Comparison of Thyroid Uptake Values Measured from 131I Scintigraphy and Uptake Probe in Hyperthyroid Patients.

IF 2.9 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL Medical Principles and Practice Pub Date : 2024-09-02 DOI:10.1159/000541147
Nami Yeyin, Sinem Akyol, Lebriz Uslu-Beşli, Mustafa Demir
{"title":"Comparison of Thyroid Uptake Values Measured from 131I Scintigraphy and Uptake Probe in Hyperthyroid Patients.","authors":"Nami Yeyin, Sinem Akyol, Lebriz Uslu-Beşli, Mustafa Demir","doi":"10.1159/000541147","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Thyroid uptake test plays an important role in diagnosis, treatment planning and radioiodine dose determination in patients with hyperthyroidism. The aim of this study was to compare the % uptake values calculated with gamma camera and uptake probe after diagnostic 131I application in hyperthyroid patients.</p><p><strong>Materials and methods: </strong>In this study, % uptake values were measured using a thyroid uptake probe and gamma camera in 32 patients who underwent thyroid radioiodine uptake measurement in our Nuclear Medicine center. Thyroid uptake measurements were prepared in the neck phantom with 0.74-0.925 MBq activity of 131I radionuclide. After counting the phantom with 131I separately in the uptake probe and gamma camera, 131I sample was orally administered to the patient. % uptake values were calculated by the uptake probe measurements and drawing regions of interest (ROI) from scintigraphic images at 2 and 24 h.</p><p><strong>Results: </strong>The 2-h mean % uptake values in the probe and gamma camera were calculated as 30.5 ± 20.4 and 27.1 ± 18.6, respectively. The 24-h mean % uptake values in the thyroid probe and gamma camera were calculated as 57.6 ± 21.9 and 55.3 ± 21.5, respectively. Linear regression analyses for the 2- and 24-h % uptake values calculated with the probe and gamma camera were found as R2 = 0.8412 and R2 = 0.7313, respectively.</p><p><strong>Conclusion: </strong>The 2- and 24-h % uptake values with the probe and gamma camera were found to be consistent with each other, indicating that they can be safely used interchangeably in patients with hyperthyroidism.</p>","PeriodicalId":18455,"journal":{"name":"Medical Principles and Practice","volume":" ","pages":"1-9"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Principles and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000541147","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Thyroid uptake test plays an important role in diagnosis, treatment planning and radioiodine dose determination in patients with hyperthyroidism. The aim of this study was to compare the % uptake values calculated with gamma camera and uptake probe after diagnostic 131I application in hyperthyroid patients.

Materials and methods: In this study, % uptake values were measured using a thyroid uptake probe and gamma camera in 32 patients who underwent thyroid radioiodine uptake measurement in our Nuclear Medicine center. Thyroid uptake measurements were prepared in the neck phantom with 0.74-0.925 MBq activity of 131I radionuclide. After counting the phantom with 131I separately in the uptake probe and gamma camera, 131I sample was orally administered to the patient. % uptake values were calculated by the uptake probe measurements and drawing regions of interest (ROI) from scintigraphic images at 2 and 24 h.

Results: The 2-h mean % uptake values in the probe and gamma camera were calculated as 30.5 ± 20.4 and 27.1 ± 18.6, respectively. The 24-h mean % uptake values in the thyroid probe and gamma camera were calculated as 57.6 ± 21.9 and 55.3 ± 21.5, respectively. Linear regression analyses for the 2- and 24-h % uptake values calculated with the probe and gamma camera were found as R2 = 0.8412 and R2 = 0.7313, respectively.

Conclusion: The 2- and 24-h % uptake values with the probe and gamma camera were found to be consistent with each other, indicating that they can be safely used interchangeably in patients with hyperthyroidism.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
甲状腺摄取值与甲状腺功能亢进症患者通过 131I 闪烁图和摄取探针测量的甲状腺摄取值的比较
目的:甲状腺摄取率检测在甲亢患者的诊断、治疗计划和放射性碘剂量测定中发挥着重要作用。本研究旨在比较甲状腺功能亢进症患者在诊断性应用 131I 后使用伽马相机和摄取探针计算的摄取率值:本研究使用甲状腺摄取探针和伽马相机测量了32名在核医学中心接受甲状腺放射性碘摄取测量的患者的摄取率。甲状腺摄取测量是在颈部模型中使用 0.74-0.925 MBq 活性的 131I 放射性核素进行的。分别在摄取探头和伽马相机中对模型进行131I计数后,给患者口服131I样本。根据摄取探针的测量结果,并在第2小时和第24小时的闪烁扫描图像中绘制感兴趣区(ROI),计算出摄取率值:结果:第2小时探头和伽马相机的平均摄取率分别为30.5±20.4和27.1±18.6。第 24 小时甲状腺探头和伽马相机的平均摄取率分别为 57.6±21.9 和 55.3±21.5。对探头和伽马相机计算出的第2小时和第24小时摄取率值进行线性回归分析,发现R² = 0.8412和R² = 0.7313:结论:使用探针和伽马相机计算的第2小时和第24小时摄取率值是一致的,这表明在甲状腺功能亢进症患者中可以安全地交替使用探针和伽马相机。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medical Principles and Practice
Medical Principles and Practice 医学-医学:内科
CiteScore
6.10
自引率
0.00%
发文量
72
审稿时长
6-12 weeks
期刊介绍: ''Medical Principles and Practice'', as the journal of the Health Sciences Centre, Kuwait University, aims to be a publication of international repute that will be a medium for dissemination and exchange of scientific knowledge in the health sciences.
期刊最新文献
Impact of Sublethal Disinfectant Exposure on Antibiotic Resistance Patterns of Pseudomonas aeruginosa. The Anti-Elixir Triad: Non-Synced Circadian Rhythm, Gut Dysbiosis and Telomeric Damage. Systemic Statin Use and Pulp Chamber Calcification: A Pilot Retrospective Case Control Study Using Cone-Beam Computed Tomography. Endoplasmic Reticular Stress and Pathogenesis of Experimental Colitis: Mechanism of Action of 5-Amino Salicylic Acid. Relative Importance of Defined Mycobacterium Tuberculosis Antigens in the T Cell Recognition Repertoire of Latently Infected Individuals not Progressing to Active Disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1