Biomechanical comparison of two fixation methods for pediatric femoral neck fractures: an in vitro study using ovis aries lambs.

A A Karadeniz, D Topak, F Dogar, A Temiz, O Bilal, B Kuşcu, M Telek
{"title":"Biomechanical comparison of two fixation methods for pediatric femoral neck fractures: an in vitro study using ovis aries lambs.","authors":"A A Karadeniz, D Topak, F Dogar, A Temiz, O Bilal, B Kuşcu, M Telek","doi":"10.26355/eurrev_202408_36666","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In pediatric patients, femoral neck fracture is a relatively rare injury with a high complication rate despite proper diagnosis and treatment. Fixation of femoral neck fractures is usually performed with screws placed along the neck axis. In this study, we aim to compare two different implants and methods in terms of biomechanics.</p><p><strong>Materials and methods: </strong>Twenty-eight right-left fresh femur bones of 6-month-old male Ovis aries lambs grown on the same farm were used. Bones were randomly divided into 4 groups (n=7). In group 1, the Delbet type III femoral neck fracture model was fixed with two 4.5 mm cannulated screws, one screw crossing the physis. In group 2, two 4.5 mm cannulated screws, which did not cross the physis, were used. In group 3, Delbet type III femoral neck fracture model was fixed with a 3.5 mm proximal femoral anatomical plate and five screws, one screw crossing the physis. Finally, in group 4, Delbet type III femoral neck fracture model was fixed with one 3.5 mm proximal femoral anatomical plate and five screws that did not exceed the physis.</p><p><strong>Results: </strong>Biomechanical tests were performed using a Zwick/Roell AllroundLine 100 kN device. While axial failure burden (F = 6.819, p<.05, d = .46) and axial stiffness (F = 3.576, p<.05, d = .30) have been found to be significantly different between the independent treatment groups, axial failure displacement (F = .622, p>.05) and axial failure energy (F = .727, p>.05) have been found not to be significant between the independent groups. The effect sizes of the axial failure load and axial stiffness variables were 0.46 and 0.30, respectively, suggesting a moderate clinical effect. The highest axial failure load was recorded in group 3, while the smallest load was recorded in group 2. Similarly, the axial stiffness level in group 3 was statistically higher than the axial stiffness measurement recorded in group 2, p<.05.</p><p><strong>Conclusions: </strong>Consequently, we found that the biomechanical fixation success was the highest with a 3.5 mm proximal femoral anatomical plate, a 3.5 mm locking screw crossing the physis, and five 3.5 mm screws.</p>","PeriodicalId":12152,"journal":{"name":"European review for medical and pharmacological sciences","volume":"28 16","pages":"4136-4148"},"PeriodicalIF":3.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European review for medical and pharmacological sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.26355/eurrev_202408_36666","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In pediatric patients, femoral neck fracture is a relatively rare injury with a high complication rate despite proper diagnosis and treatment. Fixation of femoral neck fractures is usually performed with screws placed along the neck axis. In this study, we aim to compare two different implants and methods in terms of biomechanics.

Materials and methods: Twenty-eight right-left fresh femur bones of 6-month-old male Ovis aries lambs grown on the same farm were used. Bones were randomly divided into 4 groups (n=7). In group 1, the Delbet type III femoral neck fracture model was fixed with two 4.5 mm cannulated screws, one screw crossing the physis. In group 2, two 4.5 mm cannulated screws, which did not cross the physis, were used. In group 3, Delbet type III femoral neck fracture model was fixed with a 3.5 mm proximal femoral anatomical plate and five screws, one screw crossing the physis. Finally, in group 4, Delbet type III femoral neck fracture model was fixed with one 3.5 mm proximal femoral anatomical plate and five screws that did not exceed the physis.

Results: Biomechanical tests were performed using a Zwick/Roell AllroundLine 100 kN device. While axial failure burden (F = 6.819, p<.05, d = .46) and axial stiffness (F = 3.576, p<.05, d = .30) have been found to be significantly different between the independent treatment groups, axial failure displacement (F = .622, p>.05) and axial failure energy (F = .727, p>.05) have been found not to be significant between the independent groups. The effect sizes of the axial failure load and axial stiffness variables were 0.46 and 0.30, respectively, suggesting a moderate clinical effect. The highest axial failure load was recorded in group 3, while the smallest load was recorded in group 2. Similarly, the axial stiffness level in group 3 was statistically higher than the axial stiffness measurement recorded in group 2, p<.05.

Conclusions: Consequently, we found that the biomechanical fixation success was the highest with a 3.5 mm proximal femoral anatomical plate, a 3.5 mm locking screw crossing the physis, and five 3.5 mm screws.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
小儿股骨颈骨折两种固定方法的生物力学比较:使用羱羊进行的体外研究。
目的:在儿童患者中,股骨颈骨折是一种相对罕见的损伤,尽管诊断和治疗得当,但并发症发生率很高。股骨颈骨折的固定方法通常是沿股骨颈轴线放置螺钉。在这项研究中,我们旨在从生物力学角度对两种不同的植入物和方法进行比较:使用同一农场饲养的 28 只 6 个月大的雄性羊羔的左右新鲜股骨。骨骼随机分为 4 组(n=7)。在第 1 组中,用两枚 4.5 毫米套管螺钉固定 Delbet III 型股骨颈骨折模型,其中一枚螺钉穿过骺端。第 2 组使用两枚 4.5 毫米的套管螺钉,其中一枚螺钉未穿过骺板。第 3 组为 Delbet III 型股骨颈骨折模型,使用 3.5 毫米股骨近端解剖钢板和五枚螺钉固定,其中一枚螺钉穿过骨骺。最后,在第 4 组中,用一块 3.5 毫米股骨近端解剖钢板和五枚螺钉固定 Delbet III 型股骨颈骨折模型,其中一枚螺钉未超过骺板:使用 Zwick/Roell AllroundLine 100 kN 装置进行了生物力学测试。虽然轴向破坏负荷(F = 6.819,p.05)和轴向破坏能量(F = .727,p>.05)在独立组间并不显著。轴向破坏载荷和轴向刚度变量的效应大小分别为 0.46 和 0.30,表明临床效应适中。同样,在统计学上,第 3 组的轴向刚度水平高于第 2 组的轴向刚度测量值,P 结论:因此,我们发现使用 3.5 毫米股骨近端解剖钢板、3.5 毫米锁定螺钉穿过骺端以及五枚 3.5 毫米螺钉的生物力学固定成功率最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.30
自引率
6.10%
发文量
906
审稿时长
2-4 weeks
期刊介绍: European Review for Medical and Pharmacological Sciences, a fortnightly journal, acts as an information exchange tool on several aspects of medical and pharmacological sciences. It publishes reviews, original articles, and results from original research. The purposes of the Journal are to encourage interdisciplinary discussions and to contribute to the advancement of medicine. European Review for Medical and Pharmacological Sciences includes: -Editorials- Reviews- Original articles- Trials- Brief communications- Case reports (only if of particular interest and accompanied by a short review)
期刊最新文献
Comparison of regimens targeting complete remission in the first-line treatment of acute myeloid leukemia patients. Diuretic activity of ethanolic extract and fraction enriched in saponins from Solanum sisymbriifolium Lam. root in rats. Evaluation of adropin level and insulin resistance in non-alcoholic fatty liver patients: a meta-analysis of studies. The possible role of serum NGAL and MMP-9 in the assessment of kidney impairment and cardiovascular risk in children and adolescents with type 1 diabetes mellitus or obesity. Exploring factors influencing COVID-19 severity: a matched case-control study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1