Reliability and agreement of root length measurements during orthodontic treatment in images from different CBCT machines using multiplanar reconstruction.

Biomaterial investigations in dentistry Pub Date : 2024-08-22 eCollection Date: 2024-01-01 DOI:10.2340/biid.v11.41161
Kristina Johansson, Liselotte Paulsson, Helena Christell
{"title":"Reliability and agreement of root length measurements during orthodontic treatment in images from different CBCT machines using multiplanar reconstruction.","authors":"Kristina Johansson, Liselotte Paulsson, Helena Christell","doi":"10.2340/biid.v11.41161","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To assess inter- and intrarater reliability and agreement for measurements of root lengths using multiplanar reconstruction (MPR) in cone beam computed tomography (CBCT) examinations.Furthermore, to determine whether using MPR from different CBCT machines was a reliable and reproducible method for assessment of root length during orthodontic treatment of adolescents.</p><p><strong>Materials and methods: </strong>A total of 40 CBCT examinations obtained before, during and after orthodontic treatment of 14 adolescents, with fixed appliances from a multicentre randomised controlled trial, were used. All roots from the incisors to the first molars were measured by two independent raters and in accordance with a protocol preceded by a multi-step calibration. Reliability was assessed by intra class correlation (ICC). Agreement was assessed by measurement error according to the Dahlberg formula and Bland-Altman plot.</p><p><strong>Results: </strong>The number of repeated measurements varied from 436 to 474 for the different timepoints. Good to excellent inter- and intrarater reliability for different tooth groups and timepoints were shown. Measurement error for inter- and intrarater agreement varied between 0.41 mm and 0.77 mm. The Bland-Altman plot with 95% limits of agreement varied between +1.43 mm and -2.01 mm for different tooth groups and timepoints.</p><p><strong>Conclusions: </strong>The results of this study indicate that CBCT using MPR from different machines is a reproducible method for measuring root length during different phases of orthodontic treatment. When interpreting root shortening measurements in CBCT using MPR for clinical or research purposes, values below 2 mm should be approached with caution, as they may contain measurement errors.</p>","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11371306/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2340/biid.v11.41161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To assess inter- and intrarater reliability and agreement for measurements of root lengths using multiplanar reconstruction (MPR) in cone beam computed tomography (CBCT) examinations.Furthermore, to determine whether using MPR from different CBCT machines was a reliable and reproducible method for assessment of root length during orthodontic treatment of adolescents.

Materials and methods: A total of 40 CBCT examinations obtained before, during and after orthodontic treatment of 14 adolescents, with fixed appliances from a multicentre randomised controlled trial, were used. All roots from the incisors to the first molars were measured by two independent raters and in accordance with a protocol preceded by a multi-step calibration. Reliability was assessed by intra class correlation (ICC). Agreement was assessed by measurement error according to the Dahlberg formula and Bland-Altman plot.

Results: The number of repeated measurements varied from 436 to 474 for the different timepoints. Good to excellent inter- and intrarater reliability for different tooth groups and timepoints were shown. Measurement error for inter- and intrarater agreement varied between 0.41 mm and 0.77 mm. The Bland-Altman plot with 95% limits of agreement varied between +1.43 mm and -2.01 mm for different tooth groups and timepoints.

Conclusions: The results of this study indicate that CBCT using MPR from different machines is a reproducible method for measuring root length during different phases of orthodontic treatment. When interpreting root shortening measurements in CBCT using MPR for clinical or research purposes, values below 2 mm should be approached with caution, as they may contain measurement errors.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用多平面重建技术,在不同 CBCT 设备的图像中测量正畸治疗期间牙根长度的可靠性和一致性。
目的评估在锥形束计算机断层扫描(CBCT)检查中使用多平面重建(MPR)测量牙根长度的内部和外部可靠性和一致性。此外,确定在青少年正畸治疗过程中使用不同CBCT机器的MPR评估牙根长度是否是一种可靠且可重复的方法:研究使用了多中心随机对照试验中为 14 名青少年正畸治疗前、正畸治疗中和正畸治疗后进行的共 40 次 CBCT 检查。从门牙到第一磨牙的所有牙根均由两名独立的评定者按照多步骤校准前的协议进行测量。可靠性通过类内相关性(ICC)进行评估。根据 Dahlberg 公式和 Bland-Altman 图,通过测量误差评估一致性:不同时间点的重复测量次数从 436 次到 474 次不等。不同牙齿组和不同时间点的测量结果表明,测量者之间和测量者内部的可靠性良好到极佳。测量误差介于 0.41 毫米和 0.77 毫米之间。布兰德-阿尔特曼图的 95% 一致性限值在+1.43 毫米和-2.01 毫米之间,适用于不同的牙齿组和时间点:这项研究的结果表明,在正畸治疗的不同阶段,使用不同机器的 MPR 进行 CBCT 是一种可重复的测量牙根长度的方法。当出于临床或研究目的解释使用 MPR 进行的 CBCT 牙根缩短测量值时,应谨慎对待低于 2 毫米的值,因为它们可能包含测量误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
期刊最新文献
Recipient of Biomaterial Investigations in Dentistry's Young Author Award 2023. Reliability and agreement of root length measurements during orthodontic treatment in images from different CBCT machines using multiplanar reconstruction. The sealing ability of different endodontic biomaterials as an intra-orifice barrier: evaluation with high-performance liquid chromatography. An in vitro study on the influence of laser-activated irrigation on infiltration and leakage of a dual curing-resin cement as an endodontic sealer Accumulation and removal of Streptococcus mutans biofilm on enamel and root surfaces in vitro
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1