Focal Volume, Acoustic Radiation Force, and Strain in Two-Transducer Regimes

Kasra Naftchi-Ardebili;Mike D. Menz;Hossein Salahshoor;Gerald R. Popelka;Stephen A. Baccus;Kim Butts Pauly
{"title":"Focal Volume, Acoustic Radiation Force, and Strain in Two-Transducer Regimes","authors":"Kasra Naftchi-Ardebili;Mike D. Menz;Hossein Salahshoor;Gerald R. Popelka;Stephen A. Baccus;Kim Butts Pauly","doi":"10.1109/TUFFC.2024.3456048","DOIUrl":null,"url":null,"abstract":"Transcranial ultrasound stimulation (TUS) holds promise for noninvasive neural modulation in treating neurological disorders. Most clinically relevant targets are deep within the brain (near or at its geometric center), surrounded by other sensitive regions that need to be spared clinical intervention. However, in TUS, increasing frequency with the goal of improving spatial resolution reduces the effective penetration depth. We show that by using a pair of 1-MHz orthogonally arranged transducers, we improve the spatial resolution afforded by each of the transducers individually, by nearly 40 folds, achieving a subcubic millimeter target volume of \n<inline-formula> <tex-math>${0.24}~\\text {mm}^{{3}}$ </tex-math></inline-formula>\n. We show that orthogonally placed transducers generate highly localized standing waves with acoustic radiation force (ARF) arranged into periodic regions of compression and tension near the target. We further present an extended capability of the orthogonal setup, which is to impart selective pressures—either positive or negative, but not both—on the target. Finally, we share our preliminary findings that strain can arise from both particle motion (PM) and ARF with the former reaching its maximum value at the focus and the latter remaining null at the focus and reaching its maximum around the focus. As the field is investigating the mechanism of interaction in TUS by way of elucidating the mapping between ultrasound parameters and neural response, orthogonal transducers expand our toolbox by making it possible to conduct these investigations at much finer spatial resolutions, with localized and directed (compression versus tension) ARF and the capability of applying selective pressures at the target.","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"71 10","pages":"1199-1216"},"PeriodicalIF":3.0000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10669103/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Transcranial ultrasound stimulation (TUS) holds promise for noninvasive neural modulation in treating neurological disorders. Most clinically relevant targets are deep within the brain (near or at its geometric center), surrounded by other sensitive regions that need to be spared clinical intervention. However, in TUS, increasing frequency with the goal of improving spatial resolution reduces the effective penetration depth. We show that by using a pair of 1-MHz orthogonally arranged transducers, we improve the spatial resolution afforded by each of the transducers individually, by nearly 40 folds, achieving a subcubic millimeter target volume of ${0.24}~\text {mm}^{{3}}$ . We show that orthogonally placed transducers generate highly localized standing waves with acoustic radiation force (ARF) arranged into periodic regions of compression and tension near the target. We further present an extended capability of the orthogonal setup, which is to impart selective pressures—either positive or negative, but not both—on the target. Finally, we share our preliminary findings that strain can arise from both particle motion (PM) and ARF with the former reaching its maximum value at the focus and the latter remaining null at the focus and reaching its maximum around the focus. As the field is investigating the mechanism of interaction in TUS by way of elucidating the mapping between ultrasound parameters and neural response, orthogonal transducers expand our toolbox by making it possible to conduct these investigations at much finer spatial resolutions, with localized and directed (compression versus tension) ARF and the capability of applying selective pressures at the target.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
聚焦体积、声辐射力和双换能器状态下的应变。
经颅聚焦超声刺激(TUS)有望用于治疗神经系统疾病的非侵入性神经调节。大多数与临床相关的目标都位于大脑深部(靠近或位于其几何中心),周围还有其他需要避免临床干预的敏感区域。然而,在 TUS 中,为提高空间分辨率而增加频率会降低有效穿透深度。我们的研究表明,通过使用一对正交排列的 1 MHz 换能器,我们将每个换能器单独提供的空间分辨率提高了近 40 倍,实现了 0.24 mm3 的亚立方毫米目标体积。我们的研究表明,正交放置的换能器会产生高度局部的驻波,其声辐射力(ARF)会在目标附近形成周期性的压缩和拉伸区域。我们进一步介绍了正交设置的扩展功能,即对目标施加选择性压力--正压或负压,但不能同时施加。最后,我们分享了我们的初步研究结果,即粒子运动和 ARF 都会产生应变,前者在焦点处达到最大值,后者在焦点处保持为空,并在焦点周围达到最大值。由于该领域正在通过阐明超声参数与神经反应之间的映射关系来研究 TUS 中的相互作用机制,正交传感器扩展了我们的工具箱,使我们有可能在更精细的空间分辨率下进行这些研究,并具有局部和定向(压缩与拉伸)ARF 以及在目标上施加选择性压力的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.70
自引率
16.70%
发文量
583
审稿时长
4.5 months
期刊介绍: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.
期刊最新文献
TinyProbe: A Wearable 32-channel Multi-Modal Wireless Ultrasound Probe. LSMD: Long-Short Memory-Based Detection Network for Carotid Artery Detection in B-mode Ultrasound Video Streams. A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells applied to COVID-19 Patients. High-frequency wearable ultrasound array belt for small animal echocardiography. Deep Power-aware Tunable Weighting for Ultrasound Microvascular Imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1