{"title":"Retrievable dual-chamber leadless pacemaker implant (Aveir DR) in an adult patient with congenital heart disease.","authors":"Howard How-Peng Liu, Daniel Cortez","doi":"10.1016/j.ipej.2024.09.001","DOIUrl":null,"url":null,"abstract":"<p><p>Leadless pacemakers have demonstrated potential as a transvenous pacing option in Adult Congenital Heart Disease patients. Aveir™ single-chamber (VR) leadless pacemakers have demonstrated safety in patients without congenital heart disease in a dual chamber approach. We present a case of dual-chamber pacing using the Aveir dual-chamber (DR) leadless pacemaker in a patient with repaired dextro-transposition of the great arteries with ventricular septal defect (VSD) surgical closure. A 26-year-old male patient with a history of transposition of the great arteries status post arterial switch and VSD repair neonatally had complicated second degree atrioventricular block and sinus node dysfunction necessitating pacemaker placement. Epicardial single-chamber ventricular pacemaker was placed neonatally, which was switched to dual-chamber pacemaker at age 17 due to malfunction. Recent fracture of pacemaker leads led to implantation of new dual chamber leadless pacemaker. Removal of previous pacemaker leads via mechanical extraction occurred and implantation of Aveir DR leadless pacemaker was performed under anesthesia via right femoral vein access without complication. Follow-up demonstrated Aveir VR threshold of 1.0V@0.2 ms, R-wave of 8.9mV, impedance of 490Ω, and the Aveir AR threshold of 0.75V@0.2 ms, P-wave of 3.7mV, and impedance of 400Ω. This case demonstrates safety and efficacy of dual chamber leadless pacemaker implantation in an ACHD patient.</p>","PeriodicalId":35900,"journal":{"name":"Indian Pacing and Electrophysiology Journal","volume":" ","pages":"347-350"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Pacing and Electrophysiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ipej.2024.09.001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Leadless pacemakers have demonstrated potential as a transvenous pacing option in Adult Congenital Heart Disease patients. Aveir™ single-chamber (VR) leadless pacemakers have demonstrated safety in patients without congenital heart disease in a dual chamber approach. We present a case of dual-chamber pacing using the Aveir dual-chamber (DR) leadless pacemaker in a patient with repaired dextro-transposition of the great arteries with ventricular septal defect (VSD) surgical closure. A 26-year-old male patient with a history of transposition of the great arteries status post arterial switch and VSD repair neonatally had complicated second degree atrioventricular block and sinus node dysfunction necessitating pacemaker placement. Epicardial single-chamber ventricular pacemaker was placed neonatally, which was switched to dual-chamber pacemaker at age 17 due to malfunction. Recent fracture of pacemaker leads led to implantation of new dual chamber leadless pacemaker. Removal of previous pacemaker leads via mechanical extraction occurred and implantation of Aveir DR leadless pacemaker was performed under anesthesia via right femoral vein access without complication. Follow-up demonstrated Aveir VR threshold of 1.0V@0.2 ms, R-wave of 8.9mV, impedance of 490Ω, and the Aveir AR threshold of 0.75V@0.2 ms, P-wave of 3.7mV, and impedance of 400Ω. This case demonstrates safety and efficacy of dual chamber leadless pacemaker implantation in an ACHD patient.
期刊介绍:
Indian Pacing and Electrophysiology Journal is a peer reviewed online journal devoted to cardiac pacing and electrophysiology. Editorial Advisory Board includes eminent personalities in the field of cardiac pacing and electrophysiology from Asia, Australia, Europe and North America.