Level IV (Therapeutic).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于三维术前规划的全肘关节置换术中植入物放置的准确性
背景:在最佳位置准确植入假体对于获得良好的临床效果和预防全关节成形术并发症非常重要。我们旨在评估基于三维(3D)术前规划的非连接全肘关节置换术(TEA)植入物位置的准确性,并明确植入物位置对临床效果的影响。方法:本研究共纳入了20例患者(22个肘部,其中17例患有类风湿性关节炎,5例患有骨关节炎,平均随访时间为47个月),这些患者在进行了基于计算机断层扫描(CT)的三维术前规划后,使用非连接型假体进行了全肘关节置换术。术前对植入物的位置进行了规划,并在术中设置了若干参数以反映其位置。根据计划进行了 TEA,术后进行了 CT 检查,通过比较术前计划和术后种植体植入情况来评估种植体植入的差异。此外,我们还评估了植入物位置差异与术后临床结果之间的关系,包括活动范围、视觉模拟量表、术后一年的梅奥肘关节表现评分以及最后一次随访时的并发症。结果肱骨组件的平均绝对平移角度在2毫米以内,平均绝对倾斜角度在4°以内,平均绝对旋转角度在4°以内,尺骨组件的平均绝对旋转角度为10.2° ± 6.8°。在尺骨组件中,15/22(68%)个病例外旋,平均外旋角度为 7.1° ± 10.2°。我们将尺骨组件绝对旋转差超过10°的病例定义为 "旋转不良 "组(8例),将10°或10°以下的病例定义为 "对照 "组(14例)。我们比较了两组患者的临床疗效,但在临床疗效和并发症方面未发现明显差异。结论:我们观察到尺骨组件术后定位有明显的错位。术中支持装置可能是在手术区域准确再现术前计划所必需的。证据等级:IV级(治疗)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
304
期刊最新文献
An Algorithm for Management of Radial Longitudinal Deficiency. Camptodactyly. Factors Affecting Appearance after Thumb Polydactyly Reconstruction - A Caregiver's Perspective in an Asian Population. Paediatric Hand Fractures - A Review. Surgical Treatment for Chronic Anterior Dislocation of the Radial Head.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1