The mechanical properties measurement could be affected by forceps: a technical note on sampling human annulus fibrosus.

IF 2.6 3区 医学 Q2 CLINICAL NEUROLOGY European Spine Journal Pub Date : 2024-11-01 Epub Date: 2024-09-06 DOI:10.1007/s00586-024-08438-9
Tianchi Zhou, Bowei Xiao, Juying Huang, Tianhua Rong, Bingxuan Wu, Baoge Liu
{"title":"The mechanical properties measurement could be affected by forceps: a technical note on sampling human annulus fibrosus.","authors":"Tianchi Zhou, Bowei Xiao, Juying Huang, Tianhua Rong, Bingxuan Wu, Baoge Liu","doi":"10.1007/s00586-024-08438-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the mechanical properties of human annulus fibrosus obtained by forceps versus bistoury and observe whether the measurement could be affected by forceps sampling method.</p><p><strong>Methods: </strong>In this study, the mechanical properties of the the extracellular matrix (ECM) of human annulus fibrosus, including elastic modulus and stiffness, were investigated using atomic force microscope (AFM). Tissue was obtained from patients during operation using a bistoury or nucleus pulposus forceps. Tissues obtained with the nucleus pulposus forceps were considered as the forceps group and those obtained with a bistoury were considered as the bistoury group.</p><p><strong>Results: </strong>There was no significant difference observed between the forceps and bistoury group according to histological staining. The elastic modulus of the forceps group was 0.41 ± 0.08 MPa, and that of bistoury group was 0.53 ± 0.13 MPa, and the difference between the two groups was statistically significant (p < 0.05). The stiffness of the forceps group was 0.024 ± 0.003 N/m, and that of the bistoury group was 0.037 ± 0.003 N/m, and the difference between the two groups was statistically significant (p < 0.05).</p><p><strong>Conclusion: </strong>The results indicate that the forceps sampling method has a substantial negative effect on the micromechanical properties of the ECM of the annulus fibrosus. Bistoury sampling method is recommended as the experimental subject for exploring the micromechanics mechanisms of cervical degenerative disease.</p>","PeriodicalId":12323,"journal":{"name":"European Spine Journal","volume":" ","pages":"4038-4048"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Spine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00586-024-08438-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the mechanical properties of human annulus fibrosus obtained by forceps versus bistoury and observe whether the measurement could be affected by forceps sampling method.

Methods: In this study, the mechanical properties of the the extracellular matrix (ECM) of human annulus fibrosus, including elastic modulus and stiffness, were investigated using atomic force microscope (AFM). Tissue was obtained from patients during operation using a bistoury or nucleus pulposus forceps. Tissues obtained with the nucleus pulposus forceps were considered as the forceps group and those obtained with a bistoury were considered as the bistoury group.

Results: There was no significant difference observed between the forceps and bistoury group according to histological staining. The elastic modulus of the forceps group was 0.41 ± 0.08 MPa, and that of bistoury group was 0.53 ± 0.13 MPa, and the difference between the two groups was statistically significant (p < 0.05). The stiffness of the forceps group was 0.024 ± 0.003 N/m, and that of the bistoury group was 0.037 ± 0.003 N/m, and the difference between the two groups was statistically significant (p < 0.05).

Conclusion: The results indicate that the forceps sampling method has a substantial negative effect on the micromechanical properties of the ECM of the annulus fibrosus. Bistoury sampling method is recommended as the experimental subject for exploring the micromechanics mechanisms of cervical degenerative disease.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
机械性能测量可能受镊子影响:人体纤维环取样技术说明。
目的:比较用镊子取样和用双套管取样获得的人体纤维环的力学性能,并观察镊子取样方法是否会影响测量结果:本研究使用原子力显微镜(AFM)研究了人纤维环细胞外基质(ECM)的力学特性,包括弹性模量和刚度。组织是在手术过程中使用活瓣钳或髓核钳从患者身上获取的。使用髓核钳获取的组织被视为髓核钳组,使用双镊获取的组织被视为双镊组:结果:根据组织学染色,镊子组和双盘组之间没有明显差异。镊子取样组的弹性模量为 0.41 ± 0.08 MPa,镊子取样组的弹性模量为 0.53 ± 0.13 MPa,两组间差异有统计学意义(P 结论:镊子取样组和镊子取样组的弹性模量差异无统计学意义(P>0.05):结果表明,镊子取样法对纤维环 ECM 的微机械性能有很大的负面影响。建议将 Bistoury 取样法作为探索颈椎退行性疾病微观力学机制的实验对象。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Spine Journal
European Spine Journal 医学-临床神经学
CiteScore
4.80
自引率
10.70%
发文量
373
审稿时长
2-4 weeks
期刊介绍: "European Spine Journal" is a publication founded in response to the increasing trend toward specialization in spinal surgery and spinal pathology in general. The Journal is devoted to all spine related disciplines, including functional and surgical anatomy of the spine, biomechanics and pathophysiology, diagnostic procedures, and neurology, surgery and outcomes. The aim of "European Spine Journal" is to support the further development of highly innovative spine treatments including but not restricted to surgery and to provide an integrated and balanced view of diagnostic, research and treatment procedures as well as outcomes that will enhance effective collaboration among specialists worldwide. The “European Spine Journal” also participates in education by means of videos, interactive meetings and the endorsement of educative efforts. Official publication of EUROSPINE, The Spine Society of Europe
期刊最新文献
Comparison of fusion rate, radiologic and clinical outcome between CaO-SiO2-P2O5-B2O3 bioactive glass-ceramics 7 (BGS-7) spacer and allograft spacer with iliac bone graft in multilevel ACDF. Cross-cultural adaptation, validation, and establishment of the minimal clinicallyimportant change score of the European Portuguese Core Outcome Measures Index in patients with cervical degenerative spine disease. Effect of percutaneous kyphoplasty combined with percutaneous microwave ablation on pain and clinical outcome in patients with spinal metastases. Letter to the editor concerning "association between skin ultrasound parameters and revision surgery after posterior spinal fusion" by E. Chiapparelli, et al. (Eur Spine J [2024]: doi: 10.1007/s00586-024-08319-1). Assessing bone quality in hounsfield units using computed tomography: what value should be used to classify bone as normal or osteoporotic?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1