Improving large angle flow measurement accuracy of five-hole probe using novel calibration coefficient and accuracy progressive neural network

IF 2.3 3区 工程技术 Q2 ENGINEERING, MECHANICAL Flow Measurement and Instrumentation Pub Date : 2024-08-19 DOI:10.1016/j.flowmeasinst.2024.102670
Yueren Zuo , Haideng Zhang , Yun Wu
{"title":"Improving large angle flow measurement accuracy of five-hole probe using novel calibration coefficient and accuracy progressive neural network","authors":"Yueren Zuo ,&nbsp;Haideng Zhang ,&nbsp;Yun Wu","doi":"10.1016/j.flowmeasinst.2024.102670","DOIUrl":null,"url":null,"abstract":"<div><p>Novel calibration coefficients and data-fitting techniques based on a two-stage accuracy progressive neural network were developed to improve the accuracy of a five-hole probe in measuring large-angle flows. By modifying the denominator and numerator of traditional calibration coefficients, the novel coefficients can solve the singularity and multi-value problems of large-angle flow measurement. By training the neural network using both global calibration data and the calibration data of large measurement error points, the two-stage accuracy progressive neural network can effectively improve the measurement accuracy of a five-hole probe when flow separation occurs around the probe head at large flow angles. The experimental results demonstrate that applying the novel calibration coefficients and accuracy progressive neural network ensures that the calibration error of the flow angle is less than 0.8°, and the flow pressure error is less than 0.1 % when the flow angle reaches 50° at low subsonic speeds.</p></div>","PeriodicalId":50440,"journal":{"name":"Flow Measurement and Instrumentation","volume":"99 ","pages":"Article 102670"},"PeriodicalIF":2.3000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Flow Measurement and Instrumentation","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S095559862400150X","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Novel calibration coefficients and data-fitting techniques based on a two-stage accuracy progressive neural network were developed to improve the accuracy of a five-hole probe in measuring large-angle flows. By modifying the denominator and numerator of traditional calibration coefficients, the novel coefficients can solve the singularity and multi-value problems of large-angle flow measurement. By training the neural network using both global calibration data and the calibration data of large measurement error points, the two-stage accuracy progressive neural network can effectively improve the measurement accuracy of a five-hole probe when flow separation occurs around the probe head at large flow angles. The experimental results demonstrate that applying the novel calibration coefficients and accuracy progressive neural network ensures that the calibration error of the flow angle is less than 0.8°, and the flow pressure error is less than 0.1 % when the flow angle reaches 50° at low subsonic speeds.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用新型校准系数和精度递增神经网络提高五孔探头的大角度流量测量精度
为提高五孔探头测量大角度流量的精度,开发了基于两级精度递进神经网络的新型校准系数和数据拟合技术。通过修改传统标定系数的分母和分子,新型系数可以解决大角度流量测量中的奇异性和多值问题。通过使用全局标定数据和大测量误差点的标定数据来训练神经网络,两级精度递增神经网络可以有效提高五孔探头在大流量角度下探头头部周围发生流动分离时的测量精度。实验结果表明,应用新的校准系数和精度渐进神经网络,可确保在低亚音速下,当流动角达到 50°时,流动角的校准误差小于 0.8°,流动压力误差小于 0.1%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Flow Measurement and Instrumentation
Flow Measurement and Instrumentation 工程技术-工程:机械
CiteScore
4.30
自引率
13.60%
发文量
123
审稿时长
6 months
期刊介绍: Flow Measurement and Instrumentation is dedicated to disseminating the latest research results on all aspects of flow measurement, in both closed conduits and open channels. The design of flow measurement systems involves a wide variety of multidisciplinary activities including modelling the flow sensor, the fluid flow and the sensor/fluid interactions through the use of computation techniques; the development of advanced transducer systems and their associated signal processing and the laboratory and field assessment of the overall system under ideal and disturbed conditions. FMI is the essential forum for critical information exchange, and contributions are particularly encouraged in the following areas of interest: Modelling: the application of mathematical and computational modelling to the interaction of fluid dynamics with flowmeters, including flowmeter behaviour, improved flowmeter design and installation problems. Application of CAD/CAE techniques to flowmeter modelling are eligible. Design and development: the detailed design of the flowmeter head and/or signal processing aspects of novel flowmeters. Emphasis is given to papers identifying new sensor configurations, multisensor flow measurement systems, non-intrusive flow metering techniques and the application of microelectronic techniques in smart or intelligent systems. Calibration techniques: including descriptions of new or existing calibration facilities and techniques, calibration data from different flowmeter types, and calibration intercomparison data from different laboratories. Installation effect data: dealing with the effects of non-ideal flow conditions on flowmeters. Papers combining a theoretical understanding of flowmeter behaviour with experimental work are particularly welcome.
期刊最新文献
Simulation and experiment of static and dynamic characteristics of pilot-operated proportional pressure reducing valve Seepage monitoring at variable spatial positions under natural convection with active heating Edge-based intelligent fault diagnosis for centrifugal pumps in microbreweries A review of calibration standards, devices and methods for gas flow in semiconductor manufacturing processes Assessing particle size distribution in suspensions through a multi-frequency ultrasonic backscatter approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1